Operator intervention

FIG. 21-39 Microprocessor-controlled drum and pail filling and weighing machine. Will fill drums or pads on one tier without operator intervention. Couiiesy ofK Systems, Inc., Bloomfield, NJ.)... [Pg.1954]

Alarms should require an operator intervention otherwise they should not be classified as alarms... [Pg.123]

It is reasonable to assume there would be no operator intervention in time to prevent a 100°F rise in expander inlet temperature. Line G represents the power delivered to the generator at the higher temperature of 1,300°F. Either the operators or a eontroller will likely add a water spray to prevent a further rise in temperature. [Pg.169]

Error recovery by the operators is only one of several layers of protection to prevent undesired consequences (see Figure 2.1). Process and equipment designs (discussed in previous chapters) that prevent undesired process excursions are inherently safer than designs that require operator intervention. Likewise, designs that enable the operators to intervene before an upset becomes serious are inherently safer than those that do not. [Pg.112]

Process control instrumentation controls the FCC unit in a safe, monitored mode with limited operator intervention. Two levels of process control are used ... [Pg.177]

PCs all have one thing in common. They monitor the process variables, compare them to values known to be acceptable, and make appropriate corrections without operator intervention. The acceptable range of values can be determined by using melt flow analysis software and/or trial and error when the machine is first starting its production. Using the software approach, the acceptable process values are known before the mold or die is ever built. It should be noted that none of the PC solutions address the problem of the lack of skilled setup people. Most of the PC systems available today are rather complex and require skilled people to use them efficiently or at least start up the line. [Pg.531]

In the vast majority of GC-MS applications, the chromatographic conditions employed have little or no effect on the operation of the mass spectrometer. This means that the spectrometer may be tuned for optimum performance and a number of samples containing different analytes can be analysed without operator intervention. This is not the case with LC-MS where the chromatographic conditions will invariably have a significant, compound-dependent, effect on the mass spectrometry conditions required to obtain useful analytical data. [Pg.188]

In addition, each workbook contained a summary table of all results and limit of detection (LOD) determinations. The table was organized with sample identifications in the left-hand column. Eor each analyte, the analytical result and the LOD appeared in adjacent columns, and analyte recoveries appeared above the results columns. The summary table was generated automatically from the analytical results in the individual worksheets, without operator intervention or re-entry of any information. [Pg.244]

Mitigating events or mitigating factors act to impede the accident sequence, resulting in less severe consequences. Examples include detection and activation of emergency shutdown systems, operator intervention, spill containment, equipment spacing, natural dispersion, and reducing the... [Pg.87]

The data structures and the control flow through the data handling activities are depicted in Figure 3. We use a batch approach to data collection so that the instrument can perform a series of data acquisition tasks without requiring operator intervention. A batch of tasks may take several days when diffraction is weak or when there are interferences. The structure of the data handling activities is governed by the batch nature of the data collection process. [Pg.143]

Nevertheless, the acquisition of a sufficiently detailed body of physical information can allow a formulator to go far beyond the mere ability to cope with crises when they develop at unexpected times. For a well-understood system, it is theoretically possible to design an automated or semi-automated manufacturing scheme for which the processing variables would be appropriately controlled so as to minimize the possibility of batch failure. Materials passing the hurdles of physical test specifications would be totally predictable in their performance, and they could therefore be blended, granulated, dried, compressed, and delivered into containers without operator intervention. [Pg.3]

These results do not have any diagnostic meaning. The dynamics of the ACU values after an operative intervention could be taken into account regarding the existence of metastases. As demonstrated in Figure 12, prognostic relevance can be ascribed to ACU. The rise in ACU value is caused in this case by increase of the bilirubin level under the conditions of the life-threatening inflammatory processes [1],... [Pg.513]

A variety of online solid extraction devices and applications have been developed for bioanalysis. Many are easy to build in laboratories or commercially available. Unlike offline methods, minimal operator intervention is needed for daily sample analysis after online applications are set up, so the approach is both labor- and cost-effective. The technique can also minimize errors arising from manual operations, eliminate potential inconsistencies caused by different operators, and provide accessibility of LC/MS/MS applications to laboratories that have minimal analytical expertise. [Pg.280]

Research and development technologists at the Dow Chemical Company can characterize materials in a variety of ways. One material property that is especially critical in polymer foaming and processing technology is density. A tool used for measuring the density of a material is called a pycnometer. There are many different manual and automatic types to choose from. For extremely accurate and precise density measurements, an easy-to-use, fully automatic gas displacement pycnometer is utilized. Analyses are commenced with a single keystroke. Once an analysis is initiated, data are collected, calculations performed, and results displayed without further operator intervention. [Pg.435]

Filters are sometimes derived from test cargo calibration runs to optimize the explosive detection. The PFNA detection algorithm can be totally automated but previous demonstrations (prior to the 2005 Ysleta Port of Entry testing) have used operator intervention to evaluate the basic scan alarm regions before a directed scan is made of the selected basic scan alarm regions. [Pg.80]

The third stage is data transmission during which the microcomputer transmits the entire data set for the sample to the minicomputer. The data is stored on disk until the operator initiates the fourth stage, data reduction. If multiple samples and injections have been programmed, the minicomputer sends to the microcomputer the information in the sample definition file for the next sample, and operation continues without further operator intervention. [Pg.62]

For the purposes of presentation, the velocity held is usually presented at regular intervals. This new scheme is very efficient and incorporates a vector validation procedure, making it independent of operator intervention. The time it takes to compute a vector field depends on the computer hardware and it ranges from 350 mesh points per second on a PC 150 MHz Pentium to 1400 mesh points per second on a 200-megahertz dual Pro. [Pg.289]

The system is used for the isolation of multimilligrams to grams of impurities, intermediates, and reference materials. A high degree of automation enables operation with minimum operator intervention and recoveries of >80% with... [Pg.220]

Lidocaine is the most widely used local anesthetic. Its excellent therapeutic activity is fast-acting and lasts sufficiently long to make it suitable for practically any clinical use. It stabilizes cell membranes, blocks sodium channels, facilitates the secretion of potassium ions out of the cell, and speeds up the repolarization process in the cell membrane. It is used for terminal infiltration, block, epidural, and spinal anesthesia during operational interventions in dentistry, otolaryngology, obstetrics, and gynecology. It is also used for premature ventricular extrasystole and tachycardia, especially in the acute phase of cardiac infarction. Synonyms for this drug are xylocaine, neflurane, and many others. [Pg.15]

Chlordiazepoxide is used for treating neurotic conditions such as reheving feelings of fear, worry, and stress. It exhibits soporific action on the CNS, causes muscle relaxation, and possesses anticonvulsant activity. It is frequently used after operational interventions. The most frequently used synonyms are elenium and hbrium. [Pg.74]

Operator intervention A manual shutdown can be activated by an operator if the potential exists for an ESP fire or explosion. [Pg.373]

Carboprost has been used successfully to control postpartum bleeding that was secondary to loss of uterine tone and where the myometrium was unresponsive to oxytocin, ergonovine, or methylergonovine. Given intramuscularly, carboprost causes an almost immediate and sustained uterine contraction. Clinical experience has shown that the use of this agent has saved many women from operative interventions (including hysterectomy) to control postpartum hemorrhage. [Pg.719]

A policy of a three level safety design was also adopted. This includes the use of utilities and safety devices. An orthogonal design was used such that interruption of any part of these services would not affect the remaining sections. Manual bypasses were also provided in order to permit operator intervention at any point in the process. Finally, any releases of material from any of the relief devices were directed into secondary holding vessels in order to prevent releases into the atmosphere. [Pg.445]


See other pages where Operator intervention is mentioned: [Pg.1744]    [Pg.181]    [Pg.278]    [Pg.421]    [Pg.259]    [Pg.25]    [Pg.871]    [Pg.322]    [Pg.28]    [Pg.28]    [Pg.21]    [Pg.161]    [Pg.172]    [Pg.43]    [Pg.367]    [Pg.491]    [Pg.62]    [Pg.5]    [Pg.191]    [Pg.250]    [Pg.291]    [Pg.91]    [Pg.70]    [Pg.227]    [Pg.506]    [Pg.155]   