Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Collection period

HyperChem run s the molecular dynain ics trajectory, averaging and analyzing a trajectory and creating the Cartesian coordinates and velocities, fhe period for reporting these coordinates and velocities is th e data collection period. At-2. It is a m iiltiplc of the basic time step. At = ii At], and is also referred to as a data step. The value 1I2 is set in the Molecular Dynamics options dialog box. [Pg.318]

At, etc. The Snapshot period is specified 111 the Snapshot dialog bo by n, data steps, i.e. as a ni ii Itiple of the data collection period, At4 = n4 i3t2. [Pg.319]

TlyperCi hem updates the screen diirin g a trajectory at regular in ter-vals so yon can visiiali/e the irajectory. Since this screen update may slow down a trajectory If it occurs too frequently, yon c.an specify the duration of the Screen Refresh period At.,. The screen updates at ilines tQ, Iq + Atj, to + 2Atj, etc. The Screen Refresh period is specified in the Molecular Dynamics options dialog box by n 5 data steps, i.e. as a m iiliiplc of the data collection period, At5 = n 5 At2-... [Pg.319]

Alternatively, it is good practice to have a low average collection period, as given by... [Pg.851]

An accounts-receivable-turnover ratio of 12 is considered fairly good for a manufacturing company This implies an average collection period of about 1 month. The price obtained for the goods should include an allowance for interest (otherwise obtainable) on the money tied up for such a period. [Pg.851]

Figure 15-1 shows the Los Angeles, California, basin stationary air monitoring network, one of the most extensive in the United States (6). At most of these locations, automated instruments collect air quality data continuously. Five pollutant gases are monitored, and particulate matter filter samples are collected periodically. [Pg.218]

It may have been possible to implement very obvious waste-reduction measures already, before embarking on obtaining a material balance (even as early as at the end of Phase I). You should now consider the material balance information in conjunction with visual observations made during the data-collection period, to pinpoint areas or operations where simple adjustments in procedure could greatly improve the efficiency of the process by reducing unnecessary losses. [Pg.380]

When existing factories are being examined, the floor areas occupied by the various items of equipment can be measured on site during the data-collection period. It is important to consider and include the equipment outline (maximum travels), space for maintenance activity, operator movement and the handling of material and workpieces. In many cases, the space needed for handling exceeds that required accommodating the operative part of the equipment. Aisle space is also needed for through-shop movement. [Pg.74]

This is sometimes refined by deducting the sales for the current period as being not yet payable and therefore leaving figure to represent overdue debt only. The ratio is also known as collection period. [Pg.1030]

For abstracts printed since 1967 (the eighth collective period and later), CA can be searched by computer online. For a discussion of online searching see pages. 1616, 1631. [Pg.1614]

Urine may be collected for assays of enzyme activities following cleansing of the genitalia with mild antiseptic soap followed by rinsing with water. The urine is collected in a chemically clean container with no preservative. As the activity of urinary enzymes is a function of the volume of the specimen it is important to time the collection accurately. A collection period of 8 hours is quite adequate, and the use of longer periods is not desirable because enzyme activities can rapidly decrease in the relatively hostile medium of the urine. The urine should be refrigerated and transferred promptly to the laboratory, where it should also be processed promptly. [Pg.192]

Figure 2. Pectins isolated from faeces of germfree rats (collecting period I). Figure 2. Pectins isolated from faeces of germfree rats (collecting period I).
Figure 3. High molecular and partially degraded pectins isolated from faeces of some conventional rats (collecting period II)... Figure 3. High molecular and partially degraded pectins isolated from faeces of some conventional rats (collecting period II)...
After a 4 h collection period Fe-PS uptake rates were determined as a parameter for putative phytotoxic effects of the antibiotica treatments, n.d. = not determined. [Pg.49]

Considerations in designing a market basket survey also include the period of time over which product samples will be collected. For example, should samples be collected over one year to illustrate an annualized perspective on the data of interest, or is the issue more aptly addressed with a shorter collection period such as one season or one month ... [Pg.232]

The training of LSMBS shoppers is generally conducted by telephone and through written instructions. The written instructions and forms provided to the shoppers form the equivalent of a standard operating procedure (SOP). Often, since the network of shoppers is widely dispersed and may or may not be involved with more than one sample collection period, formal SOPs are not devised and provided to the shoppers. Instead, complete written instructions are provided, albeit not necessarily in SOP format. [Pg.240]

The times of sample collection for a single paddy survey are set with respect to the application time, such as just before an application, immediately after, and 1, 3, and 7 days post-application, and at longer intervals as appropriate. For an area survey of water and waterway sediments, samples are usually collected periodically over a cultivation season focusing on the application time. [Pg.896]

The product of U X V equals the production of creatinine during the collection period and, at steady state, should equal 20 to 25 mg/kg per day for ideal body weight (IBW) in males and 15 to 20 mg/kg per day for IBW in females. If it is less than this, inadequate urine collection may have occurred, and CrCl will be underestimated. [Pg.1543]

Even in the nominal absence of laser fluctuations or other imagedegrading aberrations, the number of photons that hit the detector during the data collection period of the image (i.e., the exposure time for a CCD image or the pixel dwell time for a confocal image) will contain considerable noise. The photon count x follows a Poisson distribution (Fig. 7.7A) with mean value fi as... [Pg.334]

Van den Berg and Huang [600] carried out direct electrochemical stripping of dissolved vanadium in seawater using cathodic stripping. Voltammetry was performed with a hanging mercury drop electrode. The detection limit was 0.3 nmol/1 after a collection period of 2 min. [Pg.231]

The purpose of this review is to provide the reader with a scenario of what can be accomplished with nickel complexes. It is useful to do this via a series of broad schemes, hypothetical in some cases, which show the main reaction patterns, without considering mechanistic details. Examples will illustrate the various processes, but extension to other substrates or to different conditions often requires use of alternative ligands or solvents, or a change from a neutral complex to a cationic or anionic species, as indicated above. For references to syntheses with nickel see Baker et al. (10). For criteria for the synthesis of coordination compounds and stability of organotransition metal complexes in general, see references (11. 12). Organometallic literature has been collected periodically by Bruce (13). [Pg.197]

TEQ calculations were made based on both - the WHO-TEFs and I-TEFs for seventeen 2,3,7,8-substituted PCDDs and PCDFs. Dioxin like PCBs were not measured. Total WHO-TEQ PCDD/F values for the analyzed samples range from 53.50 to 65.26 ng/kg dry mass. Calculations, based on I-TEFs were also made, to allow comparison with the literature data. The variation in the TEQ concentration may be attributed to varying loads during the sample collection period. Obtained results are higher, than medium... [Pg.209]

When male Wistar rats were exposed to -hexane at concentrations up to 3,074 ppm for 8 hours, analysis of urine showed that 2-hexanol was the major metabolite, accounting for about 60-70% of the total metabolites collected over the 48-hour collecting period (Fedtke and Bolt 1987). This is in contrast to humans, in which the major urinary metabolite is 2,5-hexanedione (Perbellini et al. 1981). The amounts of metabolites excreted were linearly dependent on the exposure concentration, up to an exposure of about 300 ppm. 2-Hexanol and 2-hexanone were detected in the first sample (obtained during the 8-hour exposure) excretion of 2,5-hexanedione was delayed and was not detected until 8-16 hours after exposure began. The amount of 2,5-hexanedione detected depended on sample treatment total excreted amounts over 48 hours were approximately 350 g/kg 2,5-hexanedione without acid treatment and 3,000 g/kg with total acid hydrolysis, indicating conversion of 4,5-dihydroxy-2-hexanone with acid treatment. [Pg.100]

The diet treatments were level of phytate intake, either 0.2 or 2.0 g/day. Each level was consumed for 15 days, three consecutive repeats of the 5-day menu cycle. To provide 2.0 g/day of phytic acid, 36 g of wheat bran was baked into 6 muffins and two muffins were eaten each meal. Dephytinized bran was prepared by incubating the bran in water and allowing the endogenous phytase to hydrolyze the phytate, then the entire incubation mixture was freeze-dried (4) and 36 g baked into 6 muffins. Thus, the intake of all nutrients and neutral detergent fiber was the same for both phytate intakes. Five subjects consumed the whole bran muffins for 15 days followed by the dephytinized bran muffins for 15 days and the other 5 subjects in the reverse order. Brilliant blue dye was given at breakfast on the first day of each collection period to aid in demarcation of stools. Stool composites were made for days 1-5, 6-15, 16-20 and 21-30 and urine composites for days 6-15, and 21-30. Daily food composites were made, homogenized, freeze-dried and then analyzed to determine mineral nutrient intakes. [Pg.66]


See other pages where Collection period is mentioned: [Pg.318]    [Pg.318]    [Pg.318]    [Pg.318]    [Pg.318]    [Pg.318]    [Pg.319]    [Pg.843]    [Pg.844]    [Pg.851]    [Pg.44]    [Pg.47]    [Pg.50]    [Pg.867]    [Pg.1543]    [Pg.54]    [Pg.382]    [Pg.173]    [Pg.229]    [Pg.1262]    [Pg.368]   
See also in sourсe #XX -- [ Pg.119 ]




SEARCH



Average collection period

The Data Collection Period

© 2024 chempedia.info