Testing and perfection of the failed fuel monitoring systems. [Pg.91]

The gas turbine is a complex system. A typical control system with hierarchic levels of automation is shown in Figure 19-3. The control system at the plant level consists of a D-CS system, which in many new installations is connected to a condition monitoring system and an optimization system. The D-CS system is what is considered to be a plant level system and is connected to the three machine level systems. It can, in some cases, also be connected to functional level systems such as lubrication systems and fuel handling systems. In those cases, it would give a signal of readiness from those systems to the machine level systems. The condition monitoring system... [Pg.636]

A Btu meter may be used in the fuel-quality system as an aid in determining turbine system efficiency. A water capacitance probe is used for detection of water in the fuel line. A water-detecting device can be incorporated into the corrosion monitoring system. This monitoring device is based on detection of changes in the dielectric constant of unknown fluid components... [Pg.671]

Five projects were initiated to manage spent nuclear fuel the development of a dual-purpose transport and storage cask a cask trans-shipment facility a cask de-watering and fuel drying system a centralized radio-ecological monitoring system for the cask... [Pg.111]

Small installations in the US SO2 program are generally exempt from the requirement to install a Continuous Emissions Monitoring System and instead report emissions based on fuel use and engineering calculations. [Pg.343]

Their operation depends on the absence of poisons such as lead compounds, and on a fuel injection system that provides an almost perfect stoichiometric ratio of fuel and oxygen to the engine this is achieved by a feedback system using a sensor that monitors the 02 content of the exhaust gases,... [Pg.338]

Williams Bio-Energy will host the industrial site for this demonstration. Williams works with Nuvera and Caterpillar to provide them with site electrical load requirements. They will prepare the site to ensure that the fuel cell system links to their power network and will supply ethanol fuel and other utilities. During the demonstration, Williams personnel will monitor and service equipment and permit visitors to witness the demonstration in comfort and safety. [Pg.291]

Hydrogen reformate gas powered fuel cell systems require sensors for carbon monoxide level monitoring and feedback control. [Pg.468]

The fuel cell-powered scooter project has provided valuable insights into fuel cell operation under real-world conditions as well as monitoring and control strategies to maximize power and efficiency. The electronics developed for the project have found dual use with other fuel cell testing systems. Additionally, the fuel cell-powered scooter has proven valuable as a way to illustrate and demystify fuel cell systems, and as a public relations tool to promote alternative energy research at Los Alamos National Laboratory. [Pg.529]

VI.A. 1 Gallium Nitride Integrated Gas/Temperature Sensors for Fuel Cell System Monitoring for Hydrogen and Carbon Monoxide... [Pg.573]

In nearly all industrial combustion systems, the fuel flow rate is measured. In many cases it must be measured in order to calculate emissions according to regulatory requirements. For example, some air permits are based on a given maximum fuel flow rate. For some applications that do not have continuous emissions monitoring systems, an emission factor may be assumed using EPA AP-42 [42]. These factors... [Pg.162]

The USS Essex and three other LHD-class amphibious assault ships utilize furnace cameras to observe flame patterns and identify potential problems in a boiler combustion monitoring system and also monitor a pushbutton igniter-control system. Previously, a sailor monitored the fires through a small porthole, and an engineer in a flame-resistant jacket lit the boilers with a torch. If unburned fuel was in the boiler, explosions could occur. [Pg.365]

Some of the stringent requirements on the storage pools are eff < 0.95 (even if unused fuel elements are introduced), earthquake safety, no possible water loss, water level automatically kept constant, adequate leakage and radiation monitoring systems, water tenqjerature < 65°C, acceptably low radiation level in working areas, etc. [Pg.601]

Over a total period of operation the core sub-assembly cleaning system performance was sufficiently reliable. Like with the fuel handling system it is the mechanism position indication and control system that has mostly been a trouble contributor with an impact from the process control and monitoring system. The process configuration itself is unsatisfactory since the manifold of the steam-water cleaning cells is combined with the equipment cleaning system (large capacities, risk of overflows and leaks, etc...). [Pg.108]

The Gamma Monitor System detects fuel element ruptures by continuously monitoring effluent water from each rear cross-header. A gamma sensitive Ion chamber la revolved past the respective continuous streams and measures the magnitude of the gamma emission. Vlstial fluid audible Alarms eumunclate if the trip points are exceeded. radiation profile of the crossheaders Is plotted on multipoint recorders. [Pg.38]

An alternative could be a fuel cell module. In order to keep the design simple and the operation reliable it is sufficient to use as main components, a fuel cell, an oxygen gas cylinder, an H2 gas cylinder, control valves and cooling. The functionality could be easily tested at any time when installed by an appropriate monitoring system (Fig. 5.6). [Pg.117]

Laguna Verde Unit two started three fuel cycles after the unit one, during the construction process and start-up program of unit one some of the components of unit two were used as spare parts of unit one, for that reason during construction program of unit two such components were required but such components were out of the market, companies closed, or new advanced systems were developed for such purposes. That was the case of the Transverse In core Probe (TIP), Source (SRNM) and Intermediate range (IRNM) neutron monitoring systems. [Pg.103]

The further part of our research has been focused on monitoring of failures within the fuel cell system during operation. There has been no larger application of fuel cells so far, so there is no information of such nature available. Any databases on failures and reli-abihty data would be of great contribution for the purpose of application of fuel cells in the classic field of electric power faciUties. That would help optimise the maintenance procedure, to reduce all the cost associated therewith and to increase the overall reliabdity of electric power supply from such sources. [Pg.1586]

The evaluation was conducted with all the failures subject to consideration as these occurred within the period of monitoring of 41 hours and 27 minutes. The period included both the measurement of particular load characteristics as well as long-term operation at rated power (the supply of electric power into the distribution network via inverter). The NEXA system experienced twelve failures within the period monitored. There were five failures due to the low pressure of fuel at the fuel cell system inlet, four failures due to high stack current and one failure caused by the low stack voltage (Fig. 6) and there were two failures due to causes within the distribution network (or the inverter). The latter failures did not induce the automatic deactivation of the fuel cell system yet only temporary interruption of the supply into the distribution network. [Pg.1586]

The failure monitoring was conducted within the period of 41 hours and 27 minutes. That led to estab-hshment of the failure rate (6.95 failures per day) and the mean repair time (1.81 minutes). The failure rate is high, yet this high number is also due to the frequent initiation of the fuel cell system, frequent load with the nominal power output, occasional overloads and fluctuating voltage within the distribution network at the inverter connection point. The values of failure rate and the mean repair time shall be specified using... [Pg.1587]

The general philosophy to be followed and major features of I feC systems has been decided. Design of control room is under review and man-machine interface is under study. Conceptual design of systems for core temperature monitoring, flow measurement in primary sodium, reactor protection, failed fuel detection and SG leak detection have been prepared. Flux monitoring and failed fuel detection systems are under discussion. [Pg.92]

The major subassemblies of the CLEM include the grapple drive system, cask body modules, service platforms, a movable closure valve that mates with the floor valve, the cold-wall assembly, and a seal monitoring system. It also has a variety of special features for other required test-reactor operations such as moving test assemblies from the closed loops to the examination cell and assisting of the disassembly of the fuel within the cell. [Pg.79]


See other pages where Fuel monitoring system is mentioned: [Pg.520]    [Pg.272]    [Pg.366]    [Pg.307]    [Pg.315]    [Pg.266]    [Pg.24]    [Pg.169]    [Pg.15]    [Pg.170]    [Pg.507]    [Pg.806]    [Pg.527]    [Pg.528]    [Pg.576]    [Pg.555]    [Pg.137]    [Pg.228]    [Pg.69]    [Pg.45]    [Pg.15]    [Pg.930]    [Pg.77]    [Pg.127]    [Pg.1587]    [Pg.126]   


SEARCH



Fuel monitoring system water content monitor

Fuel system

Monitor system

Monitoring system

© 2024 chempedia.info