Mobile phase flow

This relation holds for column systems, and, in a more general concept, also for planar systems in the first case L is the length of the column, and in the second case L designates the distance of the front of the chromatogram from the level of development liquid. In gas chromatography the situation is more complex, due to the high compressibility of the mobile phase. It holds here that [Pg.17]

With respect to equations 36 and 38 the basic retention equation (see equation 9) for gas chromatography can be defined more rigorously as [Pg.18]

Equation 39 has been derived under the assumption that k is independent of pressure, however, this condition need not always be fulfilled to a sufficient extent. [Pg.18]


An eluted solute was originally identified from its corrected retention volume which was calculated from its corrected retention time. It follows that the accuracy of the measurement depended on the measurement and constancy of the mobile phase flow rate. To eliminate the errors involved in flow rate measurement, particularly for mobile phases that were compressible, the capacity ratio of a solute (k ) was introduced. The capacity ratio of a solute is defined as the ratio of its distribution coefficient to the phase ratio (a) of the column, where... [Pg.26]

It is clear that the separation ratio is simply the ratio of the distribution coefficients of the two solutes, which only depend on the operating temperature and the nature of the two phases. More importantly, they are independent of the mobile phase flow rate and the phase ratio of the column. This means, for example, that the same separation ratios will be obtained for two solutes chromatographed on either a packed column or a capillary column, providing the temperature is the same and the same phase system is employed. This does, however, assume that there are no exclusion effects from the support or stationary phase. If the support or stationary phase is porous, as, for example, silica gel or silica gel based materials, and a pair of solutes differ in size, then the stationary phase available to one solute may not be available to the other. In which case, unless both stationary phases have exactly the same pore distribution, if separated on another column, the separation ratios may not be the same, even if the same phase system and temperature are employed. This will become more evident when the measurement of dead volume is discussed and the importance of pore distribution is considered. [Pg.28]

The column used in the upper chromatogram was 24 cm long, 4.6 mm I.D. the solvent was tetrahydrofuran, the solute benzene and the flow rate 1 ml/min. The column used in the lower chromatogram was 1 m long, 1 mm I.D. using the same solvent and solute but at a mobile phase flow rate of 40 ml/min. It is seen that the reduction in cell volume has a dramatic effect on peak shape. The large 25 pi cell... [Pg.307]

It follows from equation (2) that the sample load will increase as the square of the column radius and thus the column radius is the major factor that controls productivity. Unfortunately, increasing the column radius will also increase the volume flow rate and thus the consumption of solvent. However, both the sample load and the mobile phase flow rate increases as the square of the radius, and so the solvent consumption per unit mass of product will remain the same. [Pg.432]

The mechanism of separation is the same for Zorbax PSM columns as it is for other types of SEC columns. As the mobile phase flows through the column, large molecules are forced down the column at faster rates than small molecules because the large molecules have less access to the column volume inside the pores. Consequently, molecules that are too large to permeate any of the pore... [Pg.77]

Step 1) Divert initial portion of chromatogram to waste. The sample is injeeted with the valve A (left) elosed mobile phase flows through the preeolumn to valve B (right), whieh is opened to waste. [Pg.123]

This velocity gradient arises from the pressure gradient necessary to create mobile-phase flow. The pressure drops as we travel from the column inlet to the... [Pg.164]

Although the problems associated with septum injectors can be eliminated by using stop-flow septumless injection, currently the most widely used devices in commercial chromatographs are the microvolume sampling valves (Fig. 8.3) which enable samples to be introduced reproducibly into pressurised columns without significant interruption of the mobile phase flow. The sample is loaded at atmospheric pressure into an external loop in the valve and introduced into the mobile phase by an appropriate rotation of the valve. The volume of sample introduced, ranging from 2 piL to over 100 /iL, may be varied by changing... [Pg.222]

Column Column Length Column Diameter Column Packing Mobile Phase Flow Rate Detector Sample Volume... [Pg.203]

Mobile Phase Flow Rate Detector Sample Volume... [Pg.228]

Unfortunately, neither the computer nor the potentiometric recorder measures the primary variable, volume of mobile phase, but does measure the secondary variable, time. This places stringent demands on the LC pump as the necessary accurate and proportional relationship between time and volume flow depends on a constant flow rate. Thus, peak area measurements should never be made unless a good quality pump is used to control the mobile phase flow rate. Furthermore, the pump must be a constant flow pump and not a constant pressure pump. [Pg.266]

The time taken for an analyte to elute from a chromatographic column with a particular mobile phase is termed its retention time, fan- Since this will vary with column length and mobile phase flow rate, it is more useful to use the capacity factor, k. This relates the retention time of an analyte to the time taken by an unretained compound, i.e. one which passes through the column without interacting with the stationary phase, to elute from the column under identical conditions (to). This is represented mathematically by the following equation ... [Pg.35]

Figure 4.9 Schematics of electrospray LC-MS interfaces with (a) a heated capillary and (b) a heated block to allow high mobile-phase flow rates. From applications literature published by (a) Thermofinnigan, Kernel Hempstead, UK, and (b) Micromass UK Ltd, Manchester, UK, and reproduced with permission. Figure 4.9 Schematics of electrospray LC-MS interfaces with (a) a heated capillary and (b) a heated block to allow high mobile-phase flow rates. From applications literature published by (a) Thermofinnigan, Kernel Hempstead, UK, and (b) Micromass UK Ltd, Manchester, UK, and reproduced with permission.
Mobile phase flow rates from nlmin to in excess of 1 mlmin can be used with appropriate hardware, thus allowing conventional and microbore columns to be employed. [Pg.179]

In this study, the effect of mobile-phase flow rate, or more accurately, the rate of flow of liquid into the LC-MS interface, was not considered but as has been pointed out earlier in Sections 4.7 and 4.8, this is of great importance. In particular, it determines whether electrospray ionization functions as a concentration-or mass-flow-sensitive detector and may have a significant effect on the overall sensitivity obtained. Both of these are of great importance when considering the development of a quantitative analytical method. [Pg.192]

Stationary phase That part of the chromatographic system with which the analytes interact, over which the mobile phase flows. [Pg.311]

Figure 4-2. Size-exclusion chromatography. A A mixture of large molecules (diamonds) and small molecules (circles) are applied to the top of a gel filtration column. B Upon entering the column, the small molecules enter pores in the stationary phase matrix from which the large molecules are excluded. C As the mobile phase flows down the column, the large, excluded molecules flow with it while the small molecules, which are temporarily sheltered from the flow when inside the pores, lag farther and farther behind. Figure 4-2. Size-exclusion chromatography. A A mixture of large molecules (diamonds) and small molecules (circles) are applied to the top of a gel filtration column. B Upon entering the column, the small molecules enter pores in the stationary phase matrix from which the large molecules are excluded. C As the mobile phase flows down the column, the large, excluded molecules flow with it while the small molecules, which are temporarily sheltered from the flow when inside the pores, lag farther and farther behind.
Columns for each code are listed in the direction of mobile phase flow ... [Pg.153]

One mobile phase contains polyethylene oxide = SOOfiOO) (For details see Table II). Mobile phase flow rate 4.2 mL min water mobile phase containing poly-ethylene oxide (M - 300,000) (A) 0.0I67M MgSO (pH - 2.28) ... [Pg.274]

In situ loading during the chromatographic development. By this method a continuous gradient of the hquid stationary phase is created on the PLC layer in the direction of the mobile phase flow. This is achieved by developing the plate with a suitable multieomponent solvent system. [Pg.54]


See other pages where Mobile phase flow is mentioned: [Pg.246]    [Pg.1539]    [Pg.191]    [Pg.196]    [Pg.264]    [Pg.366]    [Pg.78]    [Pg.156]    [Pg.306]    [Pg.218]    [Pg.188]    [Pg.277]    [Pg.34]    [Pg.150]    [Pg.197]    [Pg.650]    [Pg.234]    [Pg.278]    [Pg.279]    [Pg.280]    [Pg.280]    [Pg.282]    [Pg.7]    [Pg.122]    [Pg.133]    [Pg.143]    [Pg.340]   


SEARCH



Capillary electrochromatography mobile phase electroosmotic flow

Effects of Mobile Phase Choice and Flow Parameters

Flow Programming with a Compressible Mobile Phase

Flow and Diffusion in the Mobile Phase

Flow rate of mobile phase

Flow-rate of the mobile-phase

Forced-flow mobile phase velocity

Mobile phase flow rate

Mobile phases, flow calibration

Noise mobile phase/flow temperature

Phase flow