Time of flight mass

Figure Bl.7.17. (a) Schematic diagram of a single acceleration zone time-of-flight mass spectrometer, (b) Schematic diagram showing the time focusing of ions with different initial velocities (and hence initial kinetic energies) onto the detector by the use of a reflecting ion mirror, (c) Wiley-McLaren type two stage acceleration zone time-of-flight mass spectrometer. Figure Bl.7.17. (a) Schematic diagram of a single acceleration zone time-of-flight mass spectrometer, (b) Schematic diagram showing the time focusing of ions with different initial velocities (and hence initial kinetic energies) onto the detector by the use of a reflecting ion mirror, (c) Wiley-McLaren type two stage acceleration zone time-of-flight mass spectrometer.
Time-of-flight mass spectrometers have been used as detectors in a wider variety of experiments tlian any other mass spectrometer. This is especially true of spectroscopic applications, many of which are discussed in this encyclopedia. Unlike the other instruments described in this chapter, the TOP mass spectrometer is usually used for one purpose, to acquire the mass spectrum of a compound. They caimot generally be used for the kinds of ion-molecule chemistry discussed in this chapter, or structural characterization experiments such as collision-induced dissociation. Plowever, they are easily used as detectors for spectroscopic applications such as multi-photoionization (for the spectroscopy of molecular excited states) [38], zero kinetic energy electron spectroscopy [39] (ZEKE, for the precise measurement of ionization energies) and comcidence measurements (such as photoelectron-photoion coincidence spectroscopy [40] for the measurement of ion fragmentation breakdown diagrams). [Pg.1354]

Guilhaus M 1995 Principles and instrumentation in time-of-flight mass spectrometry physical and instrumental concepts J. Mass Spectrom. 30 1519-32... [Pg.1360]

Wiley W C and McLaren I H 1955 Time-of-flight mass spectrometer with improved resolution Rev. Sc/. Instrum. 26 1150-7... [Pg.1360]

Karataev V I, Mamyrin B A and Shmikk D V 1972 New method for focusing ion bunches in time-of-flight mass spectrometers Sov. Phys.-Tech. Phys. 16 1177... [Pg.2401]

Bergmann T, Martin T P and Schaber H 1989 High-resolution time-of-flight mass spectrometer Rev. Sol. Instrum. 60 792... [Pg.2401]

The "time of flight" mass spectrometer has been used to confirm that this highly radioactive halogen behaves chemically very much like other halogens, particularly iodine. Astatine is said to be more metallic than iodine, and, like iodine, it probably accumulates in the thyroid gland. Workers at the Brookhaven National Laboratory have recently used reactive scattering in crossed molecular beams to identify and measure elementary reactions involving astatine. [Pg.150]

Orthogonal TOP is the name commonly given to orthogonally accelerated time-of-flight mass spectrometry. It is sometimes referred to by the acronym oa-TOF, especially in official publications, but it is more usual for it to be referred to simply as orthogonal TOP this abbreviation is used here. [Pg.407]

Cotter, R.J., Time-of-Flight Mass Spectrometry, ACS Symposium Series, Vol. 549, American Chemical Society, Washington, DC, 1994. [Pg.450]

In Surface Analysis by Laser Ionization (SALI), a probe beam such as an ion beam, electron beam, or laser is directed onto a surfiice to remove a sample of material. An untuned, high-intensity laser beam passes parallel and close to but above the sur-fiice. The laser has sufficient intensity to induce a high degree of nonresonant, and hence nonselective, photoionization of the vaporized sample of material within the laser beam. The nonselectively ionized sample is then subjected to mass spectral analysis to determine the nature of the unknown species. SALI spectra accurately reflect the surface composition, and the use of time-of-flight mass spectrometers provides fast, efficient and extremely sensitive analysis. [Pg.42]

In Laser Ionization Mass Spectrometry (LIMS, also LAMMA, LAMMS, and LIMA), a vacuum-compatible solid sample is irradiated with short pulses ("10 ns) of ultraviolet laser light. The laser pulse vaporizes a microvolume of material, and a fraction of the vaporized species are ionized and accelerated into a time-of-flight mass spectrometer which measures the signal intensity of the mass-separated ions. The instrument acquires a complete mass spectrum, typically covering the range 0— 250 atomic mass units (amu), with each laser pulse. A survey analysis of the material is performed in this way. The relative intensities of the signals can be converted to concentrations with the use of appropriate standards, and quantitative or semi-quantitative analyses are possible with the use of such standards. [Pg.44]

Laser ionization mass spectrometry or laser microprobing (LIMS) is a microanalyt-ical technique used to rapidly characterize the elemental and, sometimes, molecular composition of materials. It is based on the ability of short high-power laser pulses (-10 ns) to produce ions from solids. The ions formed in these brief pulses are analyzed using a time-of-flight mass spectrometer. The quasi-simultaneous collection of all ion masses allows the survey analysis of unknown materials. The main applications of LIMS are in failure analysis, where chemical differences between a contaminated sample and a control need to be rapidly assessed. The ability to focus the laser beam to a diameter of approximately 1 mm permits the application of this technique to the characterization of small features, for example, in integrated circuits. The LIMS detection limits for many elements are close to 10 at/cm, which makes this technique considerably more sensitive than other survey microan-alytical techniques, such as Auger Electron Spectroscopy (AES) or Electron Probe Microanalysis (EPMA). Additionally, LIMS can be used to analyze insulating sam-... [Pg.586]

Sputter-Initiated Resonance Ionization Spectroscopy Surface Analysis by Resonant Ionization Spectroscopy Time-of-Flight Mass Spectrometer... [Pg.768]

SIMS using Time-of-Flight Mass Spectrometer Post Ionization SIMS... [Pg.768]

To minimize surface damage, static SIMS mass spectrometers should be as efficient as possible for detecting the total yield of secondary ions from a surface. Also, to be able to separate elemental from molecular species, and molecular species from each other, the mass resolution usually given as the mass m divided by the separable mass Am, should be very high. With this in mind, two types of mass spectrometer have been used - in early work mainly quadrupole mass filters and, more recently, time-of-flight mass spectrometers. [Pg.89]

Isotope shifts for most elements are small in comparison with the bandwidth of the pulsed lasers used in resonance ionization experiments, and thus all the isotopes of the analyte will be essentially resonant with the laser. In this case, isotopic analysis is achieved with a mass spectrometer. Time-of flight mass spectrometers are especially well-suited for isotopic analysis of ions produced by pulsed resonance ionization lasers, because all the ions are detected on each pulse. [Pg.135]

Molecular orbital calculations indicate that cyclo C-18 carbyne should be relatively stable and experimental evidence for cyclocarbynes has been found [25], Fig. 3B. Diederich et al [25] synthesised a precursor of cyclo C-18 and showed by laser flash heating and time-of flight mass spectrometry that a series of retro Diels-Alder reactions occurred leading to cyclo C-18 as the predominant fragmentation pattern. Diederich has also presented a fascinating review of possible cyclic all-carbon molecules and other carbon-rich nanometre-sized carbon networks that may be susceptible to synthesis using organic chemical techniques [26]. [Pg.8]

Fig. I. Experimental setup the clusters are emitted from the cluster condensation cell, passing as a particle beam through a differential pumping stage into the focus of a time-of-flight mass spectrometer, where they are ionized by a laser pulse. Fig. I. Experimental setup the clusters are emitted from the cluster condensation cell, passing as a particle beam through a differential pumping stage into the focus of a time-of-flight mass spectrometer, where they are ionized by a laser pulse.
After condensation, the clusters are transported by the He-flow through a nozzle and a differential pumping stage into a high vacuum chamber. For ionization of the clusters, we used excimer and dye laser pulses at various wavelengths. The ions were then mass analyzed by a time-of-flight mass spectrometer, having... [Pg.170]

J. A. Lippeit, B. Xin, N. Wu and M. L. Lee, East ultraliigh-pressure liquid chromatography on-column UV and time-of-flight mass spectrometric detection , 7. Microcolumn. Sep. 11 631 (1999). [Pg.14]

TOP (Section 12.4) Time-of flight mass spectrometry a sensitive method of mass detection accurate to about 3 ppm. [Pg.1252]

Electrospray ionization mass spectrometry (ESI-MS) is an analytical method for mass determination of ionized molecules. It is a commonly used method for soft ionization of peptides and proteins in quadmpole, ion-trap, or time-of-flight mass spectrometers. The ionization is performed by application of a high voltage to a stream of liquid emitted from a capillaty. The highly charged droplets are shrunk and the resulting peptide or protein ions are sampled and separated by the mass spectrometer. [Pg.458]

The molecular weights and molecular weight distributions (MWD) of phenolic oligomers have been evaluated using gel permeation chromatography (GPC),23,24 NMR spectroscopy,25 vapor pressure osmometry (VPO),26 intrinsic viscosity,27 and more recently matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS).28... [Pg.385]


See other pages where Time of flight mass is mentioned: [Pg.1351]    [Pg.2083]    [Pg.193]    [Pg.411]    [Pg.333]    [Pg.333]    [Pg.251]    [Pg.563]    [Pg.587]    [Pg.589]    [Pg.90]    [Pg.133]    [Pg.180]    [Pg.296]    [Pg.298]    [Pg.169]    [Pg.169]    [Pg.180]    [Pg.52]    [Pg.22]    [Pg.345]    [Pg.259]   


SEARCH



Additional Time-of-Flight Mass Spectrometry Experiments

Chemical ionization reaction time-of-flight mass

DTIMS Time-of-Flight Mass Spectrometry

Electrospray ionization time-of-flight mass

Electrospray ionization-time of flight-mass spectrometer

Electrospray-Time of Flight-Mass Spectrometry

Flight time

Fragmentation in the Time-of-Flight Mass Spectrometer

High-resolution time-of-flight mass

High-resolution time-of-flight mass spectrometry

ICP time-of-flight mass spectrometry

Imaging time of flight secondary Ion mass spectrometry

Inductively coupled plasma time-of-flight mass

Inductively coupled plasma time-of-flight mass spectrometry

Ion mobility-time-of-flight mass spectrometry

Linear time-of-flight mass spectrometer

Liquid chromatography-time-of-flight mass

Liquid chromatography-time-of-flight mass spectrometry

MALDI time-of-flight mass spectrometer

MALDI-TOF-MS (matrix-assisted laser desorption ionization time-of-flight mass

Mass Analysis in Time-of-Flight Analyser

Mass Spectrometry in Biological Chemistry Time-of-Flight (TOF) Instruments

Mass Spectrometry in Biological Chemistry Time-of-Flight (TOF) nstruments

Matrix Assisted Laser Desorption Ionization-Time of Flight-Mass Spectrometry (MALDI-TOF-MS)

Matrix-assisted laser desorption - time-of-flight mass spectroscopy

Matrix-assisted laser desorption ionisation-time of flight mass

Matrix-assisted laser desorption ionisation-time of flight mass spectrometry

Matrix-assisted laser desorption ionization time-of-flight mass

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry

Matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy

Photoionization time-of-flight mass

Proton transfer reaction time-of-flight mass spectrometry

Pulsed radiofrequency glow discharge time-of-flight mass

Quadrupole ion trap -time of flight mass spectrometer

Quadrupole time-of-flight hybrid mass spectrometers

Quadrupole time-of-flight mass spectrometer

Quadrupole-time of flight mass spectrometry

Quadrupole-time-of-flight mass

Quadrupole-time-of-flight mass analyser

Quadrupole/time-of-flight tandem mass spectrometry

Reflectron time of flight mass spectrometer

Reflectron time-of-flight mass

Reflectron time-of-flight mass spectrometry

Resonance-Enhanced Multiphoton Ionisation Time-of-Flight Mass Spectrometry

Tandem mass spectrometry with time-of-flight analyser

The Time-of-Flight Mass Analyser

The Time-of-Flight Mass Spectrometer

Time of flight mass analyse

Time of flight mass spectrometry (TOF

Time of flight secondary ion mass

Time of flight static secondary ion mass spectrometry

Time-of-Flight Mass Spectrometry

Time-of-Flight Secondary Ion Mass Spectrometry

Time-of-Flight Secondary Ion Mass Spectrometry TOF-SIMS)

Time-of-flight

Time-of-flight (TOF) mass spectromete

Time-of-flight Mass Spectrometers (ToF-MS)

Time-of-flight mass analyser (

Time-of-flight mass analysis

Time-of-flight mass analyzer

Time-of-flight mass spectra

Time-of-flight mass spectromete

Time-of-flight mass spectrometer

Time-of-flight mass spectrometer TOFMS)

Time-of-flight mass spectrometer, TOF

Time-of-flight mass spectrometr

Time-of-flight mass spectrometric

Time-of-flight mass spectrometry TOF-MS)

Time-of-flight mass spectrometry ToFMS)

Time-of-flight mass spectrometry, MALDI

Time-of-flight secondary ion mass spectrometer

Time-of-flight secondary ion mass spectrometry ToFSIMS)

Time-of-flight secondary ion mass spectroscopy

Time-of-flight secondary ion mass spectroscopy ToF SIMS)

Time-of-flight tandem mass spectrometers

Time-of-flight tandem mass spectrometry

© 2024 chempedia.info