Infrared spectroscopy liquid samples

Infrared spectra may be obtained for gases, liquids, orsolids. For transmittance infrared spectroscopy, the sampling techniques may involve a solution, a film, amull, or a pellet, depending on the type of sample. Reflectance spectroscopy differs from transmittance spectroscopy in that infrared radiation reflected from the surface of a material is studied. With a proper sampling accessory (obtainable from commercial sources), the materials analyzed by reflectance techniques normally require little or no sample preparation. The method is non-destructive, non-invasive, and very useful for analyzing materials that are too thick or have too much absorbance to be analyzed by transmittance spectroscopy. [Pg.3412]

See alsa. Adhesives and Sealants. Food and Nutritional Analysis Oils and Fats. Infrared Spectroscopy Overview Sample Presentation Industrial Applications. Liquid Chromatography Food Applications. Plastics. Sensory Evaluation. [Pg.1603]

First, the student should become aware of the fact that more concentrated samples are required for far-infrared spectroscopy. Liquid cells may have longer pathlengths, or a more concentrated solution must be determined in order to obtain reasonable absorption bands. [Pg.123]

Infrared spectroscopy is routinely used for the analysis of samples in the gas, liquid, and solid states. Sample cells are made from materials, such as NaCl and KBr, that are transparent to infrared radiation. Gases are analyzed using a cell with a pathlength of approximately 10 cm. Longer pathlengths are obtained by using mirrors to pass the beam of radiation through the sample several times. [Pg.393]

Porro, T. J. Pattacini, S. C. Sample Handling for Mid-Infrared Spectroscopy, Part 1 Solid and Liquid Sampling, Spectroscopy 1993, 8(7), 40-47. [Pg.458]

To measure gas and water vapor permeability, a film sample is mounted between two chambers of a permeability cell. One chamber holds the gas or vapor to be used as the permeant. The permeant then diffuses through the film into a second chamber, where a detection method such as infrared spectroscopy, a manometric, gravimetric, or coulometric method isotopic counting or gas-liquid chromatography provides a quantitative measurement (2). Die measurement depends on the specific permeant and the sensitivity required. [Pg.241]

Reaction of K3Co(CN) with PMMA. A 1.0 g sample of PMMA and 1.0g of the cobalt compound were combined in a standard vessel and pyrolyzed for 2 hrs at 375°C. The tube was removed from the oven and the contents of the tube were observed to be solid (PMMA is liquid at this temperature). The tube was reattached to the vacuum line via the break-seal and opened. Gases were determined by pressure-volume-temperature measurements on the vacuum line and identified by infrared spectroscopy. Recovered were 0.22g of methyl methacrylate and 0.11 g of CO and C02. The tube was then removed from the vacuum line and acetone was added. Filtration gave two fractions, 1.27g of acetone insoluble material and 0.30g of acetone soluble (some soluble material is always lost in the recovery process). The acetone insoluble fraction was then slurried with water, 0.11 g of material was insoluble in water. Infrared analysis of this insoluble material show both C-H and C-0 vibrations and are classified as char based upon infrared spectroscopy. Reactions were also performed at lower temperature, even at 260°C some char is evident in the insoluble fraction. [Pg.180]

Of the analytical techniques available for process analytical measmements, IR is one of the most versatile, where all physical forms of a sample may be considered - gases, liquids, solids and even mixed phase materials. A wide range of sample interfaces (sampling accessories) have been developed for infrared spectroscopy over the past 20 to 30 years and many of these can be adapted for either near-lme/at-lme production control or on-line process monitoring applications. For continuous on-line measurements applications may be limited to liquids and gases. However, for applications that have human interaction, such as near-line measurements, then all material types can be considered. For continuous measurements sample condition, as it exists within the process, may be an issue and factors such as temperature, pressure, chemical interfer-ants (such as solvents), and particulate matter may need to be addressed. In off-line applications this may be addressed by the way that the sample is handled, but for continuous on-line process applications this has to be accommodated by a sampling system. [Pg.157]

T.J. Porro, S.C. Pattacini, Sample handling for mid-infrared spectroscopy. Part I solid and liquid sampling. Spectroscopy, 8(7), 40 7 (1993). [Pg.194]

Infrared spectroscopy is a relatively simple technique, nondestructive, and versatile enough to analyze solids, liquids, and gases with a minimum of sample preparation. Polymers can be mixed with potassium bromide and then pressed into pellets. Films can be prepared from melt or cast from solution and can be studied easily. In bulk samples or powders, or if a concentration profile is needed, the reflectance technique is probably more suitable than transmission. [Pg.104]

Modern infrared (IR) spectroscopy is a versatile tool applied to the qualitative and quantitative determination of molecular species of all types. Its applications fall into three categories based on the spectral regions considered. Mid-IR (MIR) is by far the most widely used, with absorption, reflection, and emission spectra being employed for both qualitative and quantitative analysis. The NIR region is particularly used for routine quantitative determinations in complex samples, which is of interest in agriculture, food and feed, and, more recently, pharmaceutical industries. Determinations are usually based on diffuse reflectance measurements of untreated solid or liquid samples or, in some cases, on transmittance studies. Far-IR (FIR) is used primarily for absorption measurements of inorganic and metal-organic samples. [Pg.365]

Infrared spectroscopy. IR spectra were recorded on a Nicolet 5DX FT-IR spectrometer. A thin coating of the condensed silanes was applied on KBr pellets made from a very high purity KBr powder (J. T. Baker Chemical Co.). The spectra of these pellets were recorded using the transmission method. Liquid silanes were analyzed using the internal reflection attachment (IRA). The number of scans was chosen to be 20 for both background and samples. [Pg.478]

Infrared spectroscopy is used by the pharmaceutical industry to identify and discriminate between drugs that are similar in structure, for example penicillin-type drugs. Used both with organic and inorganic molecules, this method assumes that each compound has a unique infrared spectrum. Samples can be solid, liquid or gas and are usually tiny However, Ne, He, 02, N2 or H2 cannot be used. [Pg.27]

Multidimentional nonlinear infrared spectroscopy is used for identification of dynamic structures in liquids and conformational dynamics of molecules, peptides and, in principle, small proteins in solution (Asplund et al., 2000 and references herein). This spectroscopy incorporates the ability to control the responses of particular vibrational transitions depending on their couplings to one another. Two and three-pulse IR photon echo techniques were used to eliminate the inhomogeneous broadening in the IR spectrum. In the third-order IR echo methods, three phase-locked IR pulses with wave vectors kb k2, and k3 are focused on the sample at time intervals. The IR photon echo eventually emitted and the complex 2D IR spectrum is obtained with the use of Fourier transformation. The method was applied to the examination of vibrational properties of N-methyl acetamid and a dipeptide, acyl-proline-NH2.in D20. The 2D IR spectrum showed peaks at 1,610 and 1, 670 cm 1, the two frequencies ofthe acyl-proline dipeptide. Geometry and time-ordering of the incoming pulse sequence in fifth-order 2D spectroscopy is shown in Fig. 1.3. [Pg.5]

Near-infrared absorption is therefore essentially due to combination and overtone modes of higher energy fundamentals, such as C-H, N-H, and O-H stretches, which appear as lower overtones and lower order combination modes. Since the NIR absorption of polyatomic molecules thus mainly reflects vibrational contributions from very few functional groups, NIR spectroscopy is less suitable for detailed qualitative analysis than IR, which shows all (active) fundamentals and the overtones and combination modes of low-energy vibrations. On the other hand, since the vibrational intensities of near-infrared bands are considerably lower than those of corresponding infrared bands, optical layers of reasonable size (millimeters, centimeters) may be transmitted in the NIR, even in the case of liquid samples, compared to the layers of pm size which are detected in the infrared. This has important consequences for the direct quantitative study of chemical reactions, chemical equilibria, and phase equilibria via NIR spectroscopy. [Pg.519]


See other pages where Infrared spectroscopy liquid samples is mentioned: [Pg.123]    [Pg.43]    [Pg.416]    [Pg.314]    [Pg.419]    [Pg.496]    [Pg.77]    [Pg.181]    [Pg.841]    [Pg.55]    [Pg.188]    [Pg.379]    [Pg.62]    [Pg.65]    [Pg.369]    [Pg.295]    [Pg.98]    [Pg.52]    [Pg.273]    [Pg.144]    [Pg.228]    [Pg.39]    [Pg.297]    [Pg.25]    [Pg.36]    [Pg.4]    [Pg.482]    [Pg.43]    [Pg.251]    [Pg.533]    [Pg.57]    [Pg.193]    [Pg.203]    [Pg.253]   
See also in sourсe #XX -- [ Pg.864 , Pg.865 , Pg.866 , Pg.866 ]

See also in sourсe #XX -- [ Pg.244 ]