Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Operator s intervention

In bioanalysis, extracted samples are usually stored in either autosampler vials or wells in a plate (such as 96-well plate) sealed with pierceable caps or covers. During injection, the autosampler needle has to pierce the caps or covers to load samples. The debris may completely or partially block the autosampler needle, which would result in no sample or variably low sample volumes injected. Accordingly, no or randomly low IS responses are observed. As most autosamplers have a built-in needle flushing mechanism, the debris in the needle might be flushed out later partially or completely. Therefore, the injected volume can be back to normal at a later time without an operator s intervention. Apparently, when a needle will be blocked and when the blocked needle will be cleared by flushing, as well as how it will be blocked (completely or partially) are difficult to predict. Hence, there would be no clear pattern for this type of IS variations. However, the affected injections normally have lowered IS responses (Fig. 9). Despite lowered IS responses, the accuracy of quantitation can usually be maintained except for situations where no or very low amount of samples are injected, resulting in responses outside the limit of linear range or unacceptable S/N. [Pg.17]

As soon as the mold has been opened, the article can be removed at the parting plane. In the simplest cases, this can be performed manually. However, the injection molding process is designed specifically for mass-producing articles at a fast rate and should ideally operate in fully automatic mode. It is therefore obvious, that manual removal takes too much time. Furthermore, the cycle time fluctuates as a result of the operator s intervention in the machine cycle. This can cause variations in the molding s quality. With thermoplastics, manual removal is used only in exceptional cases, where articles are dehcate or of complex shape. [Pg.51]

The versatility of the design of an analytical pervaporation module, attributable to its changeable donor volume and the air gap present above the sample, has enabled its use with liquid, solid, and semisolid samples. Table 1 summarizes the applications of analytical pervaporation and the main fields in which it has been used. The manifold used and the way in which the sample is introduced in the system vary depending on whether it is liquid or solid. The main difference between the treatment of liquid and solid samples is the fact that with liquids the whole pervaporation process, from sample introduction to delivery of the results can be fully automated, while some operator s intervention is needed when dealing with solids. [Pg.3000]

A low interface level (LIE) is usually used to raise an alarm for the operator s intervention. The required distance and liquid residence time between LIE and LILSD depends on the fluctuation of the incoming liquid and the possible liquid withdrawal rate. Eor a relatively steady flow, a 150 mm gap between LIE and LILSD is often used, with a liquid residence time ranging from 1 to 3 min. A low liquid level (LLL) can also be set for a 1 to 3 min residence time. Like LLLSD, LLL can also be set either above or below the weir level, depending on the application. [Pg.220]

Media fill operation shall be monitored for the operator s behavior (the usual and unusual intervention) through fixed cameras. [Pg.873]

Automation In data acquisition and treatment can be aimed at a variety of objectives inherent in the above-mentioned factors. It should be pointed out that physical and physico-chemical kinetic factors play a decisive role in the reduction of human Intervention. The acquisition of data at a high rate imposed by the technique Itself (e.g. picosecond spectroscopy [19]) or by the system Investigated (e.g. meaurements of rates of reactions with half-lives of the order of a few milliseconds by the stopped-flow methodology [20,21]) demand the use of a computerized system without which application of the particular spectroscopic technique or method would not be feasible. On the other hand, the so-called microprocessor-controlled spectroscopy , widely commercialized at present, broadens the scope and facilitates the operator s work by eliminating various sources of error. [Pg.288]

Actions resulting from human error are usually handled by direct intervention, rather than waiting for automatic correction. In most cases, where plant instabilities are not causing the reactor to trip, the operator s knowledge and experience will enable him to retrieve the position and bring the plant back to the stable condition. At no time is the Central Control Room manned by less than three persons when two reactors are operating. [Pg.67]

Consequently, you ll want to closely track your operation s results in this area. But more than simply tracking your result, you will also want to gather as much information as possible about each driver turnover event. What happened What were the issues Could the driver have been saved What intervention steps were taken to try and save the relationship Is the driver eligible for rehire Getting answers to questions like these will help you better understand your driver turnover problem, and get closer to solutions. [Pg.742]

In modelling ATWS accidents, it is essential to determine the critical points in time for intervention, i.e. when the recovered shutdown function is able to reduce the consequences to an acceptable level. It is necessary to determine the time when FPR and emergency protection signals are generated and when the set points are reached for warning signals to appear at the operator s console. [Pg.54]

The plutonium canister assay system (PCAS) determines the content of plutonium in MOX and pure oxide powders in cans contained in a specific transport container (four cans per canister) (Menlove et al. 1986). The system can be integrated into an operator s material handling system and continuous measurement cycles are performed, which are evaluated at the end of a given collection period. Thereby, continuous verification of the flow of canisters can be performed without inspectorate intervention. For inventory verification, an inspector provides an electronic list of canisters to be verified and the operator transfers the selected... [Pg.2931]

The spinal cord is the organizer of information, which is processed from the brain to other regions. Feedback from these areas to the brain helps maintain normal function. A difficult concept to grasp is that parts of the body may communicate directly with one another without the brain s intervention. In these communications, the nervous system is less like a two-way intercom system in a large apartment house than like a fully interactive telephone system with the brain acting as the operator. A common example... [Pg.38]

As for the retailers, it can be easily verified that the manufacturer s intervention will lower their expected profits. However, the manufacturer s intervention will never reduce the retailers expected profits to a level lower than in the absence of the secondary market. At the same time, since the service level to the primary-market customers is only a function of the order quantity 2, it is clear from Theorem 5 that the manufacturer s intervention will always reduce the service level to this segment of the market, even though diese customers will still be better off compared to the situation where the secondary maiket does not operate at all. Finally, the secondary market customers will always benefit from the manufacturer s intervention, as summarized in Theorem 6 ... [Pg.157]

The precursor was identified in the maintenance sub-process. In practice, the operators from technical support observed the presence of substances inside the packaging machines. Subsequently, they consulted the chief operator on how to remove the substances from the machines and perform the most suitable intervention. These actions correspond with the control elements on the operational control level. The actions were performed in order to resume production quickly, and adhere to planned schedules. Additionally, experience and training provided the operators with guidelines on how to perform the maintenance effectively. In practice the production manager, responsible for any preventive solutions was not aware of the existence of this precursor and consequently had no overview of these deviations even though the company s quality and safety standards required an overview of all deviations and... [Pg.100]

Louis Pasteur (1822-1895) established that some diseases are caused by microorganisms and not, as was thought to be the case at the time, by miasmas, evil spirits or divine intervention. Despite the scepticism of physicians, as illustrated above, Pasteur s work inspired a British surgeon, Joseph Lister, to introduce antiseptic methods into surgery in order to prevent wound infection. In March 1865, he operated for the first time using an antiseptic, carbolic acid (phenol). There were no infections after the surgery - a rare occurrence at that time. [Pg.375]

In 2005, a continued decline in methamphetamine abuse (methamphetamine pills or yaba ) was reported by Thailand. This followed a forceful intervention by the Thai authorities in the market in 2003, which resulted in a decline in methamphetamine abuse, but unfortunately also in a significant number of casualties. The 2001 household survey showed that Thailand had a prevalence rate of 2.4 per cent of the population aged 12-65 and thus the world s most serious methamphetamine problem at the time, despite also having reported the world s largest ATS seizures for many years. In 2003, a subsequent household survey found far lower prevalence rates (0.2 per cent)8. However, these data may have been influenced by police operations, resulting in a likely underestimate as respondents were influenced by... [Pg.155]

Labor and operating costs are low. The system is highly automated allowing for minimal operator intervention. The two major operating costs are power and membrane maintenance. Allied-Signal s commitment and continued research and development of the AQUATECH membranes and stack design ensures longer lifetime on the membrane and even more power efficient units. Membrane replacements are facilitated by cell modules pre-assembled for easy installation. [Pg.286]

In the new designs, if coolant were lost, the nuclear chain reaction would be terminated by the reactor s negative temperature coefficient after a modest temperature rise. Core diameter of the modular units would be limited so that decay heat could be conducted and radiated to the environment without overheating the fuel to the point where fission products might escape. Thus, inherent safety would be realized without operator or mechanical device intervention. [Pg.1111]


See other pages where Operator s intervention is mentioned: [Pg.9]    [Pg.18]    [Pg.667]    [Pg.126]    [Pg.9]    [Pg.18]    [Pg.667]    [Pg.126]    [Pg.64]    [Pg.23]    [Pg.20]    [Pg.389]    [Pg.222]    [Pg.166]    [Pg.1624]    [Pg.1321]    [Pg.193]    [Pg.227]    [Pg.49]    [Pg.1187]    [Pg.310]    [Pg.140]    [Pg.4]    [Pg.115]    [Pg.180]    [Pg.46]    [Pg.367]    [Pg.99]    [Pg.156]    [Pg.212]    [Pg.123]    [Pg.47]    [Pg.291]    [Pg.44]    [Pg.733]    [Pg.172]    [Pg.476]   
See also in sourсe #XX -- [ Pg.220 ]




SEARCH



S operators

© 2024 chempedia.info