Tandem mass spectrometry instruments

A. Tandem Mass Spectrometry Instrumentation and Activation Techniques... [Pg.91]

Brain et al. [137] reported a tandem mass spectrometry (MS-MS) procedure by which a direct measurement from an n-pentane extract of a surfactant is possible. This procedure is excellent from the standpoint of sensitivity and simplicity of sample preparation but is not commonly applied because of the need of an MS-MS instrument. [Pg.448]

All previous discussion has focused on sample preparation, i.e., removal of the targeted analyte(s) from the sample matrix, isolation of the analyte(s) from other co-extracted, undesirable sample components, and transfer of the analytes into a solvent suitable for final analysis. Over the years, numerous types of analytical instruments have been employed for this final analysis step as noted in the preceding text and Tables 3 and 4. Overall, GC and LC are the most often used analytical techniques, and modern GC and LC instrumentation coupled with mass spectrometry (MS) and tandem mass spectrometry (MS/MS) detection systems are currently the analytical techniques of choice. Methods relying on spectrophotometric detection and thin-layer chromatography (TLC) are now rarely employed, except perhaps for qualitative purposes. [Pg.439]

Specifically for triazines in water, multi-residue methods incorporating SPE and LC/MS/MS will soon be available that are capable of measuring numerous parent compounds and all their relevant degradates (including the hydroxytriazines) in one analysis. Continued increases in liquid chromatography/atmospheric pressure ionization tandem mass spectrometry (LC/API-MS/MS) sensitivity will lead to methods requiring no aqueous sample preparation at all, and portions of water samples will be injected directly into the LC column. The use of SPE and GC or LC coupled with MS and MS/MS systems will also be applied routinely to the analysis of more complex sample matrices such as soil and crop and animal tissues. However, the analyte(s) must first be removed from the sample matrix, and additional research is needed to develop more efficient extraction procedures. Increased selectivity during extraction also simplifies the sample purification requirements prior to injection. Certainly, miniaturization of all aspects of the analysis (sample extraction, purification, and instrumentation) will continue, and some of this may involve SEE, subcritical and microwave extraction, sonication, others or even combinations of these techniques for the initial isolation of the analyte(s) from the bulk of the sample matrix. [Pg.445]

Instrumentation Liquid chromatography/tandem mass spectrometry (LC/ MS/MS). [Pg.509]

The need to understand the fate of pesticides in the environment has necessitated the development of analytical methods for the determination of residues in environmental media. Adoption of methods utilizing instrumentation such as gas chro-matography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS), liquid chromatography/tandem mass spectrometry (LC/MS/MS), or enzyme-linked immunosorbent assay (ELISA) has allowed the detection of minute amounts of pesticides and their degradation products in environmental samples. Sample preparation techniques such as solid-phase extraction (SPE), accelerated solvent extraction (ASE), or solid-phase microextraction (SPME) have also been important in the development of more reliable and sensitive analytical methods. [Pg.605]

The most widely regarded approach to accomplish the determination of as many pesticides as possible in as few steps as possible is to use MS detection. MS is considered a universally selective detection method because MS detects all compounds independently of elemental composition and further separates the signal into mass spectral scans to provide a high degree of selectivity. Unlike GC with selective detectors, or even atomic emission detection (AED), GC/MS may provide acceptable confirmation of the identity of analytes without the need for further information. This reduces the need to re-inject a sample into a separate GC system (usually GC/MS) for pesticide confirmation. Through the use of selected ion monitoring (SIM), efficient ion-trap or quadrupole devices, and/or tandem mass spectrometry (MS/MS), modern GC/MS instruments provide LODs similar to or lower than those of selective detectors, depending on the analytes, methods, and detectors. [Pg.762]

Principles and Characteristics Analytical multistage mass spectrometry (MSn) relies on the ability to activate and dissociate ions generated in the ion source in order to identify or obtain structural information about an unknown compound and to analyse mixtures by exploiting two or more mass-separating steps. A basic instrument for the currently most used form, tandem mass spectrometry (MS/MS), consists of a combination of two mass analysers with a reaction region between them. While a variety of instrument set-ups can be used in MS/MS, there is a single basic concept involved the measurement of the m/z of ions before and after a reaction in the mass spectrometer the reaction involves a change in mass and can be represented as ... [Pg.398]

The instrumental analysis for the identification of UV filters degradation products formed during the fungal treatment process was performed by means of HPLC coupled to tandem mass spectrometry using a hybrid quadrupole-time-of-flight mass spectrometer (HPLC-QqTOF-MS/MS). Chromatographic separation was achieved on a Hibar Purospher STAR HR R-18 ec. (50 mm x 2.0 mm, 5 pm, from Merck). In the optimized method, the mobile phase consisted of a mixture of HPLC grade water and acetonitrile, both with 0.15% formic acid. The injection volume was set to 10 pL and the mobile phase flow-rate to 0.3 mL/min. [Pg.225]

Multiple mass analyzers exist that can perform tandem mass spectrometry. Some use a tandem-in-space configuration, such as the triple quadrupole mass analyzers illustrated (Fig.3.9). Others use a tandem-in-time configuration and include instruments such as ion-traps (ITMS) and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS or FTMS). A triple quadrupole mass spectrometer can only perform the tandem process once for an isolated precursor ion (e.g., MS/MS), but trapping or tandem-in-time instruments can perform repetitive tandem mass spectrometry (MS ), thus adding n 1 degrees of structural characterization and elucidation. When an ion-trap is combined with HPLC and photodiode array detection, the net result is a profiling tool that is a powerful tool for both metabolite profiling and metabolite identification. [Pg.47]


See other pages where Tandem mass spectrometry instruments is mentioned: [Pg.66]    [Pg.108]    [Pg.50]    [Pg.466]    [Pg.129]    [Pg.129]    [Pg.129]    [Pg.131]    [Pg.133]    [Pg.135]    [Pg.137]    [Pg.139]    [Pg.141]    [Pg.144]    [Pg.308]    [Pg.66]    [Pg.108]    [Pg.50]    [Pg.466]    [Pg.129]    [Pg.129]    [Pg.129]    [Pg.131]    [Pg.133]    [Pg.135]    [Pg.137]    [Pg.139]    [Pg.141]    [Pg.144]    [Pg.308]    [Pg.153]    [Pg.1029]    [Pg.62]    [Pg.104]    [Pg.25]    [Pg.55]    [Pg.311]    [Pg.426]    [Pg.576]    [Pg.736]    [Pg.818]    [Pg.392]    [Pg.401]    [Pg.402]    [Pg.406]    [Pg.411]    [Pg.25]    [Pg.255]    [Pg.368]    [Pg.48]    [Pg.277]    [Pg.175]    [Pg.217]    [Pg.139]    [Pg.430]   
See also in sourсe #XX -- [ Pg.129 ]




SEARCH



Mass spectrometry instrument

Mass spectrometry instrumentation

Mass spectrometry tandem

Spectrometry instrumentation

Tandem mass spectrometry instrumentation

Tandem spectrometry