HPLC high performance liquid sample preparation

Scheme 5.1 A protocol for sample preparation prior to chiral analysis of the pollutants. Note that this is only a brief outline of the sample preparation procedure. MAE, microwave assisted extraction SE, Soxhlet extraction ASE, accelerated solvent extraction SFE, solid phase extraction CC, column chromatography HPLC, high performance liquid chromatography SFC, supercritical fluid chromatography GPC, gel permeation chromatography. Scheme 5.1 A protocol for sample preparation prior to chiral analysis of the pollutants. Note that this is only a brief outline of the sample preparation procedure. MAE, microwave assisted extraction SE, Soxhlet extraction ASE, accelerated solvent extraction SFE, solid phase extraction CC, column chromatography HPLC, high performance liquid chromatography SFC, supercritical fluid chromatography GPC, gel permeation chromatography.
As a method of research, has been used high-performance liquid chromatography in reversed - phase regime (RP HPLC). The advantage of the present method is the following the additional information about AIST and FAS composition (homologous distribution) simple preparation of samples (dilution of a CS sample of in a mobile phase). [Pg.133]

Sample preparation for analysis by hyphenated methods requires some additional planning when compared to nonhyphenated methods. All steps, extraction, concentration, and final solvent selection must take into consideration and be compatible with all the components of the hyphenated instrumentation. For gas chromatographic methods, all the components in the mixture must be in the gaseous state. For liquid chromatography (LC) or high-performance liquid chromatography (HPLC), the samples of the analytes of interest can be solids or liquids, neutral or charged molecules, or ions, but they must be in solution. If the follow-on analysis is by MS, then each of the analytes may require a different method of introduction into the MS. Metals and metal ions may be introduced by HPLC if they are in solution but commonly are introduced via AAS or inductively coupled plasma (ICP). Other analytes may be directly introduced from HPLC to MS [2],... [Pg.324]

Raman often is evaluated as an alternative to an existing high performance liquid chromatography (HPLC) method because of its potential to be noninvasive, fast, simple to perform, and solvent-free. Raman was compared to HPLC for the determination of ticlopidine-hydrochloride (TCL) [43], risperidone [44] in film-coated tablets, and medroxyprogesterone acetate (MPA) in 150-mg/mL suspensions (DepoProvera, Pfizer) [45] it was found to have numerous advantages and performance suitable to replace HPLC. In an off-line laboratory study, the relative standard deviation of the measurement of the composition of powder mixtures of two sulfonamides, sulfathiazole and sulfanilamide, was reduced from 10-20% to less than 4% by employing a reusable, easily prepared rotating sample cell [46]. [Pg.209]

In the separation of biomolecules, sample preparation almost always involves the use of one or more pretreatment techniques. With high-performance liquid chromatography (HPLC), no one sample preparation technique can be appHed to all biological samples. Several techiques may be used to prepare the sample for injection. For example, complex samples require some form of preffactionation before analysis, samples that are too dilute for detection require concentration before analysis, samples in an inappropriate or incompatible solvent require buffer exchange before analysis, and samples that contain particulates require filtration before injection into the analytical instrument. [Pg.118]

High-performance liquid chromatography (HPLC), followed by GC/MS, has been used to fractionate and then quantitate the aliphatic and aromatic hydrocarbons present in liquid fuel precursors in order to determine the fuel potential of the compounds. Kerosene had the advantage of not requiring any sample preparation. Other light fuel oils may require the use of methylene chloride as a solvent prior to HPLC analysis (Lamey et al. 1991). The sensitivity, precision, and recovery of this method were not reported. [Pg.156]

In bioanalysis, High-Performance Liquid Chromatography (HPLC) is the analytical technique most frequently used. Often, extended sample preparation is required to make a biological sample (the matrix) suitable for HPLC-analysis. The compound of interest, the analyte, has to be isolated from the matrix as selective and quantitative as possible. The quality of the sample preparation largely determines the quality of the total analysis procedure. In a survey Majors [2] showed that approximately 30% of an error generated during sample analysis was due to sample preparation, which indicates the need for error reduction and quality improvement in sample preparation. [Pg.266]

Figure 3.2 A scientist prepares a high-performance liquid chromatography (HPLC) machine to analyze a blood sample. The results of the test are visualized on the monitor to her right. Figure 3.2 A scientist prepares a high-performance liquid chromatography (HPLC) machine to analyze a blood sample. The results of the test are visualized on the monitor to her right.
The chemical properties of HVA, 5HIAA and 3-MD make them amenable to reverse-phase high-performance liquid chromatography (HPLC) with electrochemical detection. Furthermore, the composition of CSF means that little, if any, sample preparation is required prior to analysis. However, the susceptibility of these metabolites to oxidation means that careful sample collection and storage is required in order to minimise analyte degradation. [Pg.704]

Currently, high-performance liquid chromatography (HPLC) methods have been widely used in the analysis of tocopherols and tocotrienols in food and nutrition areas. Each form of tocopherol and tocotrienol can be separated and quantified individually using HPLC with either a UV or fluorescence detector. The interferences are largely reduced after separation by HPLC. Therefore, the sensitivity and specificity of HPLC methods are much higher than those obtained with the colorimetric, polarimetric, and GC methods. Also, sample preparation in the HPLC methods is simpler and more efficiently duplicated than in the older methods. Many HPLC methods for the quantification of tocopherols and tocotrienols in various foods and biological samples have been reported. Method number 992.03 of the AOAC International Official Methods of Analysis provides an HPLC method to determine vitamin E in milk-based infant formula. It could probably be said that HPLC methods have become dominant in the analysis of tocopherols and tocotrienols. Therefore, the analytical protocols for tocopherols and tocotrienols in this unit are focused on HPLC methods. Normal and reversed-phase HPLC methods are discussed in the separation and quantification of tocopherols and tocotrienols (see Basic Protocol). Sample... [Pg.479]


See other pages where HPLC high performance liquid sample preparation is mentioned: [Pg.14]    [Pg.578]    [Pg.252]    [Pg.697]    [Pg.724]    [Pg.904]    [Pg.231]    [Pg.27]    [Pg.322]    [Pg.606]    [Pg.73]    [Pg.120]    [Pg.301]    [Pg.415]    [Pg.423]    [Pg.137]    [Pg.121]    [Pg.19]    [Pg.18]    [Pg.414]    [Pg.61]    [Pg.51]    [Pg.337]    [Pg.183]    [Pg.405]    [Pg.87]    [Pg.99]    [Pg.251]    [Pg.175]    [Pg.173]    [Pg.211]    [Pg.28]    [Pg.393]    [Pg.394]    [Pg.623]    [Pg.404]    [Pg.562]    [Pg.771]    [Pg.1287]    [Pg.595]    [Pg.764]   
See also in sourсe #XX -- [ Pg.247 ]




SEARCH



HPLC, High performance

High-performance liquid preparative

High-performance liquid sample preparation

Liquid HPLC)

Liquid preparations

Liquid samples

Sample HPLC)

Sample preparation liquids

© 2024 chempedia.info