Probe beam

Then, the weld depths penetration are controlled in a pulse-echo configuration because the weld bead (of width 2 mm) disturbs the detection when the pump and the probe beams are shifted of 2.2 mm. The results are presented in figure 8 (identical experimental parameters as in figure 7). The slow propagation velocities for gold-nickel alloy involve that the thermal component does not overlap the ultrasonic components, in particular for the echo due to the interaction with a lack of weld penetration. The acoustic response (V shape) is still well observed both for the slot of height 1.7 mm and for a weld depth penetration of 0.8 mm (lack of weld penetration of 1.7 mm), even with the weld bead. This is hopeful with regard to the difficulties encountered by conventional ultrasound in the case of the weld depths penetration. [Pg.698]

If a surface, typically a metal surface, is irradiated with a probe beam of photons, electrons, or ions (usually positive ions), one generally finds that photons, electrons, and ions are produced in various combinations. A particular method consists of using a particular type of probe beam and detecting a particular type of produced species. The method becomes a spectroscopic one if the intensity or efficiency of the phenomenon is studied as a function of the energy of the produced species at constant probe beam energy, or vice versa. Quite a few combinations are possible, as is evident from the listing in Table VIII-1, and only a few are considered here. [Pg.306]

As a final example, similar spectroscopy was carried out for CO2 physisorbed on MgO(lOO) [99]. Temperatures were around 80 K and equilibrium pressures, as low as 10 atm (at higher temperatures, CO2 chemsorbs to give surface carbonate). Here, the variation of the absorbance of the infrared bands with the polarization of the probe beam indicated that the surface CO2 phase was highly oriented. [Pg.636]

A RIKES experunent is essentially identical to that of CW CARS, except the probe laser need not be tunable. The probe beam is linearly polarized at 0° (—>), while the polarization of the tunable pump beam is controlled by a linear polarizer and a quarter waveplate. The pump and probe beams, whose frequency difference must match the Raman frequency, are overlapped in the sample (just as in CARS). The strong pump beam propagating tlirough a nonlinear medium induces an anisotropic change in the refractive mdices seen by tlie weaker probe wave, which alters the polarization of a probe beam [96]. The signal field is polarized orthogonally to the probe laser and any altered polarization may be detected as an increase in intensity transmitted tlirough a crossed polarizer. When the pump beam is Imearly polarized at 45° y), contributions... [Pg.1207]

Figure B2.5.8. Schematic representation of laser-flash photolysis using the pump-probe technique. The beam splitter BS splits the pulse coming from the laser into a pump and a probe pulse. The pump pulse initiates a reaction in the sample, while the probe beam is diverted by several mirrors M tluough a variable delay line. Figure B2.5.8. Schematic representation of laser-flash photolysis using the pump-probe technique. The beam splitter BS splits the pulse coming from the laser into a pump and a probe pulse. The pump pulse initiates a reaction in the sample, while the probe beam is diverted by several mirrors M tluough a variable delay line.
The detector D monitors the absorption of the probe beam as a function of the delay between the pulses given by xHc, where c is the speed of light and v is the difference between the optical path travelled by the probe and by the pump pulse. Adapted from [110],... [Pg.2127]

Ultrafast TRCD has also been measured in chemical systems by incoriDorating a PEM into the probe beam optics of a picosecond laser pump-probe absorjDtion apparatus [35]. The PEM resonant frequency is very low (1 kHz) in these experiments, compared with the characteristic frequencies of ultrafast processes and so does not interfere with the detection of ultrafast CD changes. [Pg.2966]

The gates referred to above can be created in various ways. For example, suppose that the probe beam goes tlirough the sample, but only half of its physical width (in the sample) is crossed with the pump beam. Now, if we have two photodiodes, one can measure the intensify of the perturbed part of the probe beam, whilst the second measures the unperturbed part as a result of creating spatial gates, the two recorded output signals can be used to measure the... [Pg.3028]

Spectroscopic examination of light scattered from a monochromatic probe beam reveals the expected Rayleigh, Mie, and/or Tyndall elastic scattering at unchanged frequency, and other weak frequencies arising from the Raman effect. Both types of scattering have appHcations to analysis. [Pg.318]

Fluorometry and Phosphorimetry. Modem spectrofluorometers can record both fluorescence and excitation spectra. Excitation is furnished by a broad-band xenon arc lamp foUowed by a grating monochromator. The selected excitation frequency, is focused on the sample the emission is coUected at usuaUy 90° from the probe beam and passed through a second monochromator to a photomultiplier detector. Scan control of both monochromators yields either the fluorescence spectmm, ie, emission intensity as a function of wavelength X for a fixed X, or the excitation spectmm, ie, emission intensity at a fixed X as a function of X. Fluorescence and phosphorescence can be distinguished from the temporal decay of the emission. [Pg.319]

In Surface Analysis by Laser Ionization (SALI), a probe beam such as an ion beam, electron beam, or laser is directed onto a surfiice to remove a sample of material. An untuned, high-intensity laser beam passes parallel and close to but above the sur-fiice. The laser has sufficient intensity to induce a high degree of nonresonant, and hence nonselective, photoionization of the vaporized sample of material within the laser beam. The nonselectively ionized sample is then subjected to mass spectral analysis to determine the nature of the unknown species. SALI spectra accurately reflect the surface composition, and the use of time-of-flight mass spectrometers provides fast, efficient and extremely sensitive analysis. [Pg.42]

Auger electron spectroscopy (AES) is a technique used to identify the elemental composition, and in many cases, the chemical bonding of the atoms in the surface region of solid samples. It can be combined with ion-beam sputtering to remove material from the surface and to continue to monitor the composition and chemistry of the remaining surface as this surface moves into the sample. It uses an electron beam as a probe of the sample surface and its output is the energy distribution of the secondary electrons released by the probe beam from the sample, although only the Ai er electron component of the secondaries is used in the analysis. [Pg.310]

A commonly used form of internal modulation is differential reflectometry, in which the reflectance of the sample under investigation (or a portion of it) is compared to a standard material. This can be accomplished either by holding the sample stationary and scanning the probe beam between two regions or by holding the l t spot fixed and moving the sample. ... [Pg.390]

For thin-film samples, abrupt changes in refractive indices at interfrees give rise to several complicated multiple reflection effects. Baselines become distorted into complex, sinusoidal, fringing patterns, and the intensities of absorption bands can be distorted by multiple reflections of the probe beam. These artifacts are difficult to model realistically and at present are probably the greatest limiters for quantitative work in thin films. Note, however, that these interferences are functions of the complex refractive index, thickness, and morphology of the layers. Thus, properly analyzed, useful information beyond that of chemical bonding potentially may be extracted from the FTIR speara. [Pg.425]

All the techniques discussed here involve the atomic nucleus. Three use neutrons, generated either in nuclear reactors or very high energy proton ajccelerators (spallation sources), as the probe beam. They are Neutron Diffraction, Neutron Reflectivity, NR, and Neutron Activation Analysis, NAA. The fourth. Nuclear Reaction Analysis, NRA, uses charged particles from an ion accelerator to produce nuclear reactions. The nature and energy of the resulting products identify the atoms present. Since NRA is performed in RBS apparatus, it could have been included in Chapter 9. We include it here instead because nuclear reactions are involved. [Pg.645]

Nearly all these techniques involve interrogation of the surface with a particle probe. The function of the probe is to excite surface atoms into states giving rise to emission of one or more of a variety of secondary particles such as electrons, photons, positive and secondary ions, and neutrals. Because the primary particles used in the probing beam can also be electrons or photons, or ions or neutrals, many separate techniques are possible, each based on a different primary-secondary particle combination. Most of these possibilities have now been established, but in fact not all the resulting techniques are of general application, some because of the restricted or specialized nature of the information obtained and others because of difficult experimental requirements. In this publication, therefore, most space is devoted to those surface analytical techniques that are widely applied and readily available commercially, whereas much briefer descriptions are given of the many others the use of which is less common but which - in appropriate circumstances, particularly in basic research - can provide vital information. [Pg.2]

In the continuous wave (CW) experimental setup a sample is constantly illuminated by a probe beam and the steady state change in the transmission is detected (see Fig. 7-1). An argon ion laser has been used to generate the pump beam and the probe beam was from an incandescent lamp (tungsten or others), producing a broad spectrum (0.5 to 5 pm) [6]. Both pump and probe beams are directed onto the sample film and the transmitted probe light is collected, filtered through a monochromator, and detected by a photodetector. Both the pump and the probe... [Pg.108]

In many respects the time-resolved pump-probe technique is similar to the CW counterpart. The use of pulsed laser light permits direct probing of both the magnitude of the PA and its dynamics. The experimental arrangement is practically the same as for the CW version, i.e., both pump and probe beams are focused and overlapped onto same spot on a sample. In addition, the pump and probe pulses are synchronized so that the lime interval t between them is constant and confined to a certain time range (in our case up to 3 ns). [Pg.111]

A critical difference between the transient and CW measurements is that while the CW probe source uniformly illuminates the sample, both the transient pump and probe beams have Gaussian distributions. Equation (7.7) can be rewritten for the transient case as ... [Pg.111]


See other pages where Probe beam is mentioned: [Pg.163]    [Pg.695]    [Pg.696]    [Pg.697]    [Pg.770]    [Pg.306]    [Pg.1208]    [Pg.1979]    [Pg.1982]    [Pg.2949]    [Pg.2955]    [Pg.2964]    [Pg.2966]    [Pg.3001]    [Pg.3028]    [Pg.3028]    [Pg.3028]    [Pg.3029]    [Pg.512]    [Pg.549]    [Pg.129]    [Pg.397]    [Pg.315]    [Pg.319]    [Pg.1]    [Pg.2]    [Pg.57]    [Pg.561]    [Pg.564]    [Pg.112]    [Pg.116]    [Pg.121]   
See also in sourсe #XX -- [ Pg.73 ]

See also in sourсe #XX -- [ Pg.64 , Pg.81 , Pg.82 , Pg.89 , Pg.130 , Pg.140 , Pg.144 , Pg.225 ]




SEARCH



Beam Probing

Beam-probe techniques

Electron beam probe

Laser-probe beam, schematic depiction

Light continuum probe beam

Probe Beam Deflection Technique (PBD)

Probe beam deflection

Probe beam deflection (PBD)

Probe beam deflection technique

Probe beam linearly polarized

© 2024 chempedia.info