The left-hand side of equation (9.124) is called the 2-norm of the input signal v (t) squared . Norms are mathematical measures that enable objects belonging to the [Pg.304]

For a realizable eontroller to exist, all external signals that enter the eontrol loop must be bounded. [Pg.305]

7 H2- and Hoo-optimal control 9.7.1 Linear quadratic H2-optimal control [Pg.305]

The sealar version of equation (9.48), when u(t) is not eonstrained, and Q is unity, is ealled the Integral Squared Error (ISE), i.e. [Pg.305]

The //2-optimal eontrol problem is to find a eontoller c(t) sueh that the 2-norm of the ISE (written e(t) 2) is minimized for just one speeifie input v(t). [Pg.305]


A distributed control system (DCS) normally uses input and output modules which contain eight, sixteen, or more inputs or outputs. Failure of the module will simultaneously disable a large number of control loops. Attention to the assignment of input/output points to the modules makes the plant more tolerant of a failure of an input or output module (CCPS, 1993a). For a more detailed discussion of process control systems, see the process control part of Section 4.4, and Sections 6.4 and 6.5. [Pg.51]

Depending on the control system and components selected, the process variable from the sensors and signals to the actuator control unit is connected either directly or through transducers. Normally, the input and output are adjusted from pneumatic sensors and control units. The signals produced then are transformed into standard electronic values before connecting to the controller s input and output modules,... [Pg.776]

In thermal models, the ventilation airflow rates normally arc input parameters, to be defined by the user or to be calculated by the program on the basis of a nominal air exchange or flow rate) and some control parameters (demand-controlled ventilation, variable air volume flow ventilation systems), in airflow models, on the other hand, room air temperatures must be defined in the input (see Fig. 11.49). [Pg.1095]

The above example shows why it is mathematically more convenient to apply step changes rather than delta functions to a system model. This remark applies when working with dynamic models in their normal form i.e., in the time domain. Transformation to the Laplace domain allows easy use of delta functions as system inputs. [Pg.546]

In the classical model of basal ganglia function, neurons in the direct pathway were conceptualized as bearing Dl receptors and co-expressing substance P and dy-norphin. Neurons in the indirect pathway had Dj receptors and co-expressed enkephalin. The direct pathway was viewed as releasing movement through disinhibition of the thalamus, whereas enhancing the excitatory activity of the indirect pathway decreased motor activity (Chevalier and Deniau, 1990). This system of checks and balances can be disrupted in several ways. When there is a decrease of normal dopaminergic input, as it is in PD, the excessive output from... [Pg.154]

The normalized deposition rate is the only form of deposition rate that can be used to compare deposition characteristics of different monomers with different chemical structures and molecular weights under different discharge conditions (flow rate, system pressure, and discharge power). Similarly, WjFM can be considered as the normalized power input. When only one monomer is employed, D.R. can be used to establish the dependency of deposition rate on operational parameters. Even in such a simple case, D.R. cannot be expressed by a simple function of W or F, and its relationship to those parameters varies depending on the domain of plasma polymerization. [Pg.156]

Thus, the material formation in the luminous gas phase (deposition G), which is given in the form of normalized deposition rate (D.R./F Af), can be controlled by the composite parameter WjFM (normalized energy input parameter), which represents the energy per unit mass of gas, J/kg. Because of the system-dependent nature of LCVD, WjFM is not an absolute parameter and varies depending on the design factor of the reactor. The value of WjFM in a reactor might not be reproduced in a different reactor however, the dependency remains the same for all deposition G. [Pg.156]

While the substance can be an element such as calcium or zinc, or a compound such as amino acids, proteins, or sugars that exist normally in the body, in this chapter, it will be assumed to be a drug that is not normally present in the system. Thus, in this chapter, the pharmacokinetics of a drug is defined as its spatial and temporal distribution in a system. Unlike substances normally present, input of drugs into the system occurs only from exogenous sources. In addition, unless otherwise noted, the system under consideration will be the whole body. It should be noted that this definition of pharmacokinetics differs somewhat from the more conventional definition given in Chapter 1. The reason for this is seen in the following section. [Pg.90]

Virtually all known cytokines and their receptors have been found in many different types of cells in the central nervous system.54 For example, IL-1(3 is produced locally in the brain by neurons, microglia and astrocytes.55 Normally, there is little active production of proinflammatory cytokines in the brain itself due mainly to the fact that intact, functional neurons strongly suppress immune reactivity both in surrounding glia cells and in the neurons themselves.56 Results of experiments in which neuronal bodies have been damaged or normal physiological input into innervated target tissue has been disrupted show that this coincides with the de novo expression of major histocompatibility complex (MHC) molecules of class I and II, which are conditionally involved in adaptive immune responses (see Chapter 4). [Pg.131]

No validation of the computer system used to generate batch records and print/reconcile labels to include such items as source code inspection, testing before installation, use and testing after installation involving nominal (normal range) input values, boundary input values at and outside of normal input limits, invalid or unexpected input values and data volume and environmental extremes. [Pg.83]

The goal of this usability evaluation study was to show that two handed interaction and speech can be naturally adopted by users, and that two-handed interaction or speech helps to reduce the cognitive load and necessary attention compared to normal mouse input. Next section presents informally the system on which the usability evaluation has been carried out. Then, the experiment (participants, setup and procedure) will be detailed. The section is concluded with the presentation of the results of the experiment and their interpretation according to the hypothesis presented above. [Pg.414]

Charge acceptance of the silver—2inc system is normally on the order of 95—100% efficient based on coulombic (ampere-hour output over input) values. This is tme of any of the charging methods when carried out in the proper manner. Thus overcharge is rarely necessary in charging silver—2inc cells and batteries. [Pg.556]

To allow flexibility, the database manager must also perform point addition or deletion. However, the abihty to create a point type or to add or delete attributes of a point type is not normally required because, unlike other data processing systems, a process control system normally involves a fixed number of point types and related attributes. For example, analog and binary input and output types are required for process I/O points. Related attributes for these point types include tag names, values, and hardware addresses. Different system manufacturers may define different point types using different data structures. We will discuss other commonly used point types and attributes as they appear. [Pg.773]

Consider the speed-load (drooping) characteristics of the two machines as shown in Figure 16.20. For ease of illustration, the slopes have been exaggerated. Normally they are within 4% of the rated speed, as discussed earlier. When both machines are loaded equally, the total load may be defined by the load line AA, at the bus frequency,/ When the power input to PMf is increased, so that the drooping curve AO shifts to curve BO, it shifts the load line AA also to BB, so that the total load shared by the two machines will still remain the same. The load shared by G is now more than before at so that , > /, and by Gt less than before at P, so that P < Pi The generators now operate at a higher system frequency, /i,. If the... [Pg.517]

If the sampling time is one seeond and the system is subjeet to a unit step input funetion, determine the diserete time response. (N.B. normally, a zero-order hold would be ineluded, but, in the interest of simplieity, has been omitted.) Now... [Pg.205]

Except for special sihiations, pressure relief devices are not provided for fire exposure of heat exchangers, air fins, or piping, nor are the exposed surfaces of such items included for calculating the fire exposure heat input. Special situations may be congestion and substandard spacing, or unusually large equipment with normal liquid holdup over about 4 m and/or which represents over 15% of the total wetted surface of the system to which it is directly connected for pressure relief. [Pg.123]

Loss of Heat in Series Fractionation System - In series fractionation, i.e., where the bottoms from the first column feeds into the second column and the bottoms from the second feeds into the third, it is possible for the loss of heat input to a column to overpressure the following column. Loss of heat results in some of the light ends remaining with the bottoms and being transferred to the next column as feed. Under this circumstance, the overhead load of the second column may consist of its normal vapor load, plus the light ends from the first column. If the second column does not have the condensing capacity for the additional vapor load, excessive pressure could occur. [Pg.134]

Abnormal Process Heat Input - The required capacity is the maximum vapor generation rate at PR valve relieving conditions, including any noncondensibles produced from overheating, less the normal condensation or vapor outflow rate. In every case, one should consider the potential behavior of a system and each of its components. For example, the fuel or heating medium control valve or the mbe heat transfer may be the limiting consideration. Consistent with the practice... [Pg.134]

Abnormal Heat Input From Reboiler - Reboilers are designed with a specified heat input. When they are new or recently cleaned, additional heat input above the normal design can occur. In the event of temperature control failure, vapor generation may exceed the process system s ability to condense or otherwise absorb the buildup of pressure, which may include noncondensibles due to overheating. [Pg.135]

To make sure that all contractors and subcontractors maintain a minimum level of safety performance, the client, or general or main contractor, should establish standards for compliance. During the project planning stage, affected prime contractors should have an opportunity to provide input and resolve differences. Cross-cut committees are encouraged to allow prime contractors to standardize or normalize such essential elements as procedures, permit systems, and training. [Pg.31]


See other pages where Normalized system inputs is mentioned: [Pg.304]    [Pg.304]    [Pg.315]    [Pg.497]    [Pg.100]    [Pg.313]    [Pg.85]    [Pg.371]    [Pg.85]    [Pg.373]    [Pg.725]    [Pg.421]    [Pg.337]    [Pg.57]    [Pg.32]    [Pg.724]    [Pg.768]    [Pg.781]    [Pg.18]    [Pg.639]    [Pg.59]    [Pg.300]    [Pg.165]    [Pg.152]    [Pg.77]    [Pg.87]   
See also in sourсe #XX -- [ Pg.304 ]