Mopper, K., Stubbins, A., Ritchie, J. D., Bialk, H. M., and Hatcher, P G. (2007). Advanced instrumental approaches for characterization of marine dissolved organic matter Extraction techniques, mass spectrometry, and nuclear magnetic resonance spectroscopy. Chem. Rev. 107,419-442. [Pg.447]

The measurement of equilibrium constants is a crucial aspect in lanthanide and actinide chemistry. Several techniques are available for such determination (spectrophotometry, potentiom-etry, solvent extraction, electrospray mass-spectrometry,. ..), among which TRES is commonly used in the case of reaction studies of luminescent lanthanides with organic ligands (Richardson, 1982 Parker and Williams, 1996). The high sensitivity of TRES (see sect. 6) allows quantitative measurements of very dilute solutions, which facilitates the handling of highly radioactive materials such as Cm. [Pg.493]

See also Air Analysis Sampling. Extraction Solvent Extraction Multistage Countercurrent Distribution Supercritical Fluid Extraction. Gas Chromatography Multidimensional Techniques. Mass Spectrometry Time-of-Flight. Quality Assurance Quality Control Reference Materials. Water Analysis Overview. [Pg.858]

See also Extraction Solvent Extraction Principles. Gas Chromatography Multidimensional Techniques Mass Spectrometry. Lipids Overview. Quaiity Assurance ... [Pg.3774]

Coverage includes B vitamins and folate in the context of a historical background, disease, cardiovascular effects and the importance of vitamins in biochemistry as illustrated by a single vitamin. Thereafter there are chapters on the chemistry and biochemistry of thiamine, riboflavin, niacin, pantothenic acid, pyridoxine, biotin, folate and cobalamin. Methodical aspects include characterization and assays of B vitamins and folate in foods of all kinds, dietary supplements, biological fluids and tissues. The techniques cover solid-phase extraction, spectrofluorimetry, mass spectrometry, HPLC, enzymatic assay, biosensor and chemiluminescence. In terms of fimction and effects or... [Pg.5]

This particular problem of analysing the reference standard correctly should not be underestimated. If all parties involved In a transaction agree on a particular set of figures for the reference extract, it does not matter vithether the figures are absolutely correct or not, but if the exact alpha acids content has to be known, then the difficulties start. Extravagant claims have been circulated in the field that some reference standards were analysed by quantitative mass spectrometry. People who are not familiar with mass spectrometry will believe this, since they will assume that results obtained with such a sophisticated technique should be correct. Of all modern analytical techniques, mass spectrometry is, however, one of the weakest on quantification. Such situations are clearly the result of clashing commercial interests and scientific possibilities. [Pg.342]

Quantitative mass spectrometry, also used for pharmaceutical appHcations, involves the use of isotopicaHy labeled internal standards for method calibration and the calculation of percent recoveries (9). Maximum sensitivity is obtained when the mass spectrometer is set to monitor only a few ions, which are characteristic of the target compounds to be quantified, a procedure known as the selected ion monitoring mode (sim). When chlorinated species are to be detected, then two ions from the isotopic envelope can be monitored, and confirmation of the target compound can be based not only on the gc retention time and the mass, but on the ratio of the two ion abundances being close to the theoretically expected value. The spectrometer cycles through the ions in the shortest possible time. This avoids compromising the chromatographic resolution of the gc, because even after extraction the sample contains many compounds in addition to the analyte. To increase sensitivity, some methods use sample concentration techniques. [Pg.548]

The use of separation techniques, such as gel permeation and high pressure Hquid chromatography interfaced with sensitive, silicon-specific aas or ICP detectors, has been particularly advantageous for the analysis of siUcones in environmental extracts (469,483—486). Supercritical fluid chromatography coupled with various detection devices is effective for the separation of siUcone oligomers that have molecular weights less than 3000 Da. Time-of-flight secondary ion mass spectrometry (TOF-sims) is appHcable up to 10,000 Da (487). [Pg.60]

The liquid chromatography - tandem mass spectrometry (LC/MS/MS) technique was proposed for the determination of corticosteroids in plasma and cerebrospinal fluid (CSF, liquor) of children with leucosis. Preliminai y sample prepai ation included the sedimentation of proteins, spinning and solid-phase extraction. MS detection was performed by scanning selected ions, with three chai acteristic ions for every corticosteroids. The limit of detection was found 80 pg/ml of plasma. [Pg.351]

Other technique—for example, dynamic secondary ion mass spectrometry or forward recoil spectrometry—that rely on mass differences can use the same type of substitution to provide contrast. However, for hydrocarbon materials these methods attain a depth resolution of approximately 13 nm and 80 nm, respectively. For many problems in complex fluids and in polymers this resolution is too poor to extract critical information. Consequently, neutron reflectivity substantially extends the depth resolution capabilities of these methods and has led, in recent years, to key information not accessible by the other techniques. [Pg.660]

Multidimensional gas chromatography has also been used in the qualitative analysis of contaminated environmental extracts by using spectral detection techniques Such as infrared (IR) spectroscopy and mass spectrometry (MS) (20). These techniques produce the most reliable identification only when they are dealing with pure substances this means that the chromatographic process should avoid overlapping of the peaks. [Pg.337]

In order to reduce or eliminate off-line sample preparation, multidimensional chromatographic techniques have been employed in these difficult analyses. LC-GC has been employed in numerous applications that involve the analysis of poisonous compounds or metabolites from biological matrices such as fats and tissues, while GC-GC has been employed for complex samples, such as arson propellants and for samples in which special selectivity, such as chiral recognition, is required. Other techniques include on-line sample preparation methods, such as supercritical fluid extraction (SFE)-GC and LC-GC-GC. In many of these applications, the chromatographic method is coupled to mass spectrometry or another spectrometiic detector for final confirmation of the analyte identity, as required by many courts of law. [Pg.407]

Structure determination of luciferin. Once a luciferin is obtained in a sufficient purity, the determination of luciferin structure should be attempted most of the important properties of luciferin are usually already obtained during the course of purification as a necessity. The structural study is considerably more straightforward than the extraction and purification, due to the availability of advanced methods, such as high-resolution mass spectrometry and various NMR techniques. If help or collaboration is needed in structure determination, the attractiveness of a luciferin will make it easy to find a good collaborator. However, the purified luciferin is usually an extremely precious material considering the effort spent in preparing it. To avoid accidental loss of the purified material, the chosen collaborator must have solid knowledge and experience in structure determination a criterion to be considered is that the person has successfully done the structure determination of at least one new natural product. [Pg.377]

A new technique has been developed to analyze a- and (3-endosulfan concentrations in human urine (Vidal et al. 1998). Samples are mixed with a buffer solution and then passed through solid phase extraction cartridges for analysis using gas chromatography-tandem mass spectrometry (GC-MS-MS). [Pg.249]

The choice of the method of analysis depends on the question to address. Spectrophotometry is sufficient for total curcuminoid content determination in a turmeric extract. Separation techniques coupled to mass spectrometry detection and MALDl-TOF are highly sensitive techniques that are more adapted to the identification of metabolites in biological fluids such as urine or plasma. ... [Pg.79]

High performance spectroscopic methods, like FT-IR and NIR spectrometry and Raman spectroscopy are widely applied to identify non-destructively the specific fingerprint of an extract or check the stability of pure molecules or mixtures by the recognition of different functional groups. Generally, the infrared techniques are more frequently applied in food colorant analysis, as recently reviewed. Mass spectrometry is used as well, either coupled to HPLC for the detection of separated molecules or for the identification of a fingerprint based on fragmentation patterns. ... [Pg.523]

A further extension of the DFG S19 method was achieved when polar analytes and those unsuitable for GC were determined by LC/MS or more preferably by liquid chromatography/tandem mass spectrometry (LC/MS/MS). Triple-quadrupole MS/MS and ion trap MS" have become more affordable and acceptable in the recent past. These techniques provide multiple analyte methods by employing modes such as time segments, scan events or multiple injections. By improving the selectivity and sensitivity of detection after HPLC separation, the DFG S19 extraction and cleanup scheme can be applied to polar or high molecular weight analytes, and cleanup steps such as Si02 fractionation or even GPC become unnecessary. [Pg.57]

Analytical methods for parent chloroacetanilide herbicides in soil typically involve extraction of the soil with solvent, followed by solid-phase extraction (SPE), and analysis by gas chromatography/electron capture detection (GC/ECD) or gas chromatog-raphy/mass spectrometry (GC/MS). Analytical methods for parent chloroacetanilides in water are similarly based on extraction followed by GC with various detection techniques. Many of the water methods, such as the Environmental Protection Agency (EPA) official methods, are multi-residue methods that include other compound classes in addition to chloroacetanilides. While liquid-liquid partitioning was used initially to extract acetanilides from water samples, SPE using... [Pg.345]

All previous discussion has focused on sample preparation, i.e., removal of the targeted analyte(s) from the sample matrix, isolation of the analyte(s) from other co-extracted, undesirable sample components, and transfer of the analytes into a solvent suitable for final analysis. Over the years, numerous types of analytical instruments have been employed for this final analysis step as noted in the preceding text and Tables 3 and 4. Overall, GC and LC are the most often used analytical techniques, and modern GC and LC instrumentation coupled with mass spectrometry (MS) and tandem mass spectrometry (MS/MS) detection systems are currently the analytical techniques of choice. Methods relying on spectrophotometric detection and thin-layer chromatography (TLC) are now rarely employed, except perhaps for qualitative purposes. [Pg.439]

Specifically for triazines in water, multi-residue methods incorporating SPE and LC/MS/MS will soon be available that are capable of measuring numerous parent compounds and all their relevant degradates (including the hydroxytriazines) in one analysis. Continued increases in liquid chromatography/atmospheric pressure ionization tandem mass spectrometry (LC/API-MS/MS) sensitivity will lead to methods requiring no aqueous sample preparation at all, and portions of water samples will be injected directly into the LC column. The use of SPE and GC or LC coupled with MS and MS/MS systems will also be applied routinely to the analysis of more complex sample matrices such as soil and crop and animal tissues. However, the analyte(s) must first be removed from the sample matrix, and additional research is needed to develop more efficient extraction procedures. Increased selectivity during extraction also simplifies the sample purification requirements prior to injection. Certainly, miniaturization of all aspects of the analysis (sample extraction, purification, and instrumentation) will continue, and some of this may involve SEE, subcritical and microwave extraction, sonication, others or even combinations of these techniques for the initial isolation of the analyte(s) from the bulk of the sample matrix. [Pg.445]

The need to understand the fate of pesticides in the environment has necessitated the development of analytical methods for the determination of residues in environmental media. Adoption of methods utilizing instrumentation such as gas chro-matography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS), liquid chromatography/tandem mass spectrometry (LC/MS/MS), or enzyme-linked immunosorbent assay (ELISA) has allowed the detection of minute amounts of pesticides and their degradation products in environmental samples. Sample preparation techniques such as solid-phase extraction (SPE), accelerated solvent extraction (ASE), or solid-phase microextraction (SPME) have also been important in the development of more reliable and sensitive analytical methods. [Pg.605]

The development of a robust analytical method is a complex issue. The residue analyst has available a vast array of techniques to assist in this task, but there are a number of basic rules that should be followed to produce a reliable method. The intention of this article is to provide the analyst with ideas from which a method can be constructed by considering each major component of the analytical method (sample preparation, extraction, sample cleanup, and the determinative step), and to suggest modern techniques that can be used to develop an effective and efficient overall approach. The latter portion emphasizes mass spectrometry (MS) since the current trend for pesticide residue methods is leading to MS becoming the method of choice for simultaneous quantitation and confirmation. This article also serves to update previous publications on similar topics by the authors. ... [Pg.753]

The most common final separation techniques used for agrochemicals are GC and LC. A variety of detection methods are used for GC such as electron capture detection (BCD), nitrogen-phosphorus detection (NPD), flame photometric detection (FPD) and mass spectrometry (MS). For LC, typical detection methods are ultraviolet (UV) detection, fluorescence detection or, increasingly, different types of MS. The excellent selectivity and sensitivity of LC/MS/MS instruments results in simplified analytical methodology (e.g., less cleanup, smaller sample weight and smaller aliquots of the extract). As a result, this state-of-the-art technique is becoming the detection method of choice in many residue analytical laboratories. [Pg.878]

This procedure was compared with sequential extractive techniques employing alkaline hydrolysis of dried plant tissue followed by extraction of the acidified mixture with ethyl acetate. Fractions were individually evaluated for phytotoxic properties. Selected fractions from those showing a positive response were analyzed by gas-liquid chromatography. Structural identification and characterization of the individual components in these selected fractions were accomplished by gas chromatography-mass spectrometry. [Pg.99]


See other pages where Extraction technique mass spectrometry is mentioned: [Pg.391]    [Pg.114]    [Pg.343]    [Pg.391]    [Pg.444]    [Pg.277]    [Pg.533]    [Pg.430]    [Pg.323]    [Pg.407]    [Pg.45]    [Pg.7]    [Pg.412]    [Pg.525]    [Pg.204]    [Pg.206]    [Pg.25]    [Pg.346]    [Pg.442]    [Pg.734]    [Pg.736]    [Pg.851]    [Pg.25]   