Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analytes characteristics

The comparison of analytical characteristics HPLC methods of determination of phenols with application amperometric and photometric detectors was caiiy out in this work. Experiment was executed with use liquid chromatograph Zvet-Yauza and 100 mm-3mm 150mm-3mm column with Silasorb C18 (5 10 p.m). With amperometric detector phenols were detected in oxidizing regime on glass-cai bon electrodes. With photometric detector phenols were detected at 254 nm. [Pg.129]

Ionic associates (lA) of polyoxometalates (POMs) with threephenylmethane dyes remain as perspective analytical forms for the determination of some nonmetals including P(V), As(V) and Si(IV). Several reasons hinder to the improvement of analytical characteristics of these reactions. Separation of dye excess and its lA with reagent are most important Procedure for extractive separation is often timeconsuming, complex and does not allow complete separation from reagent excess. [Pg.285]

The analytical characteristics of the soi ption-spectroscopic and soi ption-atomic-absoi ption methods developed have been checked up by the analysis of standard solutions, natural, artesian, mineral waters and food salt. [Pg.292]

Biosensors ai e widely used to the detection of hazardous contaminants in foodstuffs, soil and fresh waters. Due to high sensitivity, simple design, low cost and real-time measurement mode biosensors ai e considered as an alternative to conventional analytical techniques, e.g. GC or HPLC. Although the sensitivity and selectivity of contaminant detection is mainly determined by a biological component, i.e. enzyme or antibodies, the biosensor performance can be efficiently controlled by the optimization of its assembly and working conditions. In this report, the prospects to the improvement of pesticide detection with cholinesterase sensors based on modified screen-printed electrodes are summarized. The following opportunities for the controlled improvement of analytical characteristics of anticholinesterase pesticides ai e discussed ... [Pg.295]

In the present work it was studied the dependence of analytical characteristics of the composite SG - polyelectrolyte films obtained by sol-gel technique on the content of non-ionic surfactant in initial sol. Triton X-100 and Tween 20 were examined as surfactants polystyrene sulfonate (PSS), polyvinyl-sulfonic acid (PVSA) or polydimethyl-ammonium chloride (PDMDA) were used as polyelectrolytes. The final films were applied as modificators of glass slides and pyrolytic graphite (PG) electrode surfaces. [Pg.306]

In the present work, the technique of XO and MTB immobilization onto silica gel in the form of its complexes with Fe(III) and Bi(III) respectively were found. The acid - base and chemical-analytical characteristics of solid-phase reagents were examined. The optimal conditions of quantitative recovery of Pb(II) and Zn(II) from diluted solutions, such as acidity of aqueous phase, the mass of the sorbents, the volume of solutions and the time of equilibrium reaching, were found. The methods of and F" detenuination were based on a competitive reactions of Zr(IV) with immobilized MTB and or F". Optimal conditions of 0,0 and F" determination in solution using SG, modified ion associates QAS-MTB (pH = 1,5, = 5-10 mol/1). [Pg.334]

SALI compares fiivorably with other major surface analytical techniques in terms of sensitivity and spatial resolution. Its major advantj e is the combination of analytical versatility, ease of quantification, and sensitivity. Table 1 compares the analytical characteristics of SALI to four major surfiice spectroscopic techniques.These techniques can also be categorized by the chemical information they provide. Both SALI and SIMS (static mode only) can provide molecular fingerprint information via mass spectra that give mass peaks corresponding to structural units of the molecule, while XPS provides only short-range chemical information. XPS and static SIMS are often used to complement each other since XPS chemical speciation information is semiquantitative however, SALI molecular information can potentially be quantified direedy without correlation with another surface spectroscopic technique. AES and Rutherford Backscattering (RBS) provide primarily elemental information, and therefore yield litde structural informadon. The common detection limit refers to the sensitivity for nearly all elements that these techniques enjoy. [Pg.560]

SERS has also been applied as a sensitive, molecule-specific detection method in chromatography, e.g. thin layer, liquid, and gas chromatography. SERS-active colloids were deposited on the thin layer plates or mixed continuously with the liquid mobile phases. After adsorption of the analytes, characteristic spectra of the fractions were obtained and enabled unambiguous identification of very small amounts of substance. [Pg.263]

Successful use of modern liquid chromatography in the clinical laboratory requires an appreciation of the method s analytical characteristics. The quantitative reproducibility with respect to peak height or peak area is quite good. With a sample loop injector relative standard deviations better than 1% are to be expected. The variability of syringe injection (3-4% relative standard deviation) requires the use of an internal standard to reach the 1% level (2,27). [Pg.236]

Strack, D. et al., Cyanidin 3-oxalylglncoside in orchids, J. BioscL, 41, 707, 1986. Choung, M.-G. et al.. Isolation and determination of anthocyanins in seed coats of black soybean (Glycine max (L.) Merr.), J. Agric. Food Chem., 49, 5848, 2001. Covey, T., Analytical characteristics of the electrospray ionization process, in Biochemical and Biotechnological Applications of Electrospray Ionization Mass Spectrometry, ACS Symposium Series, Snyder, A.P. and Anaheim, C. A., Eds., Washington, D.C., 1995, chap. 2. [Pg.504]

In this contribution, we report equilibrium modulus and sol fraction measurements on diepoxidet-monoepoxide-diamine networks and polyoxypropylene triol-diisocyanate networks and a comparison with calculated values. A practically zero (epoxides) or low (polyurethanes) Mooney-Rivlin constant C and a low and accounted for wastage of bonds in elastically inactive cycles are the advantages of the systems. Plots of reduced modulus against the gel fraction have been used, because they have been found to minimize the effect of EIC, incompleteness of the reaction, or possible errors in analytical characteristics (16-20). A full account of the work on epoxy and polyurethane networks including the statistical derivation of various structural parameters will be published separately elsewhere. [Pg.404]

The comprehensive profiling of drug substances and pharmaceutical excipients as to their physical and analytical characteristics remains at the core of pharmaceutical development. As a result, the compilation and publication of comprehensive summaries of physical and chemical data, analytical methods, routes of compound preparation, degradation pathways, uses and applications, etc., has always been a vital function to both academia and industry. [Pg.2]

Solvent polymeric membranes, conventionally prepared from a polymer that is highly plasticized with lipophilic organic esters or ethers, are the scope of the present chapter. Such membranes commonly contain various constituents such as an ionophore (or ion carrier), a highly selective complexing agent, and ionic additives (ion exchangers and lipophilic salts). The variety and chemical versatility of the available membrane components allow one to tune the membrane properties, ensuring the desired analytical characteristics. [Pg.101]

If we try to refine the adequacy between the measurement procedures and the practical needs for wastewater quality monitoring, different metrological (analytical) characteristics have to be considered, such as detection limit, reliability and robustness (Table 3). Even if it is very difficult to compare the analytical methods carried out in the laboratory with on-site measurements (with on-line or tests kits), this presentation points out the main features of the measurement required for different needs. These characteristics define the quality of the available information [3], which constitutes one of the major problems that... [Pg.248]

Table 3 Measurement needs versus analytical characteristics for wastewater monitoring... Table 3 Measurement needs versus analytical characteristics for wastewater monitoring...
Preparation of 4-(l-phenvlethvloxvl-stvrene. This benzylic ether of p-hydroxystyrene was prepared by a Wittig reaction on the precursor aldehyde as described above. The final product was obtained in 73% yield after purification by preparative HPLC using 5% ethyl acetate in hexane as eluent. The product had analytical characteristics in agreement with the proposed structure. [Pg.168]

PROCYANIDINS ANALYTICAL CHARACTERISTICS AND CONCENTRATION IN SIX FRENCH WHITE WINES... [Pg.246]

The impact of the release of liquid products on the environment can, in part, be predicted from knowledge of the properties of the released liquid. Each part of an ocular liquid product from petroleum has its own set of unique analytical characteristics (Speight, 1999, 2002). Since these are well documented, there is no need for repetition here. The decision is to include the properties of the lowest-boiling liquid product (naphtha) and a high-boiling liquid product (fuel oil). For the properties of each product (as determined by analysis) a reasonable estimate can be made of other liquid products, but the relationship may not be linear and is subject to the type of crude oil and the distillation range of the product. [Pg.257]

Despite some distinct advantages of CE for pharmaceutical analysis, the current number of pharmacopoeial monographs which prescribe CE is rather limited. Although it is difficult to point out the exact reason for this, an appropriate training for pharmaceutical analysts in CE-specific analytical characteristics certainly plays an important role. We do hope that this book may provide a contribution in this respect. [Pg.164]

Most residue methods used in field applications are qualitative or semiquantitative and are classified as screening methods. Quantitative methods require much more technical expertise, and, therefore, their primary use is in laboratory applications primarily for confirmation purposes. Both screening and confirmation methods can be subclassified into multiresidue methods aiming at the detection of groups of compounds having similar analytical characteristics, and singleresidue methods applicable to only one specific analyte. [Pg.766]

Table 5 Analytical characteristics of fluoroimmuno-like assays... [Pg.145]


See other pages where Analytes characteristics is mentioned: [Pg.75]    [Pg.90]    [Pg.132]    [Pg.167]    [Pg.456]    [Pg.19]    [Pg.337]    [Pg.338]    [Pg.114]    [Pg.25]    [Pg.237]    [Pg.379]    [Pg.445]    [Pg.569]    [Pg.248]    [Pg.203]    [Pg.75]    [Pg.148]    [Pg.14]    [Pg.1027]    [Pg.59]    [Pg.112]    [Pg.129]    [Pg.155]    [Pg.166]    [Pg.227]    [Pg.227]    [Pg.263]   
See also in sourсe #XX -- [ Pg.314 ]




SEARCH



Analytical characteristics, tandem

Analytical characteristics, tandem mass spectrometry

Analytical method validation characteristics

Analytical methods characteristics

Analytical performance characteristics

Analytical potential energy function characteristics

Analytical procedure validation characteristics

Analytical signal time characteristics

Animal Samples, Characteristics of Sampling Locality and Analytical Methods

Colorants analytical characteristics

Green analytical chemistry characteristics

Iron analytical characteristics

Optimization characteristics analytical

Typical analytical characteristics

© 2024 chempedia.info