Instrumentation Provided

Implement preuse verification and calibration Periodically flush/purge of instruments Provide recirculation during idle periods... [Pg.119]

The STEM instrument itself can produce highly focused high-intensity beams down to 2 A if a field-emission source is used. Such an instrument provides a higher spatial resolution compositional analysis than any other widely used technique, but to capitalize on this requires very thin samples, as stated above. EELS and EDS are the two composition techniques usually found on a STEM, but CL, and even AES are sometimes incorporated. In addition simultaneous crystallographic information can be provided by diffraction, as in the TEM, but with 100 times better spatial resolution. The combination of diffraction techniques and analysis techniques in a TEM or STEM is termed Analytical Electron Microscopy, AEM. A well-equipped analytical TEM or STEM costs well over 1,000,000. [Pg.119]

There are three types of instruments that provide STEM imaging and analysis to various degrees the TEM/STEM, in which a TEM instrument is modified to operate in STEM mode the SEM/STEM, which is a SEM instrument with STEM imaging capabilities and dedicated STEM instruments that are built expressly for STEM operation. The STEM modes of TEM/STEM and SEM/STEM instruments provide useful information to supplement the main TEM and SEM modes, but only the dedicated STEM with a field emission electron source can provide the highest resolution and elemental sensitivity. [Pg.162]

Linear polarization instruments provide an instantaneous corrosion-rate data, by utilizing polarization phenomena. These instruments are commercially available as two-electrode Corrater and three electrode Pairmeter (Figure 4-472). The instruments are portable, with probes that can be utilized at several locations in the drilling fluid circulatory systems. In both Corrater and Pairmeter, the technique involves monitoring electrical potential of one of the electrodes with respect to one of the other electrodes as a small electrical current is applied. The amount of applied current necessary to change potential (no more than 10 to 20 mV) is proportional to corrosion intensity. The electronic meter converts the amount of current to read out a number that represents the corrosion rate in mpy. Before recording the data, sufficient time should be allowed for the electrodes to reach equilibrium with the environment. The corrosion-rate reading obtained by these instruments is due to corrosion of the probe element at that instant [184]. [Pg.1312]

Most infrared monitoring systems or instruments provide special filters that can be used to avoid the negative effects of atmospheric attenuation of infrared data. However the plant user must recognize the specific factors that will affect the accuracy of the infrared data and apply the correct filters or other signal conditioning required negating that specific attenuating factor or factors. [Pg.799]

This type of infrared instrument provides a single dimensional scan or line of comparative radiation. While this type of instrument provides a somewhat larger field of view, i.e. area of machine surface, it is limited in predictive maintenance applications. [Pg.799]

Instruments providing simultaneous measurement of a number of parameters on multi-element probes have been developed, including potential noise , galvanic coupling, potential monitoring, and a.c. impedance . [Pg.37]

Today, modern instrumentation provides much more direct evidence of atoms (Fig. B.3). There is no longer any doubt that atoms exist and that they are the units that make up the elements. In fact, chemists use the existence of atoms as the definition of an element an element is a substance composed of only one kind of atom. By 2006, 111 elements had been discovered or created but in some cases in only very small amounts. For instance, when element 110 was made, only two atoms were produced, and even they lasted for only a tiny fraction of a second before disintegrating. [Pg.40]

Other analyzers such as the Gilford Automated Enzyme Analyzer and the LKB-8600 Reaction Rate Analyzer analyze discrete samples one at a time. These instruments provide kinetic analyses, digital data reduction at the time each sample is analyzed, and excellent electronic and optical characteristics. Recently, Atwood has developed kinetic enzyme analyzers which require only 9 seconds for measuring an enzyme activity, using highly stable and sensitive electronic circuits (12). This short read out time allows a large number of samples to be processed by one instrument in an automated mode. [Pg.182]

The most widely regarded approach to accomplish the determination of as many pesticides as possible in as few steps as possible is to use MS detection. MS is considered a universally selective detection method because MS detects all compounds independently of elemental composition and further separates the signal into mass spectral scans to provide a high degree of selectivity. Unlike GC with selective detectors, or even atomic emission detection (AED), GC/MS may provide acceptable confirmation of the identity of analytes without the need for further information. This reduces the need to re-inject a sample into a separate GC system (usually GC/MS) for pesticide confirmation. Through the use of selected ion monitoring (SIM), efficient ion-trap or quadrupole devices, and/or tandem mass spectrometry (MS/MS), modern GC/MS instruments provide LODs similar to or lower than those of selective detectors, depending on the analytes, methods, and detectors. [Pg.762]

Tables 6.27 and 6.31 show the main characteristics of ToF-MS. ToF-MS shows an optimum combination of resolution and sensitivity. ToF-MS instruments provide up to 40000 spectra s-1, a mass range exceeding 100000 (in principle unlimited), a resolution of 5000, and peak widths as short as 200 ms. This is better than quadruples and most ion traps can handle. Unlike the quadrupole-type instrument, the detector is detecting every introduced ion (high duty factor). This leads to a 20- to 100-times increase in sensitivity, compared to QMS used in scan mode. The mass range increases quadratically with the time range that is recorded. Only the ion source and detector impose the limits on the mass range. Mass accuracy in ToF-MS is sufficient to gain access to the elemental composition of a molecule. A single point is sufficient for the mass calibration of the instrument. ToF mass spectra are commonly calibrated using two known species, aluminium (27 Da) and coronene (300 Da). ToF is well established in combination with quite different ion sources like in SIMS, MALDI and ESI. Tables 6.27 and 6.31 show the main characteristics of ToF-MS. ToF-MS shows an optimum combination of resolution and sensitivity. ToF-MS instruments provide up to 40000 spectra s-1, a mass range exceeding 100000 (in principle unlimited), a resolution of 5000, and peak widths as short as 200 ms. This is better than quadruples and most ion traps can handle. Unlike the quadrupole-type instrument, the detector is detecting every introduced ion (high duty factor). This leads to a 20- to 100-times increase in sensitivity, compared to QMS used in scan mode. The mass range increases quadratically with the time range that is recorded. Only the ion source and detector impose the limits on the mass range. Mass accuracy in ToF-MS is sufficient to gain access to the elemental composition of a molecule. A single point is sufficient for the mass calibration of the instrument. ToF mass spectra are commonly calibrated using two known species, aluminium (27 Da) and coronene (300 Da). ToF is well established in combination with quite different ion sources like in SIMS, MALDI and ESI.
Ion trap MS is particularly suited for chemical structure elucidation, as it allows for simultaneous ion storage, ion activation and fragmentation, and product ion analysis. The fragmentation pathway of selected ions and the fragmentation products provide information on the molecular structure. Compared with triple-quadrupole and especially with sector instruments, the ion trap instrument provides more efficient conversion of precursor ion into product ions. However, the CID process via resonance excitation, although quite efficient in terms of conversion yield, generally results in only one (major) product ion in the product-ion mass spectrum. MS/MS with a quadrupole ion trap offers a number of advantages ... [Pg.402]

Several all-in-one tablet testers are currently available that measure weight, thickness, diameter, and hardness of tablets. In addition these instruments provide digital storage and calculation of statistical parameters and allow for rapid feedback during the tableting process so that the tableting equipment can be adjusted accordingly with minimal downtime. ... [Pg.328]

In addition, global warming is characterized by other important features that imply some difficulties in the implementation of the instruments provided by the standard economic theory of policy choice. First, we cannot determine with certainty both the dimension and the timing of climate change and the costs of the abatement of emissions. Second, the effects of GHG concentration in the atmosphere on climate are intergenerational and persistent across... [Pg.36]

According to Galilei, the observation of natural phenomena using suitable measuring instruments provides certain numerical values which must be related to one another the solution of the equations derived from the numbers allows us to forecast future developments. This led to the misunderstanding that knowledge could only be obtained in such a manner. The result was deterministic belief, which was disproved for microscopic objects by Heisenberg s uncertainty principle. On the macroscopic scale, however, it appeared that the deterministic approach was still valid. Determinism was only finally buried when deterministic chaos was discovered. [Pg.243]

Instrumentation provides the various indications used to operate a nuclear facility. In some cases, operators record these indications for use in day-to-day operation of the facility. The information recorded helps the operator evaluate the current condition of the system and take actions if the conditions are not as expected. [Pg.109]

TSR 15). The data (Tables IV-VI) suggest that this instrument provides a satisfactory method for measuring heat release, even in the horizontal mode. Furthermore, it can differentiate between those materials which are prone to release much heat rapidly and those which perform much better in terms of heat release. The reliability of smoke data is, in principle, lower than that of heat data. In order to establish some criteria, the Tables include SmkFct values at 5 min (in MW/m2), which will be compared with SmkFct and SmkPar values for the same materials tested in the Cone and with values of specific maximum smoke density measured in the NBS smoke chamber. [Pg.527]

An ideal calibration curve (Figure 2.7) is a straight line with a slope of about 45 degrees. It is prepared by making a sequence of measurements on reference materials which have been prepared with known analyte contents. The curve is fundamental to the accuracy of the method. It is thus vitally important that it represents the best fit for the calibration data. Many computer software packages, supplied routinely with various analytical instruments, provide this facility. It is, however, useful to review briefly the principles on which they are based. [Pg.18]

New methods can be created by automatic optimization of parameters during a trial run and all methods can be stored permanently in a non-volatile area of memory which is preserved even when the instrument is switched off. Some instruments provide a means of producing first and second derivatives of the titration curve (p. 243) which can be advantageous where the end-point is indistinct or there is more than one end-point to be detected. Titrators with a substantial amount of RAM incorporate what is in effect a dedicated microcomputer. [Pg.538]

Whereas the role of olfaction in chemical ecology is gaining increased attention, new bioanalytical methodologies and instrumentation provide unprecedented opportunities besides the structural elucidation of pheromones and other chemosignals,... [Pg.20]

Fourier transform infrared instruments provide a more convenient beam geometry—circular rather than slit shaped—at the sample focus. [Pg.31]

This method (EPA 1664) is a liquid-liquid extraction gravimetric procedure that employs n-hexane as the extraction solvent, in place of 1,1,2-trichloroethane (CFC-113) and/or 1,2,2-trifluoroethane (Freon-113), for determination of the conventional pollutant oil and grease. Because the nature and amount of material determined are defined by the solvent and by the details of the method used for extraction, oil and grease method-defined analytes are used. The method may be modified to reduce interferences and take advantage of advances in instrumentation provided that all method equivalency and performance criteria are met. However, n-hexane is a poor solvent for high-molecular-weight petroleum constituents (Speight, 1999, 2001). Thus, the method will produce erroneous data for samples contaminated with heavy oils. [Pg.197]


See other pages where Instrumentation Provided is mentioned: [Pg.1978]    [Pg.464]    [Pg.199]    [Pg.253]    [Pg.214]    [Pg.323]    [Pg.147]    [Pg.537]    [Pg.397]    [Pg.199]    [Pg.216]    [Pg.92]    [Pg.253]    [Pg.169]    [Pg.90]    [Pg.313]    [Pg.539]    [Pg.359]    [Pg.143]    [Pg.21]    [Pg.201]    [Pg.155]    [Pg.261]    [Pg.600]    [Pg.428]    [Pg.211]    [Pg.6]    [Pg.154]    [Pg.308]   