Sample preparation spectrometry

Gold is a useflil caUbration standard for this method (see Radioactive tracers). Whereas similar sensitivities can be achieved by inductively coupled plasma mass spectrometry (qv), the latter requires more extensive sample preparation to overcome interference by other metals such as copper (64). [Pg.381]

The very low Hg concentration levels in ice core of remote glaciers require an ultra-sensitive analytical technique as well as a contamination-free sample preparation methodology. The potential of two analytical techniques for Hg determination - cold vapour inductively coupled plasma mass spectrometry (CV ICP-SFMS) and atomic fluorescence spectrometry (AFS) with gold amalgamation was studied. [Pg.171]

The complex of the following destmctive and nondestmctive analytical methods was used for studying the composition of sponges inductively coupled plasma mass-spectrometry (ICP-MS), X-ray fluorescence (XRF), electron probe microanalysis (EPMA), and atomic absorption spectrometry (AAS). Techniques of sample preparation were developed for each method and their metrological characteristics were defined. Relative standard deviations for all the elements did not exceed 0.25 within detection limit. The accuracy of techniques elaborated was checked with the method of additions and control methods of analysis. [Pg.223]

I. Eeirer, V. Pichon, M. C. Hennion and D. Barcelo, Automated sample preparation with exti action columns by means of anti-isoproturon immunosorbents for the determination of phenylurea herbicides in water followed by liquid chi omatography diode array detection and liquid clrromatogi aphy-atmospheric pressure chemical ionization mass spectrometry , 7. Chromatogr. Ill 91-98 (1997). [Pg.375]

In order to reduce or eliminate off-line sample preparation, multidimensional chromatographic techniques have been employed in these difficult analyses. LC-GC has been employed in numerous applications that involve the analysis of poisonous compounds or metabolites from biological matrices such as fats and tissues, while GC-GC has been employed for complex samples, such as arson propellants and for samples in which special selectivity, such as chiral recognition, is required. Other techniques include on-line sample preparation methods, such as supercritical fluid extraction (SFE)-GC and LC-GC-GC. In many of these applications, the chromatographic method is coupled to mass spectrometry or another spectrometiic detector for final confirmation of the analyte identity, as required by many courts of law. [Pg.407]

Brain et al. [137] reported a tandem mass spectrometry (MS-MS) procedure by which a direct measurement from an n-pentane extract of a surfactant is possible. This procedure is excellent from the standpoint of sensitivity and simplicity of sample preparation but is not commonly applied because of the need of an MS-MS instrument. [Pg.448]

State-of-the-art TOF-SIMS instruments feature surface sensitivities well below one ppm of a mono layer, mass resolutions well above 10,000, mass accuracies in the ppm range, and lateral and depth resolutions below 100 nm and 1 nm, respectively. They can be applied to a wide variety of materials, all kinds of sample geometries, and to both conductors and insulators without requiring any sample preparation or pretreatment. TOF-SIMS combines high lateral and depth resolution with the extreme sensitivity and variety of information supplied by mass spectrometry (all elements, isotopes, molecules). This combination makes TOF-SIMS a unique technique for surface and thin film analysis, supplying information which is inaccessible by any other surface analytical technique, for example EDX, AES, or XPS. [Pg.33]

Several methods are available for the analysis of trichloroethylene in biological media. The method of choice depends on the nature of the sample matrix cost of analysis required precision, accuracy, and detection limit and turnaround time of the method. The main analytical method used to analyze for the presence of trichloroethylene and its metabolites, trichloroethanol and TCA, in biological samples is separation by gas chromatography (GC) combined with detection by mass spectrometry (MS) or electron capture detection (ECD). Trichloroethylene and/or its metabolites have been detected in exhaled air, blood, urine, breast milk, and tissues. Details on sample preparation, analytical method, and sensitivity and accuracy of selected methods are provided in Table 6-1. [Pg.229]

Although sophisticated methods may constitute the core methods for certification it is useful to include good, well executed routine methods. In order to further minimize systematic error, a conscious purposeful attempt should be made to get methods and procedures with wide-ranging and different sample preparation steps, including no decomposition as in instrumental neutron activation analysis and particle induced X-ray emission spectrometry. [Pg.56]

Frankenberger, Jr., and Muhammad Arshad Handbook of Weed Management Systems, edited by Albert E. Smith Soil Sampling, Preparation, and Analysis, Kim H. Tan Soil Erosion, Conservation, and Rehabilitation, edited by Menachem Agassi Plant Roots The Hidden Half, Second Edition, Revised and Expanded, edited by Yoav Waisel, Amram Eshel, and Uzi Kafkafi Photoassimilate Distribution in Plants and Crops Source-Sink Relationships, edited by Eli Zamski and Arthur A. Schaffer Mass Spectrometry of Soils, edited by Thomas W. Boutton and Shinichi Yamasaki... [Pg.430]

All previous discussion has focused on sample preparation, i.e., removal of the targeted analyte(s) from the sample matrix, isolation of the analyte(s) from other co-extracted, undesirable sample components, and transfer of the analytes into a solvent suitable for final analysis. Over the years, numerous types of analytical instruments have been employed for this final analysis step as noted in the preceding text and Tables 3 and 4. Overall, GC and LC are the most often used analytical techniques, and modern GC and LC instrumentation coupled with mass spectrometry (MS) and tandem mass spectrometry (MS/MS) detection systems are currently the analytical techniques of choice. Methods relying on spectrophotometric detection and thin-layer chromatography (TLC) are now rarely employed, except perhaps for qualitative purposes. [Pg.439]

Specifically for triazines in water, multi-residue methods incorporating SPE and LC/MS/MS will soon be available that are capable of measuring numerous parent compounds and all their relevant degradates (including the hydroxytriazines) in one analysis. Continued increases in liquid chromatography/atmospheric pressure ionization tandem mass spectrometry (LC/API-MS/MS) sensitivity will lead to methods requiring no aqueous sample preparation at all, and portions of water samples will be injected directly into the LC column. The use of SPE and GC or LC coupled with MS and MS/MS systems will also be applied routinely to the analysis of more complex sample matrices such as soil and crop and animal tissues. However, the analyte(s) must first be removed from the sample matrix, and additional research is needed to develop more efficient extraction procedures. Increased selectivity during extraction also simplifies the sample purification requirements prior to injection. Certainly, miniaturization of all aspects of the analysis (sample extraction, purification, and instrumentation) will continue, and some of this may involve SEE, subcritical and microwave extraction, sonication, others or even combinations of these techniques for the initial isolation of the analyte(s) from the bulk of the sample matrix. [Pg.445]

The need to understand the fate of pesticides in the environment has necessitated the development of analytical methods for the determination of residues in environmental media. Adoption of methods utilizing instrumentation such as gas chro-matography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS), liquid chromatography/tandem mass spectrometry (LC/MS/MS), or enzyme-linked immunosorbent assay (ELISA) has allowed the detection of minute amounts of pesticides and their degradation products in environmental samples. Sample preparation techniques such as solid-phase extraction (SPE), accelerated solvent extraction (ASE), or solid-phase microextraction (SPME) have also been important in the development of more reliable and sensitive analytical methods. [Pg.605]

The development of a robust analytical method is a complex issue. The residue analyst has available a vast array of techniques to assist in this task, but there are a number of basic rules that should be followed to produce a reliable method. The intention of this article is to provide the analyst with ideas from which a method can be constructed by considering each major component of the analytical method (sample preparation, extraction, sample cleanup, and the determinative step), and to suggest modern techniques that can be used to develop an effective and efficient overall approach. The latter portion emphasizes mass spectrometry (MS) since the current trend for pesticide residue methods is leading to MS becoming the method of choice for simultaneous quantitation and confirmation. This article also serves to update previous publications on similar topics by the authors. ... [Pg.753]

In addition to instrumental improvements, various approaches have been used to improve the purity or geometry of sources of natural samples for gamma spectrometric measurement. For example, improvements in source preparation for " Th measurement in water and sediment samples by gamma spectrometry are discussed in Cochran and Masque (2003). It should be emphasized that one of the main advantages of gamma spectrometry is ease of use, since in many cases samples may be analyzed directly or with significantly reduced sample preparation compared to alpha, beta, or mass spectrometric techniques. [Pg.31]

Sample preparation for the common desorption/ionisation (DI) methods varies greatly. Films of solid inorganic or organic samples may be analysed with DI mass spectrometry, but sample preparation as a solution for LSIMS and FAB is far more common. The sample molecules are dissolved in a low-vapour-pressure liquid solvent - usually glycerol or nitrobenzyl alcohol. Other solvents have also been used for more specialised applications. Key requirements for the solvent matrix are sample solubility, low solvent volatility and muted acid - base or redox reactivity. In FAB and LSIMS, the special art of sample preparation in the selection of a solvent matrix, and then manipulation of the mass spectral data afterwards to minimise its contribution, still predominates. Incident particles in FAB and LSIMS are generated in filament ionisation sources or plasma discharge sources. [Pg.384]

This chapter deals mainly with (multi)hyphenated techniques comprising wet sample preparation steps (e.g. SFE, SPE) and/or separation techniques (GC, SFC, HPLC, SEC, TLC, CE). Other hyphenated techniques involve thermal-spectroscopic and gas or heat extraction methods (TG, TD, HS, Py, LD, etc.). Also, spectroscopic couplings (e.g. LIBS-LIF) are of interest. Hyphenation of UV spectroscopy and mass spectrometry forms the family of laser mass-spectrometric (LAMS) methods, such as REMPI-ToFMS and MALDI-ToFMS. In REMPI-ToFMS the connecting element between UV spectroscopy and mass spectrometry is laser-induced REMPI ionisation. An intermediate state of the molecule of interest is selectively excited by absorption of a laser photon (the wavelength of a tuneable laser is set in resonance with the transition). The excited molecules are subsequently ionised by absorption of an additional laser photon. Therefore the ionisation selectivity is introduced by the resonance absorption of the first photon, i.e. by UV spectroscopy. However, conventional UV spectra of polyatomic molecules exhibit relatively broad and continuous spectral features, allowing only a medium selectivity. Supersonic jet cooling of the sample molecules (to 5-50 K) reduces the line width of their... [Pg.428]

Apart from the aforementioned sample preparation techniques (SFE, SPE and SPME), other sample collection modes are coupled directly to spectroscopy (e.g. fast pyrolysis and fast thermolysis-FTIR) and spectrometry (e.g. LD-ITMS). [Pg.452]

SFE-GC-MS is particularly useful for (semi)volatile analysis of thermo-labile compounds, which degrade at the higher temperatures used for HS-GC-MS. Vreuls et al. [303] have reported in-vial liquid-liquid extraction with subsequent large-volume on-column injection into GC-MS for the determination of organics in water samples. Automated in-vial LLE-GC-MS requires no sample preparation steps such as filtration or solvent evaporation. On-line SPE-GC-MS has been reported [304], Smart et al. [305] used thermal extraction-gas chromatography-ion trap mass spectrometry (TE-GC-MS) for direct analysis of TLC spots. Scraped-off material was gradually heated, and the analytes were thermally extracted. This thermal desorption method is milder than laser desorption, and allows analysis without extensive decomposition. [Pg.470]

Applications Real applications of spark-source MS started on an empirical basis before fundamental insights were available. SSMS is now considered obsolete in many areas, but various unique applications for a variety of biological substances and metals are reported. Usually, each application requires specific sample preparation, sparking procedure and ion detection. SSMS is now used only in a few laboratories worldwide. Spark-source mass spectrometry is still attractive for certain applications (e.g. in the microelectronics industry). This is especially so when a multi-element survey analysis is required, for which the accuracy of the technique is sufficient (generally 15-30% with calibration or within an order of magnitude without). SSMS is considered to be a... [Pg.651]

Mass spectrometry combines exquisite sensitivity with a precision that often depends more on the uncertainties of sampling and sample preparation than on those of the method itself. Mass spectrometry is a supreme identification and recognition method in polymer/additive analysis through highly accurate masses and fragmentation patterns quantitation is its weakness. Direct mass spectrometry of complex polymeric matrices is feasible, yet not often pursued. Solid probe ToF-MS (DI-HRMS) is a breakthrough. Where used routinely, mass spectrometrists are usually still in charge. At the same time, however, costs need to be watched. [Pg.734]

If we consider only a few of the general requirements for the ideal polymer/additive analysis techniques (e.g. no matrix interferences, quantitative), then it is obvious that the choice is much restricted. Elements of the ideal method might include LD and MS, with reference to CRMs. Laser desorption and REMPI-MS are moving closest to direct selective sampling tandem mass spectrometry is supreme in identification. Direct-probe MS may yield accurate masses and concentrations of the components contained in the polymeric material. Selective sample preparation, efficient separation, selective detection, mass spectrometry and chemometric deconvolution techniques are complementary rather than competitive techniques. For elemental analysis, LA-ICP-ToFMS scores high. [Pg.744]


See other pages where Sample preparation spectrometry is mentioned: [Pg.12]    [Pg.49]    [Pg.198]    [Pg.198]    [Pg.323]    [Pg.407]    [Pg.152]    [Pg.252]    [Pg.63]    [Pg.112]    [Pg.724]    [Pg.818]    [Pg.904]    [Pg.25]    [Pg.31]    [Pg.39]    [Pg.50]    [Pg.51]    [Pg.570]    [Pg.207]    [Pg.449]    [Pg.451]    [Pg.614]    [Pg.660]    [Pg.674]    [Pg.742]    [Pg.28]   
See also in sourсe #XX -- [ Pg.3 , Pg.192 ]




SEARCH



Accelerator mass spectrometry sample preparation

Atomic absorption spectrometry sample preparation

Atomic spectrometry sample preparation

Electrospray ionization mass spectrometry sample preparation

Glow discharge mass spectrometry sample preparation

Imaging mass spectrometry sample preparation

Inductively coupled plasma mass spectrometry sample preparation

Isotope ratio mass spectrometry sample preparation

Laser desorption/ionization mass spectrometry sample preparation

Liquid chromatography/mass spectrometry sample preparation

Mass spectrometry sample preparation

Sample Preparation for Atomic Spectrometry

Sample preparation Raman spectrometry

Sample spectrometry

Spark source mass spectrometry sample preparation

Spectroscopy/spectrometry coupled sample preparation

Tandem mass spectrometry Sample preparation