Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Microextraction in a packed syringe

MEPS has so far been applied mainly to the analysis of drugs in biological samples only one application for the extraction of PAHs in water has been published.26 One of the major advantages of the MEPS design is that the packed syringe can be used many times over, for example, more than 400 times for water samples. Moreover, the technique permits a fast handling time in the analysis of PAHs in water, the speed enhancement being 15 and 100 times compared to the literature procedures of solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE), respectively see Sections 4.2.3 and 4.2.4. [Pg.73]


MEPS Micro-LLE Microextraction in a packed syringe Micro-liquid-liquid extraction Sample enrichment on a small amount (1-2 mg) of solid material inserted into a syringe (100-250 iL) as a plug. Elution with a suitable solvent As LPME Equally applicable to HPLC and GC analysis... [Pg.322]

MBPS Microextraction in a Packed Syringe RP-HPLC Reverse-Phase HPLC... [Pg.2521]

El-Beqqali, A., A. Kussak, and M. Abdel-Rehim. 2006. Fast and sensitive environmental analysis utilizing microextraction in packed syringe online with gas chromatography-mass spectrometry Determination of polycyclic aromatic hydrocarbons in water. J. Chromatogr. A 1114 234—238. [Pg.91]

Altun, Z., Abdel-Rehim, M., Blomberg, L.G. New trends in sample preparation On-line microextraction in packed syringe (MBPS) for LC and GC applications. Part III Determination and validation of local anaesthetics in human plasma samples using a cation-exchange sorbent and MEPS-LC-MS-MS. J. Chromatogr. B 813, 129-135 (2004)... [Pg.149]

El-Beqqah, A. Kussak, A. Abdel-Rehim, M. Microextraction in packed syringe/hquid chromatography/electrospray tandem mass spectrometry for quantification of acebutolol and meto-prolol in human plasma and urine samples. J. Liq. Chromatogr. Relat. Technol. 2007, 30 (4), 575-586. [Pg.644]

Another recent possibility is to use online sample preparation techniques. Standard SPE cartridges can be used with commercial SPE automation coupled upfront with LC-MS/MS. Alternatively, microextraction by packed sorbent (MEPS) is a miniaturized SPE format intended to work with sample volumes as small as 10 pL. The MEPS sorbent bed is integrated into a syringe that allows for manipulations of low-volume samples, either manually or in... [Pg.24]


See other pages where Microextraction in a packed syringe is mentioned: [Pg.285]    [Pg.73]    [Pg.73]    [Pg.285]    [Pg.73]    [Pg.73]    [Pg.313]    [Pg.87]    [Pg.129]    [Pg.18]    [Pg.123]    [Pg.638]   
See also in sourсe #XX -- [ Pg.285 ]




SEARCH



Microextraction

Microextraction in packed syringe

Microextractions

SYRINGE

© 2024 chempedia.info