Liquid sample

Liquid samples may contain particles of solid material that need to be removed by filtration or centrifugation. The filter material mnst be chosen so that it does not adsorb analytes or contaminate the liquid. Some samples that are mostly liquid contain suspended solid material orange juice and liqnid antacids are examples. In these types of samples, the liqnid and its associated solids may need to be sampled for analysis withont removing the solids. It may be difficult to obtain a representative sample from these snspensions a standard sampling procednre is needed to ensnre that resnlts can be compared from one day to the next. Liquid samples may consist of more than one layer because they contain two or more immiscible liquids. Examples include samples of oil and water from an oil spill at sea, oil and vinegar salad dressing, or cream at the top of a bottle of milk. The layers may need to be emulsified to provide a representative sample, but it may be more useful to sample each layer separately. [Pg.17]

Sampling of hot molten materials snch as metals, alloys, and glasses is a form of liqnid sampling, but one requiring very specialized eqnipment and techniques. [Pg.17]

From the point of view of biological relevance ideally EPR spectra should be taken from aqueous solution samples at physiological temperatures. Not-so-ideal reality brings along two major practical problems paramagnetic relaxation and dielectric absorption. [Pg.50]

Sample cdls indude Lindemann/capillary tubes (normally 1 mm in diameter) and aluminum holders. In the latter, thin aluminum windows sandwich the sample in a cylindrical aluminum sample holder. The diffraction from the aluminum in this case is observed and may be used as a calibration standard. For low-temperature materials, the aluminum vyindow can be replaced by the polymer Kapton. Beryllium may also be used [17]. Typically, sample volumes of between 50 and 100 fiL are required. [Pg.184]

Binary mixtures which melt close to room temperature have also been investigated, namely AlQs-N-butjdpyridinium chloride mixtures. Takahashi et al. [20] have also shown that for the 1 1 composition, [AIQ4] predominates vyith a tetrahedral environment. At a ratio of 2 1, [Al2Q7] becomes the main species. At high temperature, that is above 150 °C, some decomposition to [AIQ4] and AI2Q6 vras observed. [Pg.185]

High energy X-ray diffraction has been used to examine the liquid structure of binary ionic liquids of 1,3-dialkyl imidazolium fluoride with HF [21]. As found for dimethyl imidazolium salts studied by neutron dif action (Section 4.1.5.2), the X-ray data showed that in these materials the solid state and liquid stmctures are closely related. The structures of molten [EMIM]F HF and [EMIM]F 2.3HF were found to be similar and showed the presence of [HF2] in the liquid, in agreement with the crystalline phase stractme. Shodai et al. also studied the structure of liquid [(CH3)4N]F wHF n = 3-5). A range of anion structures were found in the liquid, [(HF) Fj (x = 1-3) however, stmctures vyith higher ratios of HF to F (x = 4 or 5) were not found in the melt although similar compositions have been reported in the solid state [22]. [Pg.185]

Metal-Containing Systems Many of the systems studied are based on the [MQ4p anion. Neve et al. have studied extensively the formation of liquid crystalline phases on N-alkylpyridinium salts vyith alkyl chain lengths of re = 12-18 vyith tetrahalomet-allate anions based upon Pd(II) [27], Cu(II) [28], Co(II), Ni(ll), Zn(II) and Cd(II) [Pg.185]

Similar lamellar structures are formed for l-alkyl-3-methyltmidazolium cations with [PdQ4] when n 12. As with the pyridinium systems, mesomorphic liquid crystal stmctures are formed based on the smectic A structure [30]. [Pg.186]


Now using a hydrocarbon component, say ethane, as an example, let us consider the other parameter, volume, using a plot of pressure versus specific volume (i.e. volume per unit mass of the component, the inverse of the density). The process to be described could be performed physically by placing the liquid sample into a closed cell (PVT cell), and then reducing the pressure of the sample by withdrawing the piston of the cell and increasing the volume contained by the sample. [Pg.98]

It is especially useflil for liquid samples in flat cells, which may extend through tlie entire height of the cavity. In the cylindrical cavity a TEq mode is frequently used because of its fairly high g-factor and the very strong along the sample axis. [Pg.1560]

The vibration frequencies of C-H bond are noticeably higher for gaseous thiazole than for its dilute solutions in carbon tetrachloride or tor liquid samples (Table 1-27). The molar extinction coefficient and especially the integrated intensity of the same peaks decrease dramatically with dilution (203). Inversely, the y(C(2jH) and y(C(5(H) frequencies are lower for gaseous thiazole than for its solutions, and still lower than for liquid samples (cf. Table 1-27). [Pg.61]

Although the terms solute and solution are often associated with liquid samples, they can be extended to gas-phase and solid-phase samples as well. The actual units for reporting concentration depend on how the amounts of solute and solution are measured. Table 2.4 lists the most common units of concentration. [Pg.15]

Typical examples of liquid samples include those drawn from containers of commercial solvents beverages, such as milk or fruit juice natural waters, including from lakes, streams, seawater, and rain bodily fluids, such as blood and urine and, suspensions, such as those found in many oral medications. [Pg.193]

Sample Preservation Once removed from its target population, a liquid sample s chemical composition may change as a result of chemical, biological, or physical processes. Following its collection, samples are preserved by controlling the solu-... [Pg.194]

Solid-Phase Extractions In a solid-phase extraction the sample is passed through a cartridge containing solid particulates that serve as the adsorbent material. For liquid samples the solid adsorbent is isolated in either a disk cartridge or a column (Figure 7.17). The choice of adsorbent is determined by the properties of the species being retained and the matrix in which it is found. Representative solid adsorbents... [Pg.212]

Selected Adsorbents for Solid-Phase Extraction of Liquid Samples... [Pg.213]

A technique for separating volatile analytes from liquid samples in which the analytes are subsequently trapped on a solid adsorbent. [Pg.214]

Liquid samples are analyzed in one of two ways. For nonvolatile liquids a suitable sample can be prepared by placing a drop of the liquid between two NaCl plates, forming a thin film that typically is less than 0.01 mm thick. Volatile liquids must be placed in a sealed cell to prevent their evaporation. [Pg.393]

Porro, T. J. Pattacini, S. C. Sample Handling for Mid-Infrared Spectroscopy, Part 1 Solid and Liquid Sampling, Spectroscopy 1993, 8(7), 40-47. [Pg.458]

The liquid sample flows into the nozzle and coats the inside walls. The sample stream arrives at the orifice (the nozzle outlet is about 0.01 cm diameter), where it meets the argon stream and is nebulized. [Pg.144]

The aim of breaking up a thin film of liquid into an aerosol by a cross flow of gas has been developed with frits, which are essentially a means of supporting a film of liquid on a porous surface. As the liquid flows onto one surface of the frit (frequently made from glass), argon gas is forced through from the undersurface (Figure 19.16). Where the gas meets the liquid film, the latter is dispersed into an aerosol and is carried as usual toward the plasma flame. There have been several designs of frit nebulizers, but all work in a similar fashion. Mean droplet diameters are approximately 100 nm, and over 90% of the liquid sample can be transported to the flame. [Pg.146]

This arrangement provides a thin film of liquid sample solution flowing down to a narrow orifice (0.007-cm diameter) through which argon flows at high linear velocity (volume flow is about 0.5-1 1/min). A fine aerosol is produced. This particular nebulizer is efficient for solutions having a high concentration of analyte constituents. [Pg.147]

A liquid sample must be vaporized to a gas or, more likely, to a vapor consisting of an aerosol of gas, small droplets, and even small particles of solid matter. To be examined, the aerosol is mixed with argon gas to make up the needed flow of gas into the plasma and is then swept into the flame. [Pg.397]

Some elements (S, Se, Te, P, As, Sb, Bi, Ge, Sn, Pb) in liquid samples arc conveniently converted into their volatile hydrides before being passed into the plasma, as discussed in Part A (Chapter 15). For some samples, any volatile solvent is first evaporated in a sample holder, which is then heated strongly to vaporize the resulting solid residue, as discussed in Part C (Chapter 17). [Pg.397]

Desorption ionization (DI). General term to encompass the various procedures (e.g., secondary ion mass spectrometry, fast-atom bombardment, californium fission fragment desorption, thermal desorption) in which ions are generated directly from a solid or liquid sample by energy input. Experimental conditions must be clearly stated. [Pg.438]

Figure 8.28 shows how the X-rays fall on the solid or liquid sample which then emits X-ray fluorescence in the region 0.2-20 A. The fluorescence is dispersed by a flat crystal, often of lithium fluoride, which acts as a diffraction grating (rather like the quartz crystal in the X-ray monochromator in Figure 8.3). The fluorescence may be detected by a scintillation counter, a semiconductor detector or a gas flow proportional detector in which the X-rays ionize a gas such as argon and the resulting ions are counted. Figure 8.28 shows how the X-rays fall on the solid or liquid sample which then emits X-ray fluorescence in the region 0.2-20 A. The fluorescence is dispersed by a flat crystal, often of lithium fluoride, which acts as a diffraction grating (rather like the quartz crystal in the X-ray monochromator in Figure 8.3). The fluorescence may be detected by a scintillation counter, a semiconductor detector or a gas flow proportional detector in which the X-rays ionize a gas such as argon and the resulting ions are counted.
Liquid sampling from pressurized lines, using ungrounded or nonconductive containers... [Pg.2334]

Field Measurement Conditions Those gathering samples must be aware of the temperature, pressure, flamm ihty, and toxic characteristics of the samples for which they will be responsible. This is particularly important when samples are taken from unfamihar locations. Sample ports will have to be blown down to obtain representative samples. Liquid samples will have to be vented. Temperatures above... [Pg.2557]

The role of the nebulizer in ICPMS is to transform the liquid sample into an aerosol. This is carried into the plasma by an ai on flow after passing through a... [Pg.627]

Approximately 70 different elements are routinely determined using ICP-OES. Detection limits are typically in the sub-part-per-billion (sub-ppb) to 0.1 part-per-million (ppm) range. ICP-OES is most commonly used for bulk analysis of liquid samples or solids dissolved in liquids. Special sample introduction techniques, such as spark discharge or laser ablation, allow the analysis of surfaces or thin films. Each element emits a characteristic spectrum in the ultraviolet and visible region. The light intensity at one of the characteristic wavelengths is proportional to the concentration of that element in the sample. [Pg.633]

W. E. Petit and G. Horlick. Spect. Acta. 41B, 699, 1986. Describes an automated system for direct sample-insertion introduction of 10-pL liquid samples or small amounts (10 mg) of powder samples. [Pg.643]

The retentivity relative to solid particles (e.g., spherical particles of polystyrene of definite size) is found from experiments determining the amount of these particles in the suspension to be filtered before and after the filter media. The retentivity K is determined as follows where g, g" =amounts of solid particles in liquid sample before and after the medium, respectively. [Pg.150]

Supercritical fluid extraction (SFE) and Solid Phase Extraction (SPE) are excellent alternatives to traditional extraction methods, with both being used independently for clean-up and/or analyte concentration prior to chromatographic analysis. While SFE has been demonstrated to be an excellent method for extracting organic compounds from solid matrices such as soil and food (36, 37), SPE has been mainly used for diluted liquid samples such as water, biological fluids and samples obtained after-liquid-liquid extraction on solid matrices (38, 39). The coupling of these two techniques (SPE-SFE) turns out to be an interesting method for the quantitative transfer... [Pg.139]

A useful device to have installed in a stirred autoclave is a liquid sampling tube by which liquid samples are withdrawn under pressure through a filter attached to the lower end of the tube. This device is especially useful for analysis of reaction progress and supplements information obtained from pressure-drop determinations. It is much easier to improve a less than satisfactory yield, if it can be determined what is going wrong and when. For academically orientated persons, a study of the rise and decline of various reaction products, as a function of reaction parameters and catalyst, can be a fertile source of useful publications. [Pg.20]

The simplest method to measure gas solubilities is what we will call the stoichiometric technique. It can be done either at constant pressure or with a constant volume of gas. For the constant pressure technique, a given mass of IL is brought into contact with the gas at a fixed pressure. The liquid is stirred vigorously to enhance mass transfer and to allow approach to equilibrium. The total volume of gas delivered to the system (minus the vapor space) is used to determine the solubility. If the experiments are performed at pressures sufficiently high that the ideal gas law does not apply, then accurate equations of state can be employed to convert the volume of gas into moles. For the constant volume technique, a loiown volume of gas is brought into contact with the stirred ionic liquid sample. Once equilibrium is reached, the pressure is noted, and the solubility is determined as before. The effect of temperature (and thus enthalpies and entropies) can be determined by repetition of the experiment at multiple temperatures. [Pg.84]

Figure 4.1-1 Liquid sample cells made from (a) TiZr alloy and (b) vanadium. Figure 4.1-1 Liquid sample cells made from (a) TiZr alloy and (b) vanadium.

See other pages where Liquid sample is mentioned: [Pg.3030]    [Pg.434]    [Pg.26]    [Pg.214]    [Pg.263]    [Pg.263]    [Pg.418]    [Pg.578]    [Pg.777]    [Pg.106]    [Pg.110]    [Pg.220]    [Pg.214]    [Pg.252]    [Pg.443]    [Pg.29]    [Pg.157]    [Pg.622]    [Pg.634]    [Pg.638]    [Pg.309]    [Pg.129]    [Pg.130]   
See also in sourсe #XX -- [ Pg.39 , Pg.357 ]

See also in sourсe #XX -- [ Pg.19 ]

See also in sourсe #XX -- [ Pg.29 ]

See also in sourсe #XX -- [ Pg.18 , Pg.19 ]




SEARCH



Applications of Liquid Microseparation Devices for Process Stream Sampling and Coupling to Microreactors

Aqueous liquid samples

Atomic absorption spectrometry liquid samples

Cells for liquid samples

Chemical sample, liquid

Continuous sample inlet, liquid chromatography

Drying samples liquid

Drying samples, liquid solid

HPLC (high performance liquid sample introduction

HPLC (high performance liquid sample loop

HPLC (high performance liquid sample preparation

Headspace sampling techniques liquid samples

High performance liquid blood samples

High performance liquid chromatography sample injection

High performance liquid chromatography sample preparation

High-performance liquid chromatography degradation samples

High-performance liquid chromatography sample capacity

High-performance liquid chromatography sample contamination

High-performance liquid chromatography sample injector

High-performance liquid chromatography samples

High-performance liquid sample preparation

High-pressure liquid chromatography Sample preparation

Infrared analysis liquid samples

Infrared spectroscopy liquid samples

Karl Fischer Titrator (for Liquid Samples)

Liquid Chromatography Sample preparation

Liquid Samples and Solutions

Liquid chromatography parallel sample analysis

Liquid chromatography sample recovery from columns

Liquid chromatography sample size

Liquid chromatography sample volume

Liquid chromatography sampling methods

Liquid chromatography with automated sampling devices

Liquid chromatography-mass samples

Liquid chromatography/mass sample preparation method

Liquid chromatography/mass spectrometry biomedical samples

Liquid chromatography/mass spectrometry sample preparation

Liquid continuous sampling

Liquid cylindrical sample cells

Liquid fully automated sample treatment

Liquid microjunction surface sampling probe

Liquid parallel-plate sample cells

Liquid sample inlet systems

Liquid sample introduction direct

Liquid samples exercises

Liquid samples extraction procedure

Liquid samples plasma emission spectroscopy

Liquid samples sample-handling techniques

Liquid samples system

Liquid samples, automatic analysis

Liquid samples, preliminary tests

Liquid sampling

Liquid sampling in batch analysers

Liquid sampling in continuous analysers

Liquid sampling valve

Liquid thermoset samples

Liquid-solid chromatography sample cleanup

Liquids analysis sample transport systems

Liquids, automatic sampling

Neutron Cells for Liquid Samples

Organic liquid samples

Parallel Liquid Handling of Low-Volume Samples

Preparation of Liquid Samples

Problem samples liquids, slurries and solids

Rapid large-volume liquid sampling

Reversed-phase liquid chromatography aqueous samples

Sample Cleanup Using Liquid Chromatography

Sample Handling Analysis of Solids, Liquids, and Gases

Sample Handling Liquids

Sample handling liquid samples

Sample introduction liquid

Sample introduction liquid chromatography

Sample liquid chromatography

Sample liquid samples

Sample online liquid chromatography clean

Sample preparation automated, high-performance liquid

Sample preparation liquid extraction from solid

Sample preparation liquid-solid

Sample preparation liquids

Sample preparation methods Liquid samples

Sample preparation solid-liquid extraction

Sample preparation supported liquid extraction

Sample-handling techniques liquids

Samples liquid crystals

Sampling of liquids

Solid-liquid mixing measurement, sampling

Solid-liquid samples

Solid-phase microextraction from liquid samples

Solid/liquid separation samples

Solution Prepared and Placed in a Liquid Sampling Cell

Static headspace extraction liquid sample matrices

The Extraction of Liquid Samples

Ultrasonic Analysis of Liquid Samples

Ultrasound-assisted liquid sample preparation involving chemical reactions

Ultrasound-assisted liquid sample preparation without chemical reaction

© 2024 chempedia.info