Spectrometry induced coupled plasma

Fluorescence (XRF) and Induced Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The results of the analyses are shown in Tables 1 and 2, respectively. [Pg.326]

Induced Coupled Plasma Spectrometry (ICP). An even more sensitive instrument has been developed to detect and quantitate, simultaneously, all inorganic species contained with a sample matrix. One such system is the ICP-OES (optical emission spectrometer) (Figure 25.5). The ICP-OES takes an aliquot of sample that has been acid digested and mixes it with a gas (e.g., argon) forming a plasma (i.e., an ionized gas) that is channeled into a nebulizer. Energy is applied to excite the atoms that are converted by the optics of the instrument into individual wavelengths. The... [Pg.457]

See alsa Air Analysis Outdoor Air. Atomic Emission Spectrometry Microwave-Induced Plasma. Atomic Mass Spectrometry Inductively Coupled Plasma. Elemental Speciation Overview Practicalities and Instrumentation. Gas Chromatography Environmental Applications. Isotope Dilution Analysis. Isotope Ratio Measurements. [Pg.2471]

See also Activation Anaiysis Neutron Activation Charged-Particle Activation Photon Activation. Atomic Emission Spectrometry Inductively Coupled Plasma. Atomic Mass Spectrometry Inductively Coupled Plasma. Mass Spectrometry Overview. Surface Analysis Particle-Induced X-Ray Emission Auger Electron Spectroscopy Ion Scattering Nuclear Reaction Analysis and Elastic Recoil Detection. X-Ray Fluorescence and Emission Wavelength Dispersive X-Ray Fluorescence Energy Dispersive X-Ray Fluorescence. [Pg.4568]

See also Atomic Absorption Spectrometry Interferences and Background Correction. Atomic Emission Spectrometry Principles and Instrumentation Interferences and Background Correction Flame Photometry Inductively Coupled Plasma Microwave-Induced Plasma. Atomic Mass Spectrometry Inductively Coupled Plasma Laser Microprobe. Countercurrent Chromatography Solvent Extraction with a Helical Column. Derivatization of Analytes. Elemental Speciation Overview Practicalities and Instrumentation. Extraction Solvent Extraction Principles Solvent Extraction Multistage Countercurrent Distribution Microwave-Assisted Solvent Extraction Pressurized Fluid Extraction Solid-Phase Extraction Solid-Phase Microextraction. Gas Chromatography Ovenriew. Isotope Dilution Analysis. Liquid Chromatography Ovenriew. [Pg.4847]

Wcssman reviewed a number of instruments used for uranium analyses and ranked their relative measurement sensitivities [32]. The methods include atomic absorption spectrophotometry, colorimetry, neutron bombardment, fission etched track detectors, fluorimetry, laser-induced fluorescence spectrometry, a-spectrometry, isotope dilution mass spectrometry, and spark source mass spectrometry. The majority of urinary bioassay measurements have been performed by fluorimetry, while environmental survey and baseline measurements have been performed by fluorimetry, a-spectrometry, and induced coupled plasma source mass spectrometry. [Pg.647]

Guillong M, Gunther D (2002) Effect of particle size distribution on ICP-induced elemental fractionation in laser ablation-inductively coupled plasma-mass spectrometry. J Anal At Spectrom 7 831-837 Gunther D (2002) Laser-ablation inductively coupled plasma mass spectrometry. Anal Bioanal Chem 372 31-32... [Pg.56]

This presentation will summarize developments in laser ablation with emphasis on LIBS (laser induced breakdown spectroscopy) and inductively coupled plasma mass spectrometry (ICPMS) as analytical tools for real time chemical analysis (Fig. 1) (Russo et al. [Pg.295]

Cremers, D.A. Radziemski, L.J. 2006. Handbook of Laser Induced Breakdown Spectroscop. J. Wiley Sons, New York Gonzalez, J., Oropeza, D., Mao, X.L., Russo, R.E. 2008. Assessment of the precision and accuracy of thorium (232Th) and uranium (238U) measured by quadrupole based-inductively coupled plasma-mass spectrometry comparison of liquid... [Pg.298]

Jackson SE, Gunther D (2003) The nature and sources of laser induced isotopic fractionation in laser ablation-multicollector-inductively coupled plasma-mass spectrometry. J Anal At Spectrom 18 205-212 Jiang S-J, Houk RS, Stevens MA (1988) Alleviation of overlap interferences for determination of potassium isotope ratios by Inductively-Coupled Plasma Mass Spectrometry. Anal Chem 60 1217-1220 Lam JWH, Horlick G (1990) A comparison of argon and mixed gas plasmas for inductively coupled plasma-mass spectrometry. Spectrochim Acta Part B 45 1313-1325 Langmuir I, Kingdon KH(1925) Thermionic effects caused by vapours of alkali metals. Phil Trans R Soc A107 61-79... [Pg.148]

CONTENTS Preface, Joseph Sneddon. Analyte Excitation Mechanisms in the Inductively Coupled Plasma, Kuang-Pang Li and J.D. Winefordner. Laser-Induced Ionization Spectrometry, Robert B. Green and Michael D. Seltzer. Sample Introduction in Atomic Spectroscopy, Joseph Sneddon. Background Correction Techniques in Atomic Absorption Spectrometry, G. Delude. Flow Injection Techniques for Atomic Spectrometry, Julian F. Tyson. [Pg.268]

Other frequently used methods for determining fluoride include ion and gas chromatography [150,204,205] and aluminium monofluoride (AIF) molecular absorption spectrometry [206,207]. Less frequently employed methods include enzymatic [208], catalytic [209], polarographic [210] and voltammetric methods [211], helium microwave-induced [212] or inductively coupled plasma atomic emission spectrometry [213], electrothermal atomic absorption spectrometry [214], inductively coupled plasma-mass spectrometry [215], radioactivation [216], proton-induced gamma emission [217], near-infrared spectroscopy [218] and neutron activation analysis [219]. [Pg.534]

Until now, little attention has been given to the analysis of ancient copper alloys with LA-ICP-MS. This type of material is usually analyzed with fast or instrumental neutron activation analysis (FNAA or INAA), particle induced X-ray emission (PIXE), X-ray fluorescence (XRF), inductively coupled plasma-atomic emission spectrometry or inductively coupled plasma-atomic absorption spectrometry (ICP-AES or ICP-AAS). Some of these techniques are destructive and involve extensive sample preparation, some measure only surface compositions, and some require access to a cyclotron or a reactor. LA-ICP-MS is riot affected by any of these inconveniences. We propose here an analytical protocol for copper alloys using LA-ICP-MS and present its application to the study of Matisse bronze sculptures. [Pg.337]

Since the mid-1960s, a variety of analytical chemistry techniques have been used to characterize obsidian sources and artifacts for provenance research (4, 32-36). The most common of these methods include optical emission spectroscopy (OES), atomic absorption spectroscopy (AAS), particle-induced X-ray emission spectroscopy (PIXE), inductively coupled plasma-mass spectrometry (ICP-MS), laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS), X-ray fluorescence spectroscopy (XRF), and neutron activation analysis (NAA). When selecting a method of analysis for obsidian, one must consider accuracy, precision, cost, promptness of results, existence of comparative data, and availability. Most of the above-mentioned techniques are capable of determining a number of elements, but some of the methods are more labor-intensive, more destructive, and less precise than others. The two methods with the longest and most successful histoty of success for obsidian provenance research are XRF and NAA. [Pg.527]

Figure 6.1 Bar-graph of MeHg in CRM 580. The results correspond to six replicate determinations as performed by different laboratories using various methods. MEANS indicates the mean of laboratory means with 95% confidence interval. Abbreviations-. CVAAS, cold vapour atomic absorption spectrometry CVAFS, cold vapour atomic fluorescence spectrometry ECD, electron capture detection GC, gas chromatography HPLC, high-performance liquid chromatography ICPMS, inductively coupled plasma mass spectrometry MIP, microwave induced plasma atomic emission spectrometry QFAAS, quartz furnace atomic absorption spectrometry SFE, supercritical fluid extraction. Figure 6.1 Bar-graph of MeHg in CRM 580. The results correspond to six replicate determinations as performed by different laboratories using various methods. MEANS indicates the mean of laboratory means with 95% confidence interval. Abbreviations-. CVAAS, cold vapour atomic absorption spectrometry CVAFS, cold vapour atomic fluorescence spectrometry ECD, electron capture detection GC, gas chromatography HPLC, high-performance liquid chromatography ICPMS, inductively coupled plasma mass spectrometry MIP, microwave induced plasma atomic emission spectrometry QFAAS, quartz furnace atomic absorption spectrometry SFE, supercritical fluid extraction.
Gholap D, Izmer A, Samber B, van Elteren J, Selih V, Evens R, Schamphelaere K, Janssen C, Balcaen L, Lindemann I, Vincze L, Vanhaecke F (2010) Comparison of laser ablation-induc-tively coupled plasma-mass spectrometry and micro-X-ray fluorescence spectrometry for elemental imaging. Anal Chim Acta 664 19-26. doi 10.1016/j.aca.2010.01.052... [Pg.419]

ICP-AES=inductively coupled plasma-atomic emission spectrometry Mg(N03)3=magnesium nitrate MIBK=methylisobutyl ketone MS=mass spectrometry PIXE=proton-induced X-ray emission spectrometry XRF=X-ray fluorescence analysis WM-AES=wavelength-modulated atomic emission spectrometry... [Pg.372]

The most suitable techniques for the rapid, accurate determination of the elemental content of foods are based on analytical atomic spectrometry, for example, atomic absorption spectrometry (AAS), atomic emission spectrometry (AES), and mass spectrometry, the most popular modes of which are Game (F), electrothermal atomization (ET), and hydride generation (HG) AAS, inductively coupled plasma (ICP), microwave-induced plasma (MIP), direct current plasma (DCP) AES, and ICP-MS. Challenges in the determination of elements in food include a wide range of concentrations, ranging from ng/g to percent levels, in an almost endless combination of analytes with matrix speci be matrices. [Pg.20]

R. M. Munoz Olivas, O. F. X. Donard, N. Gilon, M. Potin-Gautier, Speciation of organic selenium compounds by high-performance liquid chromatography-induc-tively coupled plasma mass spectrometry in natural samples, J. Anal. Atom. Spectrom., 11 (1996), 1171-1176. [Pg.668]

Meeravali, N.N., Kumar, S.J., Jiang, S.J. An acid induced mixed-micelle mediated cloud point extraction for the separation and pre-concentration of platinum from road dust and determination by inductively coupled plasma mass spectrometry. Anal. Methods 2, 1101-1105 (2010)... [Pg.401]

As noted earlier, USNs have been employed for sample insertion into atomic spectrometers suoh as flame atomio absorption spectrometry (FAAS) [9,10], electrothermal atomic absorption speotrometry (ETAAS) [11], atomic fluorescence spectrometry (AFS) [12,13], induotively ooupled plasma-atomic emission spectrometry (ICP-AES) [14,15], inductively coupled plasma-mass spectrometry (ICP-MS) [16,17] and microwave induced plasma-atomic emission spectrometry (MIP-AES) [18,19]. Most of the applications of ultrasonic nebulization (USNn) involve plasma-based detectors, the high sensitivity, selectivity, precision, resolution and throughput have fostered their implementation in routine laboratories despite their high cost [4]. [Pg.256]

Direct nebulization of an aqueous or organic phase containing extracted analytes has been widely used in flame atomic absorption spectroscopy [69-72], inductively coupled plasma atomic emission spectrometry [73-76], microwave induced plasma atomic emission spectrometry [77-80] and atomic fluorescence spectrometry [81], as well as to interface a separation step to a spectrometric detection [82-85]. [Pg.62]

XRD, X-ray diffraction XRF, X-ray fluorescence AAS, atomic absorption spectrometry ICP-AES, inductively coupled plasma-atomic emission spectrometry ICP-MS, Inductively coupled plasma/mass spectroscopy IC, ion chromatography EPMA, electron probe microanalysis SEM, scanning electron microscope ESEM, environmental scanning electron microscope HRTEM, high-resolution transmission electron microscopy LAMMA, laser microprobe mass analysis XPS, X-ray photo-electron spectroscopy RLMP, Raman laser microprobe analysis SHRIMP, sensitive high resolution ion microprobe. PIXE, proton-induced X-ray emission FTIR, Fourier transform infrared. [Pg.411]


See other pages where Spectrometry induced coupled plasma is mentioned: [Pg.208]    [Pg.457]    [Pg.444]    [Pg.825]    [Pg.7]    [Pg.261]    [Pg.295]    [Pg.426]    [Pg.140]    [Pg.84]    [Pg.20]    [Pg.95]    [Pg.68]    [Pg.430]    [Pg.379]    [Pg.381]    [Pg.409]    [Pg.275]    [Pg.257]   
See also in sourсe #XX -- [ Pg.457 ]