Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Injection analysis

This experiment uses the molybdenum-blue method to determine the concentration of phosphate in a phosphate/sodium chloride mixture. Elow-injection analysis is used to increase the speed of analysis, allowing students to... [Pg.225]

There are many potential advantages to kinetic methods of analysis, perhaps the most important of which is the ability to use chemical reactions that are slow to reach equilibrium. In this chapter we examine three techniques that rely on measurements made while the analytical system is under kinetic rather than thermodynamic control chemical kinetic techniques, in which the rate of a chemical reaction is measured radiochemical techniques, in which a radioactive element s rate of nuclear decay is measured and flow injection analysis, in which the analyte is injected into a continuously flowing carrier stream, where its mixing and reaction with reagents in the stream are controlled by the kinetic processes of convection and diffusion. [Pg.622]

Flow injection analysis (FIA) was developed in the mid-1970s as a highly efficient technique for the automated analyses of samples. °> Unlike the centrifugal analyzer described earlier in this chapter, in which samples are simultaneously analyzed in batches of limited size, FIA allows for the rapid, sequential analysis of an unlimited number of samples. FIA is one member of a class of techniques called continuous-flow analyzers, in which samples are introduced sequentially at regular intervals into a liquid carrier stream that transports the samples to the detector. ... [Pg.649]

Effect of dispersion on a sample s flow profile at different times during a flow injection analysis (a) at injection and when the dispersion is due to (b) convection ... [Pg.650]

A graph showing the detector s response as a function of time in a flow injection analysis. [Pg.650]

Example of a single-channel manifold for use in flow injection analysis where R1 is a reagent reservoir P is the pump S is the sample I is the injector B is a bypass loop ... [Pg.652]

Two examples of dual-channel manifolds for use In flow Injection analysis where R1 and R2 are reagent reservoirs P Is the pump S Is the sample I Is the Injector B Is a bypass loop W Is waste C Is the mixing and reaction coll and D Is the detector. [Pg.653]

Separation Modules Incorporating a separation module in the flow injection manifold allows separations, such as dialysis, gaseous diffusion, and liquid-liquid extraction, to be included in a flow injection analysis. Such separations are never complete, but are reproducible if the operating conditions are carefully controlled. [Pg.653]

Separation module for a flow Injection analysis using a semipermeable membrane for dialysis and gaseous diffusion. [Pg.654]

Separation module for a flow injection analysis using a liquid-liquid extraction (inset shows the equilibrium reaction). [Pg.654]

Source Adapted from Valcarcel, M., Luque de Castro, M. D. Flow-Injection Analysis Principles am ... [Pg.655]

In a quantitative flow injection analysis a calibration curve is determined by injecting standard samples containing known concentrations of analyte. The format of the caK-bration curve, such as absorbance versus concentration, is determined by the method of detection. CaKbration curves for standard spectroscopic and electrochemical methods were discussed in Chapters 10 and 11 and are not considered further in this chapter. [Pg.655]

Flow injection analysis has been applied to a wide variety of samples, including environmental, clinical, agricultural, industrial, and pharmaceutical samples. The majority of analyses to date involve environmental and clinical samples, which is the focus of this section. [Pg.655]

Flow injection analysis has also found numerous applications in the analysis of clinical samples, using both enzymatic and nonenzymatic methods. A list of selected examples is given in Table 13.3. [Pg.656]

The accuracy and precision of FIA are comparable to that obtained by conventional methods of analysis. The precision of a flow injection analysis is influenced by variables that are not encountered in conventional methods, including the stability of the flow rate and the reproducibility of the sample s injection. In addition, results from FIA may be more susceptible to temperature variations. These variables, therefore, must be carefully controlled. [Pg.658]

Finally, FIA is an attractive technique with respect to demands on time, cost, and equipment. When employed for automated analyses, FIA provides for very high sampling rates. Most analyses can be operated with sampling rates of 20-120 samples/h, but rates as high as 1700 samples/h have been realized. Because the volume of the flow injection manifold is small, typically less than 2 mb, consumption of reagents is substantially less than with conventional methods. This can lead to a significant decrease in the cost per analysis. Flow injection analysis requires additional equipment, beyond that used for similar conventional methods of analysis, which adds to the expense of the analysis. On the other hand, flow injection analyzers can be assembled from equipment already available in many laboratories. [Pg.658]

Kinetic methods of analysis are based on the rate at which a chemical or physical process involving the analyte occurs. Three types of kinetic methods are discussed in this chapter chemical kinetic methods, radiochemical methods, and flow injection analysis. [Pg.659]

The following experiments may he used to illustrate the application of kinetic methods of analysis. Experiments are divided into two groups those based on chemical kinetics and those using flow injection analysis. Each suggested experiment includes a brief description. [Pg.659]

The following set of experiments provide examples of the application of flow injection analysis or the characterization of the behavior of a flow injection analysis system. [Pg.660]

Carroll, M. K. Tyson, J. F. An Experiment Using Time-Based Detection in Flow Injection Analysis, /. Chem. Educ. 1993, 70, A210-A216. [Pg.660]

Hansen, E. H. Ruzicka, J. The Principles of Flow Injection Analysis as Demonstrated by Three Lab Exercises, /. Chem. Educ. 1979, 56, 677-680. [Pg.660]

McKelvie, I. D. Cardwell, T. J. Cattrall, R. W. A Microconduit Flow Injection Analysis Demonstration Using a 35-mm Slide Projector, /. Chem. Educ. 1990, 67, 262-263. Directions are provided for constructing a small-scale FIA system that can be used to demonstrate the features of flow injection analysis. For another example see Grudpan, K. Thanasarn, T. Overhead Projector Injection Analysis, Anal. Proc. 1993, 30, 10-12. [Pg.660]

Meyerhoff, M. E. Kovach, P. M. An Ion-Selective Electrode/Flow Injection Analysis Experiment ... [Pg.660]

This experiment describes the adaptation of the bicinchoninic acid (BCA) protein assay to a flow injection analysis. The assay is based on the reduction of Cu + to Cu+ by the protein, followed by the reaction of Cu+ with bicinchoninic acid to form a purple complex that absorbs at 562 nm. Directions are provided for the analysis of bovine serum albumin and rabbit immunoglobulin G, and suggestions are provided for additional analyses. [Pg.660]

A sensitive method for the flow injection analysis of Cu + is based on its ability to catalyze the oxidation of di-2-pyridyl ketone hydrazone (DPKH) by atmospheric oxygen. The product of the reaction is fluorescent and can be used to generate a signal when using a fluorometer as a detector. The yield of the reaction is at a maximum when the solution is made basic with NaOH. The fluorescence, however, is greatest in the presence of HCl. Sketch an FIA manifold that will be appropriate for this analysis. [Pg.663]

The concentration of chloride in sea water can be determined by a flow injection analysis. The analysis of a set of calibration standards gives the results in the following table. [Pg.663]

The following resources provide additional information on the theory and application of flow injection analysis. [Pg.665]

Betteridge, D. Plow Injection Analysis, Anal Chem. 1978, 50, 832A-846A. [Pg.665]

Ruzicka, J. Plow Injection Analysis Prom Test Tube to Integrated Microconduits, Anal Chem. 1983, 55, 1040A-1053A. [Pg.665]

Valcarcel, M. Tuque de Gastro, M. D. Elow-Injection Analysis Principles and Applications, Ellis Horwood Ghichester,... [Pg.665]

Tyson, J. P. Atomic Spectrometry and Plow Injection Analysis A Synergic Gombination, Anal Chim. Acta 1988, 214, 57-75. [Pg.665]

Duarte and colleagues used a factorial design to optimize a flow injection analysis method for determining penicillin potentiometricallyd Three factors were studied—reactor length, carrier flow rate, and sample volume, with the high and low values summarized in the following table. [Pg.702]


See other pages where Injection analysis is mentioned: [Pg.649]    [Pg.649]    [Pg.649]    [Pg.650]    [Pg.655]    [Pg.658]    [Pg.659]    [Pg.663]    [Pg.772]    [Pg.772]    [Pg.774]   


SEARCH



A sensitive micellar-enhanced chemiluminescence method for the determination of ofloxacin by flow injection analysis

Also Flow injection analysis)

Amino acids flow-injection analysis

Analysis of Digested Rock Samples Using Flow Injection

Analysis of Digested Rock Samples Using Flow Injection (FI)

Analytical methods flow-injection analysis

Anionic species, flow injection analysis

Automated flow injection analysis

Automation approaches flow injection analysis

Bands flow-injection analysis

Batch Injection Analysis Principles

Batch injection analysis

Batch injection analysis amperometric detection

Bioprocesses flow injection analysis

Calibration flow-injection analysis systems

Carbon dioxide flow injection analysis

Chemical oxygen demand flow injection analysis

Continuous analysers flow-injection analysis

Cooling injection molding analysis

Cross-injection analysis

Cytochrome flow injection analysis

Detection limits flow injection analysis

Detector in flow injection analysis

Detectors, flow-injection analysis

Direct injection analysis

Dispersion flow-injection analysis

Dissolved flow injection analysis

ECL Coupled with Flow Injection Analysis

Electrochemical batch injection analysis

FIA—See Flow-injection analysis

FLOW INJECTION ANALYSIS NOW AND IN THE FUTURE

Features of flow-injection analysis

Fiber-optic flow-injection analysis

Flow Injection Analysis and Atomic Spectrometry

Flow injection analysis

Flow injection analysis , electrochemical detection

Flow injection analysis MS

Flow injection analysis advantages

Flow injection analysis amperometric detector

Flow injection analysis applications

Flow injection analysis automated system, formaldehyde

Flow injection analysis biosensor

Flow injection analysis carrier stream

Flow injection analysis channel length

Flow injection analysis characteristics

Flow injection analysis conventional electrodes

Flow injection analysis devices

Flow injection analysis dispersion coefficient

Flow injection analysis element selective detectors

Flow injection analysis evaluation

Flow injection analysis films

Flow injection analysis fluorescent derivatives

Flow injection analysis formaldehyde

Flow injection analysis management

Flow injection analysis methods

Flow injection analysis micro-systems

Flow injection analysis natural water samples

Flow injection analysis on-line

Flow injection analysis recording

Flow injection analysis riboflavin

Flow injection analysis sample volume

Flow injection analysis sample volume influence

Flow injection analysis sample volume study

Flow injection analysis schematic diagram

Flow injection analysis screen-printed electrodes

Flow injection analysis sensitive detectors

Flow injection analysis system characterization

Flow injection analysis system configuration

Flow injection analysis system supervision

Flow injection analysis systems

Flow injection analysis theory

Flow injection analysis voltammetric detection

Flow injection analysis with hydride generation

Flow injection analysis, FIA

Flow injection analysis, advances

Flow injection analysis, solid

Flow injection analysis-direct current

Flow injection analysis: potentiometric

Flow injection analysis: potentiometric sensors

Flow-Injection Analysis with Electrochemical Detection

Flow-injection analysis amino acids, detection limit

Flow-injection analysis apparatus

Flow-injection analysis detection systems

Flow-injection analysis determination

Flow-injection analysis field applications

Flow-injection analysis for

Flow-injection analysis immunoassays with

Flow-injection analysis peak effects

Flow-injection analysis principles

Flow-injection analysis propelling systems

Flow-injection analysis refractive index effect

Flow-injection analysis reproducibility

Flow-injection analysis reverse

Flow-injection analysis sample dispersion

Flow-injection analysis sampling error

Flow-injection analysis system, schematic

Flow-injection analysis technique

Flow-injection analysis trends

Flow-injection analysis-mass spectrometry

Flow-injection analysis-mass spectrometry FIA-MS)

Flow-injection analysis-mass spectrometry applications

Flow-injection analysis-mass spectrometry compounds

Flow-injection analysis-mass spectrometry gemini surfactants

Flux injection analysis

Foundation of flow-injection analysis

Injectable dosage forms , analysis

Integrated flow injection analysis

Iron flow injection analysis

Lab-on-valve Flow Injection Analysis

Modified FIAS-400 flow injection analysis

Modular flow-injection analysis

Multichannel flow injection analysis

Multisyringe flow injection analysis

Nitrate flow-injection analysis

Nitrite flow-injection analysis

Phosphate determination reverse flow-injection analysis

Phosphate flow-injection analysis

Poly -modified electrode, flow injection analysis

Probe flow injection analysis

Quantitative Analysis Using Flow Injection Technique

Quantitative analysis flow injection technique

Sample introduction systems flow injection analysis

Sample preparation flow injection analysis

Sequential injection analysis

Sequential injection analysis principles

Sequential injection analysis systems

Slow injection analysis

© 2024 chempedia.info