Syringe readings

Needle and syringe—purchase die same brand and needle size each time parts of die syringe reading die syringe scale... [Pg.498]

A technique used to overcome this selective evaporation is to draw some pure solvent into the syringe (say 1.5 pi), then about 1 pi of air, about 1 pi of sample, and finally about 1.5 pi of air. The sample slug is then measured in the barrel between the two liquid-air interfaces (two syringe readings). When this is injected, only pure solvent is left in the needle and the amount that evaporates is not important. All of the measured sample volume will be injected. [Pg.205]

C. The 50-unit La-Dose U-100 Insulin Syringe. It is marked up to 50. It makes it easier to read and measure low doses of insulin. [Pg.206]

Determine the titer of the titrant as follows. Tare an empty 50-/rL syringe on an analytical balance, and then fill to the 40-/LL line with distilled water and weigh again. This weight is the weight of the water in the syringe. Press mode on the keypad a few times until the display reads titer with H20 or std. Press enter. ... [Pg.414]

Press Start. Add the measured water to the titration vessel by piercing the septum in the sample inlet port with the needle of the syringe and pushing the plunger all the way in. Remove the syringe from the sample port. Type in the sample weight on the keypad and press enter. The water will now be titrated by the automatic addition of titrant. At the completion of the titration, read and record the titer on the display. [Pg.414]

Figure 1.3. Phase-modulation blood gas instrumentation based on a laser diode light source. Blood gas catheter (lop) direct reading blood gas syringe (bottom). Figure 1.3. Phase-modulation blood gas instrumentation based on a laser diode light source. Blood gas catheter (lop) direct reading blood gas syringe (bottom).
Increasingly there is a need to evaluate simple physical properties such as solvent imbibition in a more rapid manner for high-throughput materials studies, or for real-time evaluation. Recently this issue has been addressed and a very elegant solution developed [75] based on earher work [76, 77]. In this a polypropylene disposable syringe containing a known mass of polymer is suspended from a microbalance and the balance reading set to zero. A reservoir of the solvent to be inves-... [Pg.17]

O.OOl C) the BE-H2O systems were titrated (2.5 ml Gilmont syringe) with DEC until a slight cloudiness appeared, corresponding to the formation of two or more phases. For temperature studies, the temperature of a known mixture of BE-DEC-H2O was varied until a cloud point was observed. The temperature was read to 0.01 C with a pre-calibrated thermistor. In general this technique is fast and quite reproducible but difficulties are often encountered. [Pg.37]

After the run, unload the tube either by puncture of the thin-walled tube with a syringe needle at the bottom, or by displacement by 80% cesium chloride (w/w). For DNA content, read UV absorption of the fractions and refractive index for density calculation (for equations see footnote to Table 5.4). [Pg.178]

Geriatric Considerations - Summary Ensure that the older adult can demonstrate the appropriate use of insulin by assessing his or her ability to draw up the correct dose from a multidose bottle, read syringe markings, and administer the dose subcutaneously. Comorbidities such as poor vision, arthritis, tremor, or cognitive impairment may impair this process. Insulin pens maybe advantageous for some patients. Administration of insulin in the arm results in slower absorption than seen with abdominal administration. [Pg.631]

Prefilled syringes will be monitored for volume check by directly dispensing the content into a tared calibrated cylinder of appropriate capacity, reading the volume, and noting down the weight in the average and range chart. [Pg.832]

A steady pressure should be maintained within the flow cell when performing the detector linearity test. Filling the flow cell with the test solution manually with a syringe sometimes leads to pressure fluctuations and hence unstable readings. An alternative is to use the pump to deliver test solution to the flow cell. However, this option requires a large volume of test solution. [Pg.183]

The use of a 10- yl syringe to deliver a 1-yl volume has a certain error associated with the accuracy to which the syringe markings can be read and the plunger set. This uncertainty alone can contribute 2% to 5% error in a 1-yl volume. [Pg.204]

To tube 2 (3-minute point), add 2.5 mL of the H202 solution, immediately mix, and note the time. Gently and continuously mix the reaction mixture. At the end of exactly 3 minutes, transfer the reaction mixture to the barrel of a syringe with filter system. Force the solution through the filter into a glass cuvette. Read the absorbance of the reaction mixture at 510 nm and record in your notebook. [Pg.394]

Install prepared combustion tube in N2 analyzer. Adjust 45% KOH solution meniscus to calibrating mark in nitrometer with digital readout meter. Record counter reading, / ,. Record syringe temperature, t indicated on special scale thermometer. [Pg.108]

Record new counter reading, R2, and syringe temperature, t2. Determine blank for... [Pg.109]

C. Example Analysis of Active Hydrides or Alkyl Compounds Using a Gas Buret. This procedure utilizes the gas buret illustrated in Fig. 1.19 to analyze active hydrides or alkyls. First, the water levels in the reservoir and buret sides are adjusted to equal height and an initial buret reading is taken. A sample of known weight is introduced into the hydrolysis flask using a syringe. After gas... [Pg.187]


See other pages where Syringe readings is mentioned: [Pg.205]    [Pg.381]    [Pg.329]    [Pg.454]    [Pg.205]    [Pg.381]    [Pg.329]    [Pg.454]    [Pg.111]    [Pg.54]    [Pg.739]    [Pg.256]    [Pg.342]    [Pg.257]    [Pg.219]    [Pg.378]    [Pg.85]    [Pg.231]    [Pg.285]    [Pg.18]    [Pg.172]    [Pg.48]    [Pg.1281]    [Pg.186]    [Pg.204]    [Pg.206]    [Pg.528]    [Pg.394]    [Pg.395]    [Pg.47]    [Pg.111]    [Pg.394]    [Pg.395]    [Pg.3]   
See also in sourсe #XX -- [ Pg.454 ]