Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Headspace type

The large-scale storage of fruit, particularly apples and pears, is now carried out under refrigeration ( 4°C) and in a chemically controlled atmosphere where the oxygen concentration is reduced to below 4% (v/v). The onset of fruit deterioration is heralded by the production of ethanol, which may be detected by online analyzers of the headspace type. [Pg.1168]

Maturation is conducted in closed, full containers to prevent oxidation and aerobic growth of microorganisms. Etee air contact with low alcohol wine soon leads to vinegar. Except for those sherry types already mentioned, wines ate exposed to air minimally and temporarily. During transfers incident to bulk storage and processing, some air exposure is almost inevitable, mote in total the longer the wine is held. In the cases of white and pink table wines, it is ordinarily as neat zero as possible, and stainless steel or other impermeable containers, inert gas headspace, etc ate employed. Red wines withstand and even benefit from small but repeated exposures to air. [Pg.374]

Pimento Berry Oil. The pimento or allspice tree, Pimenta dioca L. (syn. P. officinalis, Liadl.), a native of the West Indies and Central America, yields two essential oils of commercial importance pimento berry oil and pimenta leaf oil. The leaf oil finds some use ia perfumery for its resemblance to clove leaf and cinnamon leaf oils as a result of its high content of eugenol. Pimento berry oil is an item of commerce with extensive appHcation by the flavor industry ia food products such as meat sauces, sausages, and pickles, and moderate use ia perfumery, where it is used primarily as a modifier ia the modem spicy types of men s fragrances. The oil is steam-distilled from dried, cmshed, fully grown but unripe fmits. It is a pale yellow Hquid with a warm-spicy, sweet odor with a fresh, clean topnote, a tenacious, sweet-balsamic-spicy body, and a tea-like undertone. A comparative analysis of the headspace volatiles of ripe pimento berries and a commercial oil has been performed and differences are shown ia Table 52 (95). [Pg.337]

Corrosion has been encountered infrequently to date and has been a surface type, as opposed to pitting corrosion that can result in perforations. Entrapped air in the beverage or in the cans headspace increases the corrosive action of the product according to Koehler et at (21). As with beer and other canned foods, aluminum ends provide electrochemical protection when combined with tinplate or tin-free-steel can bodies. The level of iron pickup is reduced while the amount of aluminum dissolved in soft drinks increases without detrimental effect. Aluminum containers with vinyl epoxy and vinyl organosol coatings are compatible with carbonated soft drinks. [Pg.50]

Figure 8.26(A) is an example of a valve type interface [329]. Helium carrier gas is provided to the headspace saiq)ler and is split into two flow paths. One path is flow-controlled and provides a constant flow of carrier gas which passes from the headspace unit through the heated transfer line to the gas chromatograph. The second flow path is pressure-regulated and, in the standby mode, the seunple loop and seuapling needle are flushed continuously by the helium flow. At a time determined by the operator, the sampling needle pierces the septum and helium pressurizes the headspace vial to any desired pressure. The headspace gas is then allowed to vent through the sample loop. Once filled, the sample loop is placed in series with the normal carrier gas flow and its contents are driv Bbhrough the heated... Figure 8.26(A) is an example of a valve type interface [329]. Helium carrier gas is provided to the headspace saiq)ler and is split into two flow paths. One path is flow-controlled and provides a constant flow of carrier gas which passes from the headspace unit through the heated transfer line to the gas chromatograph. The second flow path is pressure-regulated and, in the standby mode, the seunple loop and seuapling needle are flushed continuously by the helium flow. At a time determined by the operator, the sampling needle pierces the septum and helium pressurizes the headspace vial to any desired pressure. The headspace gas is then allowed to vent through the sample loop. Once filled, the sample loop is placed in series with the normal carrier gas flow and its contents are driv Bbhrough the heated...
IMS can be used for chemical analysis of vapours from electronics packaging [287]. IMS-QMS has been used to analyse headspace vapours in sealed electronic packages [275,288] and to follow outgassing of polymers [287]. Various types of photoresist solvents, phtha-late plasticisers and other polymer additives, such as BHT, were detected. Other applications of IMS in semiconductor technology involve failure analysis control of the efficiency of cleaning and etching steps characterisation of process media and surveillance of the atmosphere of clean rooms. [Pg.417]

The purpose of in-use stability studies is to establish the period for which a product intended to be used on more than one occasion may be used after reconstitution or dilution or the withdrawal of the first dose from the container without adversely affecting the integrity of the product and with the product retaining acceptable quality characteristics. This type of test can be applied to any multiple use product (e.g., sterile products in multiple-use containers, powders or granules including those used to produce oral solutions or suspensions) but is likely to be of particular importance in the case of products that are manufactured with an inert headspace gas, for products containing antioxidants to protect an active ingredient that is liable to oxidative decomposition, and for products that contain a volatile antimicrobial preservative. [Pg.657]

Suitable PLOT columns for the determination of vinyl chloride monomer in PVC include 15.00 m, 0.53 mm bonded polystyrene-divinyl benzene and 30 m, 0.53 mm porous divinyl benzene homopolymer types. Typical responses for vinyl chloride monomer standards (0.06, 0.19 and 0.31 mg/1) in N,N-d imethylaceta-mide expressed as mg/kg vinyl chloride (PVC sample) using the 30 m homopolymer column and flame ionisation detection are shown in Figure 38. An automatic static headspace sampler was employed. [Pg.594]

The first results encouraged the authors to analyse, by headspace SPME, substances mentioned in ancient texts or hieroglyphics as components of embalming fluids [true resins such as mastic, labdanum and pine resin or pine pitch and gum resins such as olibanum, myrrh and galbanum] [27, 28] with the aim of finding characteristic chemical compounds for each type of resin or gum resin. [Pg.262]

Different types of equipment, depending on the resources available and the number of measurements required, can be used for determination of an OUR versus time curve. A rather simple and manually operated type was used by Bjerre et al. (1995). A still relatively inexpensive apparatus, simple to operate automatically, was designed by Tanaka and Hvitved-Jacobsen (1998). However, this type may introduce a minor error at especially low OUR values because of a potential release of oxygen into a headspace of nitrogen gas in the reactor. [Pg.178]

Various sample enrichment techniques are used to isolate volatile organic compounds from mammalian secretions and excretions. The dynamic headspace stripping of volatiles from collected material with purified inert gas and trapping of the volatile compounds on a porous polymer as described by Novotny [3], have been adapted by other workers to concentrate volatiles from various mammalian secretions [4-6]. It is risky to use activated charcoal as an adsorbent in the traps that are used in these methods because of the selective adsorption of compounds with different polarities and molecular sizes on different types of activated charcoal. Due to the high catalytic activity of activated charcoal, thermal conversion can occur if thermal desorption is used to recover the trapped material from such a trap. [Pg.246]

Arthur and Pawliszyn introduced solid-phase microextraction (SPME) in 1990 as a solvent-free sampling technique that reduces the steps of extraction, cleanup, and concentration to a unique step. SPME utilizes a small segment of fused-silica fiber coated with a polymeric phase to extract the analytes from the sample and to introduce them into a chromatographic system. Initially, SPME was used to analyze pollutants in water - via direct extraction. Subsequently, SPME was applied to more complex matrixes, such as solid samples or biological fluids. With these types of samples, direct SPME is not recommended nevertheless, the headspace mode (HSSPME) is an effective alternative to extracting volatile and semivolatile compounds from complex matrixes. (Adapted from Llompart et ah, 2001)... [Pg.219]

This was demonstrated by GC/MS measurements using a headspace sampler. Equivalent tissue segments of freshly enucleated and vitrectomised eyes of pig were prepared and rinsed for 30 min with PFD after a simulated VR surgery using different types of partially fluorinated liquids as endotamponade media. PFO was used as a reference. At the end of treatment, they were rinsed with PFD to clean the surfaces. [Pg.438]

Within a type of vial, the minimum and maximum vial size must be tested for each neck finish size. Within a size of vial, the maximum fill for that vial size is considered worst case, due to its having the smallest headspace. [Pg.530]

Type A accounts for a different proportion of milk samples, depending on geographic location, time, degree of agitation (Hyslop and Fox 1981), headspace atmosphere above the sample (Sweetsur and White... [Pg.596]

The second method is a similar procedure the cap of the product s container (plastic, glass or can) is punctured with a needle. Carbon dioxide is expelled from solution by vigorous shaking, and the headspace pressure is recorded. From the pressure rise, the volume of carbon dioxide dissolved in the product can be determined. This method is probably one of the most commonly used procedures for measuring carbonation however, the exact method used varies from one manufacturer to another. One supplier of this type of carbonation tester is Stevenson Reeves of Edinburgh, which also sells a slide rule to convert pressure rise measurements into carbonation levels. Information about their products can be found on their website (http //www.stevenson-reeves.co.uk). [Pg.254]

Gas Dispersion—Vessel Headspace Boerma and Lankester have measured the surface aeration of a nine-bladed disk-type turbine (note A well-designed pitched-blade turbine will give equd or better performance). In a fully baffled vessel, the optimum depth to obtain maximum gas dispersion was 15 to 50 percent of the impeller diameter. [Pg.105]


See other pages where Headspace type is mentioned: [Pg.35]    [Pg.35]    [Pg.320]    [Pg.214]    [Pg.66]    [Pg.139]    [Pg.203]    [Pg.204]    [Pg.459]    [Pg.53]    [Pg.15]    [Pg.258]    [Pg.207]    [Pg.66]    [Pg.672]    [Pg.2]    [Pg.146]    [Pg.155]    [Pg.233]    [Pg.157]    [Pg.158]    [Pg.192]    [Pg.315]    [Pg.142]    [Pg.33]    [Pg.321]    [Pg.103]    [Pg.382]    [Pg.1082]    [Pg.208]    [Pg.195]    [Pg.371]   
See also in sourсe #XX -- [ Pg.321 ]




SEARCH



Headspace

© 2024 chempedia.info