Finally, other methods are used to obtain simulated distillation by gas phase chromatography for atmospheric or vacuum residues. For these cases, some of the sample components can not elute and an internal standard is added to the sample in order to obtain this quantity with precision. [Pg.23]

In principle, DSI is the simplest method for sample introduction into a plasma torch since the sample is placed into the base of the flame, which then heats, evaporates, and ionizes the sample, all in one small region. Inherent sensitivity is high because the sample components are already in the flame. A diagrammatic representation of a DSI assembly is shown in Figure 17.4. [Pg.114]

Reversed-phase columns are used to separate polar substances. Although in LC the stationary phase is a solid, it is necessary to bear in mind that there may be a thin film of liquid (e.g water) held on its surface, and this film will modify the behavior of sample components equilibrating between the mobile and stationary phases. A textbook on LC should be consulted for deeper discussion on such aspects. [Pg.250]

In some inlet devices, the volatile sample materials are first separated from entrained hydrogen gas or air by condensing them in a coolant bath. Subsequently, when all of the volatile sample components have been condensed and the hydrogen or air has been swept away, the sample is reheated and sent to the plasma flame. [Pg.396]

Dynamic headspace GC/MS. The distillation of volatile and semivolatile compounds into a continuously flowing stream of carrier gas and into a device for trapping sample components. Contents of the trap are then introduced onto a gas chromatographic column. This is followed by mass spectrometric analysis of compounds eluting from the gas chromatograph. [Pg.432]

Because they are weak acids or bases, the iadicators may affect the pH of the sample, especially ia the case of a poorly buffered solution. Variations in the ionic strength or solvent composition, or both, also can produce large uncertainties in pH measurements, presumably caused by changes in the equihbria of the indicator species. Specific chemical reactions also may occur between solutes in the sample and the indicator species to produce appreciable pH errors. Examples of such interferences include binding of the indicator forms by proteins and colloidal substances and direct reaction with sample components, eg, oxidising agents and heavy-metal ions. [Pg.468]

Immunoassays. Immunoassays (qv) maybe simply defined as analytical techniques that use antibodies or antibody-related reagents for selective deterrnination of sample components (94). These make up some of the most powerflil and widespread techniques used in clinical chemistry. The main advantages of immunoassays are high selectivity, low limits of detection, and adaptibiUty for use in detecting most compounds of clinical interest. Because of their high selectivity, immunoassays can often be used even for complex samples such as urine or blood, with Httle or no sample preparation. [Pg.247]

Column Tubing. The chromatographic column is contained in a tubing, the composition of which may have a dramatic effect on the separation process, because the sample components may also interact with the walls of the tube. Some of the materials used for columns are... [Pg.107]

Under certain conditions the sample is clearly visible throughout the process. Other times it is necessary to stain the matrix to visualize the components. In cases where a final staining procedure is required, a small amount of dye is often added to the sample before the analysis. The dye typically migrates faster than any sample component. The position of the dye in the matrix indicates the speed of the resolution of the components of the sample. Typically, the electrophoretic medium is discarded after use. Good resolution can be obtained from 1 to 20 hours, using applied voltages of 10 to 2000 V and currents of 5 to 100 m A. [Pg.180]

Disc Electrophoresis. Resolution in zone electrophoresis depends critically on getting sample components to migrate in a focused band, thus some techniques ate employed to concentrate the sample as it migrates through the gel. The most common technique is referred to as discontinuous pH or disc electrophoresis. Disc electrophoresis employs a two-gel system, where the properties of the two gels are different. [Pg.180]

Capillary Electrophoresis. Capillaries were first appHed as a support medium for electrophoresis in the early 1980s (44,45). The glass capillaries used are typically 20 to 200 p.m in diameter (46), may be filled with buffer or gel, and are frequendy coated on the inside. Capillaries are used because of the high surface-to-volume ratio which allows high voltages without heating effects. The only limitations associated with capillaries are limits of detection and clearance of sample components. [Pg.183]

Most sample components analyzed with electrophoretic techniques are invisible to the naked eye. Thus methods have been developed to visualize and quantify separated compounds. These techniques most commonly involve chemically fixing and then staining the compounds in the gel. Other detection techniques can sometimes yield more information, such as detection using antibodies to specific compounds, which gives positive identification of a sample component either by immunoelectrophoretic or blotting techniques, or enhanced detection by combining two different electrophoresis methods in two-dimensional electrophoretic techniques. [Pg.183]

A number of composition analyzers used for process monitoring and control require chemical conversion of one or more sample components preceding quantitative measurement. These reactions include... [Pg.764]

The resolution required in any analytical SEC procedure, e.g., to detect sample impurities, is primarily based on the nature of the sample components with respect to their shape, the relative size differences of species contained in the sample, and the minimal size difference to be resolved. These sample attributes, in addition to the range of sizes to be examined, determine the required selectivity. Earlier work has shown that the limit of resolvability in SEC of molecules [i.e., the ability to completely resolve solutes of different sizes as a function of (1) plate number, (2) different solute shapes, and (3) media pore volumes] ranges from close to 20% for the molecular mass difference required to resolve spherical solutes down to near a 10% difference in molecular mass required for the separation of rod-shaped molecules (Hagel, 1993). To approach these limits, a SEC medium and a system with appropriate selectivity and efficiency must be employed. [Pg.30]

The right chromatography column should separate the sample sufficiently to enable identification or quantitative measurement of the components within a reasonable period of time. The resolution factor (Rs) for two sample components is determined by the width of the two peaks and the distance between the peak maxima. In general, Rs values of 1.0 are required for good qualitative or quantitative work, whereas Rs values >1.5 indicate baseline resolution for two components (3). [Pg.94]

A standard test probe is not absolutely necessary to monitor the column. Any well-resolved peak in the sample may be used. To use a sample component, baseline data must be established when the column is new and performing well. After establishing that the column is performing properly using the manufacturer s standard test procedure, calculate the assymetry factor, theoretical plates, and resolution of one or more of the sample components. Also note the retention time. This will become the baseline test mix, which will be used for later comparison. [Pg.134]

Characteristics due to chemical functionalities (e.g., carboxyl groups) of sample components that control solubility of the sample in aqueous media, viscosity of carbohydrate/polysaccharide solutions, and stability of obtained solutions. [Pg.460]

Interactions in the ternary system sample components eluent/SEC matrix. [Pg.460]

Each of the three fractions was applied to a combined SEC system of Fractogel/Superose to investigate their molecular characteristics in detail. These high resolution and mechanically stable gels allow the application of eluents with increased ionic strengths (e.g., 0.05 M KCl) at a reasonable resolution of sample components (Fig. 16.15). [Pg.477]

Giddings pointed out (32) that separated compounds must remain resolved throughout the whole process. This situation is illustrated in Figure 1.5, where two secondary columns are coupled to a primary column, and each secondary column is fed a fraction of duration Ar from the eluent from the first column. The peak capacity of the coupled system then depends on the plate number of each individual separation and on At. The primary column eliminates sample components that would otherwise interfere with the resolution of the components of interest in the secondary columns. An efficient primary separation may be wasted, however, if At is greater than the average peak width produced by the primary column, because of the recombination of resolved peaks after transfer into a secondary column. As At increases, the system approaches that of a tandem arrangement, and the resolution gained in one column may be nullified by the elution order in a subsequent column. [Pg.10]

S. Wu, W. H. Chatham and S. O. Farwell, Multidimensional HRGC for sample components with a wide range of volatilities and polarities , J. High Resolut. Chromatogr. 13 229-233 (1990). [Pg.73]

As described above, resolution can be improved by variations in plate number, selectivity or capacity factor. However, when considering the separation of a mixture which contains several components of different retention rates, the adjustment of the capacity factors has a limited influence on resolution. The retention times for the last eluted peaks can be excessive, and in some cases strongly retained sample components would not be eluted at all. [Pg.112]

An example of the results obtained in the form of a chromatoelectropherogram can be seen in Figure 9.6. The contour type data display showed the three variables that were studied, namely chromatographic elution time, electrophoretic migration time, and relative absorbance intensity. Peptides were cleanly resolved by using this two-dimensional method. Neither method alone could have separated the analytes under the same conditions. The most notable feature of this early system was that (presumably) all of the sample components from the first dimension were analyzed by the second dimension, which made this a truly comprehensive multidimensional technique. [Pg.205]

Multi-column switching can be an effective approach for the determination of high and low concentrations of sample components in complex mixtures. This is a very powerful technique for the analytical and preparative separation of components... [Pg.319]

The column. The actual separation of sample components is effected in the column where the nature of the solid support, type and amount of liquid phase, method of packing, length and temperature are important factors in obtaining the desired resolution. [Pg.238]


See other pages where Sample component is mentioned: [Pg.97]    [Pg.568]    [Pg.277]    [Pg.48]    [Pg.90]    [Pg.40]    [Pg.317]    [Pg.109]    [Pg.110]    [Pg.180]    [Pg.181]    [Pg.182]    [Pg.183]    [Pg.765]    [Pg.766]    [Pg.445]    [Pg.8]    [Pg.34]    [Pg.35]    [Pg.124]    [Pg.141]    [Pg.460]    [Pg.290]    [Pg.299]    [Pg.305]    [Pg.222]   
See also in sourсe #XX -- [ Pg.16 ]




SEARCH



Adhesive component samples

Adhesive component samples commercial

Elution of Sample Components

Identification of sample components

Improved Reactor Sampling Using NeSSI Components

Principal component analysis Sample handling

Processing Case Study Estimating Abundance of Sample Components

Sample Protein Components

Sample component identification

Sample components, separation

Sample excitation components

Sample, multi-component

Sample, multi-component characterization

Samples volatile components

Sampling system components

Terms Referring to Sample Component Separation

© 2024 chempedia.info