The wavelengths of the emission lines are characteristic of the elements present in the plasma source. The detection of radiation at particular wavelengths can be applied to the qualitative analysis of the sample and the intensities measured at these wavelengths to the quantitative analysis of the analyte elements. [Pg.154]

Most analytical plasma sources are electrical gas discharges at atmospheric pressure, usually in argon or in another inert gas. The various plasmas look like flames, but their temperatures are significantly higher—normally more than 5000 K in the viewing zone. [Pg.154]

The analysis of liquids is rather difficult using classical spectroscopic sources [i.e. arcs and sparks), but various plasma sources permit the direct and easy analysis of liquids. [Pg.154]


Plasma atomic emission spectrometry is also employed as a detection method for gc (see Plasma technology). By monitoring selected emission lines a kind of selective detection based on elemental composition can be achieved (see Spectroscopy). [Pg.108]

P. W. J. M. Boumans. Line Coincidence Tables for Inductively Coupled Plasma Atomic Emission Spectrometry. Pergamon Press, Oxford, 1980, 1984. Lists of emission lines for analysis and potentially overlapping lines with relative intensities, using spectrometers with two different resolutions. [Pg.644]

Aluminium, boron, silicon Inductively coupled plasma atomic emission spectrometry ... [Pg.318]

Minganti V, Capelli R, Depellegrini R (1995) Evaluation of different derivatization methods for the multielement detection of Hg, Pb and Sn compounds by gas chromatography-microwave induced plasma-atomic emission spectrometry in environmental samples. Fresenius Journal of Analytical Chemistry, 351 (4-5) 471 77. [Pg.48]

Pt content determined by inductively coupled plasma-atomic emission spectrometry (ICP-AES). Monolayer uptakes (P = 0) determined at 295 K. [Pg.157]

Moens L, Verreft P, Boonen S, Vanhaecke F and Dams R (1995) Solid sampling electrothermal vaporization for sample introduction in inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry. Spectrochim Acta 508 463-475. Mooijman KA, In t Veld PH, Hoekstra JA, Heisterkamp SH, Havelaar AH, Notermans SHW, Roberts D, Griepink B, Maier E (1992) Development of Microbiological Reference Materials. European Commission Report EUR 14375 EN, Community Bureau of Reference, Brussels. [Pg.46]

ScHiFFER U, Krivan V (i999) A graphite furnace electrothermal vaporization system for inductively coupled plasma atomic emission spectrometry. Anal Chem 70 482-490. [Pg.47]

Verrept P, Dams R, Kurfurst U 1993) Electrothermal vaporisation inductively coupled plasma atomic emission spectrometry for the analysis of solid samples contribution to instrumentation and methodology. Fresenius 2 Anal Chem 345 1035-1041. [Pg.153]

Magnesium deficiency has been long recognized, but hypermagnesia also occurs (Anderson and Talcott 1994). Magnesium can be determined in fluids by FAAS, inductively coupled plasma atomic emission spectrometry (ICP-AES) and ICP-MS. In tissue Mg can be determined directly by solid sampling atomic absorption spectrometry (SS-AAS) (Herber 1994a). Both Ca and Mg in plasma/serum are routinely determined by photometry in automated analyzers. [Pg.202]

Method abbreviations D-AT-FAAS (derivative flame AAS with atom trapping), ETAAS (electrothermal AAS), GC (gas chromatography), HGAAS (hydride generation AAS), HR-ICP-MS (high resolution inductively coupled plasma mass spectrometry), ICP-AES (inductively coupled plasma atomic emission spectrometry), ICP-MS (inductively coupled plasma mass spectrometry), TXRF (total reflection X-ray fluorescence spectrometry), Q-ICP-MS (quadrapole inductively coupled plasma mass spectrometry)... [Pg.219]

Inductively Coupled Plasma-Atomic Emission Spectrometry... [Pg.619]

ASTM. 1998a. ASTME1613. Standard test method for analysis of digested samples for lead by inductively coupled plasma atomic emission spectrometry (ICP-AES). Flame Atomic Absorption (FAAS), or Graphite Furnace Atomic Absorption (GFAA) Techniques. American Society for Testing and Materials. [Pg.488]

Inductively coupled plasma atomic emission spectrometry (ICP-AES) is used to screen polymers, liquids and solvent extracts for residual metal atoms (catalysts, fillers, etc.). The technique can provide rapid multi-component screening of elements in solution over a wide concentration range (0.1-1,000 pg/ml). [Pg.571]

Methylated organo-selenium has been determined by GC/MS or fluorine-induced chemiluminescence to determine DMSe, DMDSe, and DMSeS. This last compound, dimethyl selenenyl sulfide, was mistakenly identified as dimethyl selenone (CH3Se02CH3) in earlier work with bacteria.181,182 However, much recent work with many microorganisms have shown ample evidence of DMSeS production from Gram-negative bacteria,181,183 phototrophic bacteria,167,184 phytoplankton185 and in B. juncea detailed above. SPME with microwave-induce plasma atomic emission spectrometry was recently used to... [Pg.701]

Measurement techniques that can be employed for the determination of trace metals include atomic absorption spectrometry, anodic stripping voltammetry, differential pulse cathodic stripping voltammetry, inductively coupled plasma atomic emission spectrometry, liquid chromatography of the metal chelates with ultraviolet-visible absorption and, more recently, inductively coupled plasma mass spectrometry. [Pg.128]

Brenner et al. [ 169] applied inductively coupled plasma atomic emission spectrometry to the determination of calcium (and sulfate) in brines. The principal advantage of the technique was that it avoided tedious matrix matching of calibration standards when sulfate was determined indirectly by flame techniques. It also avoided time-consuming sample handling when the samples were processed by the gravimetric method. The detection limit was 70 ig/l and a linear dynamic range of 1 g/1 was obtained for sulfate. [Pg.156]

Heavy Metals, Isotope Dilution, Spark Source Mass Spectrometry, and Inductively Coupled Plasma Atomic Emission Spectrometry... [Pg.335]

Silicon has been determined directly in seawater by inductively coupled plasma atomic emission spectrometry with a detection limit of 0.3 xm silicon [42],... [Pg.484]

Organogermanium compounds can be mineralized by wet oxidative digestion for 4 h at 70°C, in aqueous potassium persulphate, at pH 12. After dilution to an adequate concentration germanium can be determined by ICP-AES (inductively coupled plasma atomic emission spectrometry)9. [Pg.344]

Prior to analysis, solutions from seven-day T/D tests on cuprous oxide (Cu20) and nickel metal powder (Ni) were passed through a column with iminodiacetate functional groups using an ammonium acetate buffer. The alkali and alkali earth metals are not bound to the column thereby separating the cations associated with the saltwater matrix from the transition metals of interest which are subsequently eluted with nitric acid and analysed by ICP-AES (inductively-coupled plasma-atomic emission spectrometry). [Pg.100]

Owing to their superior fluorescent yield, heavy elements ordinarily yield considerably more intense XRF bands than the light elements. This feature can be exploited to determine the concentration of inorganic species in a sample, or the concentration of a compound that contains a heavy element in some matrix. Many potential XRF applications have never been developed owing to the rise of atomic spectroscopic methods, particularly inductively coupled plasma atomic emission spectrometry [74]. Nevertheless, under the right set of circumstances, XRF analysis can be profitably employed. [Pg.225]