SYRINGE

The mixture to be studied is injected by syringe into the head of the column and the molecules comprising the mixture are adsorbed in varying degrees by the stationary phase and desorbed by the liquid phase. At the end of this succession of equilibria, the components of the mixture, more or less separated from each other, leave the column with the solvent. [Pg.26]

The automated pendant drop technique has been used as a film balance to study the surface tension of insoluble monolayers [75] (see Chapter IV). A motor-driven syringe allows changes in drop volume to study surface tension as a function of surface areas as in conventional film balance measurements. This approach is useful for materials available in limited quantities and it can be extended to study monolayers at liquid-liquid interfaces [76],... [Pg.27]

Neumann has adapted the pendant drop experiment (see Section II-7) to measure the surface pressure of insoluble monolayers [70]. By varying the droplet volume with a motor-driven syringe, they measure the surface pressure as a function of area in both expansion and compression. In tests with octadecanol monolayers, they found excellent agreement between axisymmetric drop shape analysis and a conventional film balance. Unlike the Wilhelmy plate and film balance, the pendant drop experiment can be readily adapted to studies in a pressure cell [70]. In studies of the rate dependence of the molecular area at collapse, Neumann and co-workers found more consistent and reproducible results with the actual area at collapse rather than that determined by conventional extrapolation to zero surface pressure [71]. The collapse pressure and shape of the pressure-area isotherm change with the compression rate [72]. [Pg.114]

Figure C3.1.2. Stopped-flow apparatus with motor-driven syringes. Syringe plungers force tire reactants A and B tlirough a mixing chamber into a spectral cell. Kinetic data collection begins when tire effluent syringe plunger is pushed out to contact an activation switch, about a millisecond after tire initiation of mixing. (Adapted from Pilling M J and Seakins P W 1995 Reaction Kinetics (Oxford Oxford University Press)... Figure C3.1.2. Stopped-flow apparatus with motor-driven syringes. Syringe plungers force tire reactants A and B tlirough a mixing chamber into a spectral cell. Kinetic data collection begins when tire effluent syringe plunger is pushed out to contact an activation switch, about a millisecond after tire initiation of mixing. (Adapted from Pilling M J and Seakins P W 1995 Reaction Kinetics (Oxford Oxford University Press)...
Common types of pipets and syringes (a) transfer pipet (b) measuring pipet (c) digital pipet (d) syringe. [Pg.28]

Schematic of a liquid-liquid microextraction showing syringe needle with attached 1-pL droplet. Schematic of a liquid-liquid microextraction showing syringe needle with attached 1-pL droplet.
Solid-phase microextractions also have been developed. In one approach, a fused silica fiber is placed inside a syringe needle. The fiber, which is coated with a thin organic film, such as poly(dimethyl siloxane), is lowered into the sample by depressing a plunger and exposed to the sample for a predetermined time. The fiber is then withdrawn into the needle and transferred to a gas chromatograph for analysis. [Pg.213]

A solid-phase extraction in which the solid adsorbent is coated on a fused-silica fiber held within a syringe needle. [Pg.567]

Samples and calibration standards are prepared for analysis using a 10-mL syringe. Add 10.00 mL of each sample and standard to separate 14-mL screw-cap vials containing 2.00 mL of pentane. Shake vigorously for 1 min to effect the separation. Wait 60 s for the phases to separate. Inject 3.0-pL aliquots of the pentane layer into a GC equipped with a 2-mm internal diameter, 2-m long glass column packed with a stationary phase of 10% squalane on a packing material of 80/100 mesh Chromosorb WAW. Operate the column at 67 °C and a flow rate of 25 mL/min. [Pg.576]

In the load position the sampling loop is isolated from the mobile phase and is open to the atmosphere. A syringe with a capacity several times that of the sampling loop is used to place the sample in the loop. Any extra sample beyond that needed to fill the sample loop exits through the waste line. After loading the sample, the injector is turned to the inject position. In this position the mobile phase is directed through the sampling loop, and the sample is swept onto the column. [Pg.584]

Quantitative Calculations Quantitative analyses are often easier to conduct with HPLC than GC because injections are made with a fixed-volume injection loop instead of a syringe. As a result, variations in the amount of injected sample are minimized, and quantitative measurements can be made using external standards and a normal calibration curve. [Pg.586]

Injector The sample, typically 5-200 )J,L, is placed in the carrier stream by injection. Although syringe injections through a rubber septum are used, a more common means of injection is the rotary, or loop, injector used in ITPLC and shown in Figure 12.28 of Chapter 12. This type of injector provides reproducible injection volumes and is easily adaptable to automation, a feature that is particularly important when high sampling rates are desired. [Pg.652]

For GC, the injector is most frequently a small heated space attached to the start of the column. A sample of the mixture to be analyzed is injected into this space by use of a syringe, which pierces a rubber septum. The injector needs to be hot enough to immediately vaporize the sample, which is then swept onto the head of the column by the mobile gas phase. Generally, the injector is kept at a temperature 50 C higher than is the column oven. Variants on this principle are in use, in particular the split/splitless injector. This injector can be used in a splitless mode, in which the entire injected sample goes onto the column, or in a split mode, in which only part of the sample goes onto the column, the remainder vented to atmosphere. For other less usual forms of injector, a specialist book on GC should be consulted. [Pg.250]


See other pages where SYRINGE is mentioned: [Pg.2390]    [Pg.2949]    [Pg.139]    [Pg.140]    [Pg.140]    [Pg.97]    [Pg.100]    [Pg.572]    [Pg.572]    [Pg.28]    [Pg.193]    [Pg.567]    [Pg.567]    [Pg.567]    [Pg.568]    [Pg.576]    [Pg.634]    [Pg.635]    [Pg.635]    [Pg.778]    [Pg.957]    [Pg.198]    [Pg.411]    [Pg.412]    [Pg.352]    [Pg.404]    [Pg.241]    [Pg.339]    [Pg.509]    [Pg.509]    [Pg.513]    [Pg.421]    [Pg.432]    [Pg.234]    [Pg.176]    [Pg.177]   
See also in sourсe #XX -- [ Pg.163 , Pg.257 ]

See also in sourсe #XX -- [ Pg.27 , Pg.33 , Pg.126 ]

See also in sourсe #XX -- [ Pg.56 ]

See also in sourсe #XX -- [ Pg.423 ]

See also in sourсe #XX -- [ Pg.211 ]

See also in sourсe #XX -- [ Pg.208 ]

See also in sourсe #XX -- [ Pg.211 ]

See also in sourсe #XX -- [ Pg.14 , Pg.15 ]

See also in sourсe #XX -- [ Pg.22 ]

See also in sourсe #XX -- [ Pg.12 , Pg.13 ]

See also in sourсe #XX -- [ Pg.217 ]

See also in sourсe #XX -- [ Pg.85 , Pg.86 , Pg.197 , Pg.198 , Pg.202 , Pg.237 , Pg.318 , Pg.339 , Pg.340 , Pg.344 , Pg.352 , Pg.379 ]




SEARCH



Adhesive, selection syringe dispensing

Advantages and disadvantages of syringe-type pumps

Automatic syringe pump

Basting syringe

Contaminated syringe

Disks syringe disk

Disposable syringe

Dual-chamber syringe delivery system

Equipment syringe pumps

Flow syringe

Fluid delivery systems syringe pumps

Gas syringe

Hamilton syringe

Harvard syringe pump

High-performance liquid chromatography syringe

How to transfer an air-sensitive reagent using a syringe

Injection, sample valve syringe

Insulin syringe

Lab in a syringe

Light syringe

Liquid chromatography syringe

Manual syringe operation

Manual syringe technique

Measuring syringe

Method syringe-reactor

Micro-syringe pumps

Microextraction in a packed syringe

Microextraction in packed syringe

Microliter syringe

Micrometer syringe

Molecular syringe

Motorized syringe methods

Needle sizes, syringe

Oral dosage syringe

Oral syringe

Parenteral suspensions syringeability

Pipet syringe

Powder sampling syringe

Pseudomonas syringe

Pumps syringe

Pumps syringe-type

Rubber syringe plungers

SYRINGE FUZES

Saline syringe

Sample application syringe

Sample application syringe handling

Sample inlets syringe handling

Screw driven syringe

Screw driven syringe pumps

Separation Syringe pump

Septum-type syringe injectors

Solvent delivery systems syringe pumps

Study 1 Pre-Filled Syringe Vials

Supercritical fluid chromatography syringe

Syringate cements

Syringe , process flow, variables

Syringe Systems

Syringe and Needle Application

Syringe application

Syringe barrel

Syringe delivery system

Syringe dispensers

Syringe dispensing

Syringe disposal

Syringe exchange

Syringe exchange schemes

Syringe filters

Syringe handling

Syringe hands, robotic

Syringe infusion system

Syringe injection

Syringe injection precision

Syringe injection, test atmospheres

Syringe injectors

Syringe leakage

Syringe loading

Syringe loading suspension

Syringe membrane filters

Syringe needle

Syringe needles, stainless-steel

Syringe operation

Syringe pipettes

Syringe plunger

Syringe pump Subject

Syringe pump operations

Syringe pump, HPLC

Syringe pumps, double

Syringe pumps, sinusoidal

Syringe readings

Syringe solid-phase microextraction

Syringe techniques

Syringe thin layer chromatography

Syringe, blood collection with

Syringe,contaminated,effect

Syringe-Pump Injection Method

Syringe-based systems

Syringe-type pumps principles

Syringic acid

Syringic acid, oxidation

Syringic aldehyde

Total-volume syringe