Surface aeration is most common in multiple impeller systems and/or semibatch and batch processes (Lines, 1999). Multiple impeller designs place an impeller relatively close to the surface that can induce surface aeration at relatively low impeller speeds. Most authors do not check for this phenomenon, and it is often unclear as to which models are used for the mass balance in the gas phase. The exclusion of a dynamic gas holdup term (assuming dynamic conditions) does not affect the results if surface aeration is limited however, if surface aeration is significant, experimental errors could be large (Figueiredo and Calderbank, 1979). [Pg.93]

The critical impeller speed for surface aeration (/Vcsa) can be identified using indirect sparging. A simple ki a versus N graph produces a sharp increase in ki a at iVcsA- Direct sparging makes this identification more difficult. Although gas may be entrained, additional gas dispersion does not occur until the impeller speed is increased by about 20% above the initial entrainment speed. Other factors [Pg.93]

Mass transfer by surface aeration is measured in the same ways as described in Section 4-7.5. If it is necessary to measure the gas induction rate in a closed [Pg.200]


The effective saturation depth,, represents the depth of water under which the total pressure (hydrostatic plus atmospheric) would produce a saturation concentration equal to for water ia contact with air at 100% relative humidity. This can be calculated usiag the above equation, based on a spatial average value of T, measured by a clean water test. For design purposes,, can be estimated from clean water test results on similar systems, and it can range from 5 to 50% of tank Hquid depth. Effective depth values for coarse bubble diffused air, fine bubble diffused air, and low speed surface aerators are 26 to 34%, 21 to 44%, and 5 to 7%, of the Hquid depth, respectively. [Pg.342]

Boermaand Lankester [Chem. E/ig. Sci., 23, 799 (1968)] have measured the surface aeration of a six-bladed disk-type turbine (note A well-designed pitched-blade turbine will give equal or better perfor-... [Pg.1422]

FIG. 14-103 Propeller-type surface aerator. (Ashhi ook-Simon-Haiiley Coip.)... [Pg.1424]

The wastewater enters the plant through the headworks where it passes through a bar screen, comminutor and Parshal flume. Following the headworks, the wastewater enters the aeration basin where floating surface aerator aerate and mix... [Pg.598]

Presence of crevices, dead-ends, etc. Effective protection by inhibitors relies on the continued access of inhibitor to all parts of the metal surface Aeration and Movement of the Liquid). It frequently happens that this condition is difficult to achieve due to the presence of crevices at joints, deadends in pipes, gas pockets, deposits of corrosion products, etc. Corrosion will then occur at these sites even though the rest of the system remains adequately protected. [Pg.784]

As is the case with pure bubble columns and gas-operated loop reactors, most bioreactors in technical use are aerated with oxygen or air. Reactors with pure surface aeration, such as roller bottles, shake flasks and small stirred reactors or special reactors with membrane aeration, are exceptions. The latter are used for the cultivation of cells and organisms which are particularly sensitive to shearing (see e. g. [28 - 29]). The influence of gas bubbles in increasing stress has been described in many publications (see e.g. [4, 27, 29, 30]). In principle it can be caused by the following processes ... [Pg.45]

Roberts PV, Dandliker PG. 1983. Mass transfer of volatile organic contaminants from aqueous solution to the atmosphere dirring surface aeration. Environmental Science and Technology 17 484-489. [Pg.287]

These are similar to stabilization ponds except that oxygen is added by mechanical surface aerators. This cuts the residence time of the water by 80%. It also means that the depth of the lagoons can be increased to 18 ft (5.5 m) and aerobic conditions can be maintained. The surface aerator power level is usually between 0.008 and 0.06 hp/1,000 gal (0.0002-0.016 hp/m3). This is not enough power to keep all the solids in solution. To do that would require 0.05-0.1 hp/1,000 gal (0.013-0.026 hp/m3).33... [Pg.447]

Tower Biology A biological waste-treatment process, developed from the Activated Sludge process. The sludge is contained in a tall tower, at the base of which oxygen is injected as small bubbles. The bubbles are almost completely absorbed by the time they reach the surface of the liquid. The system uses less energy than does surface aeration. Developed by Bayer in 1980 for its plant at Leverkusen, Germany subsequently adopted in India and then elsewhere. [Pg.273]

Fixed-roof tanks, 24 288-289 Fixed surface aerators, 26 159, 160 Fixed valve plates, 3 763-764 Fixing agents color film, 19 261 photographic, 19 213 Fixolide, 24 494 Flake... [Pg.362]

Surface aeration, 15 690 Surface aerators, 26 158, 159-161 high speed, 26 161 low speed, 26 161... [Pg.910]

Oxygen is consumed by micro-organisms as they utilise the substrate and also as a result of nitrification, but oxygen is gained by the river by processes of surface aeration, so that... [Pg.574]

When the surface aeration is significant, then the interfacial area is ... [Pg.711]

In these equations, a is the specific interfacial area for a significant degree of surface aeration (m2/m3), I is the agitator power per unit volume of vessel (W/m3), pL is the liquid density, o is the surface tension (N/m), us is the superficial gas velocity (m/s), u0 is the terminal bubble-rise velocity (m/s), N is the impeller speed (Hz), d, is the impeller diameter (m), dt is the tank diameter (m), pi is the liquid viscosity (Ns/m2) and d0 is the Sauter mean bubble diameter defined in Chapter 1, Section 1.2.4. [Pg.711]

Experimentation was carried out on a farm where a trial installation was set up, consisting of 4 storage tanks made of reinforced concrete, each with a utilizable volume of 100 m3 (Fig. 1). One tank was provided with a surface aerator (4 Kw) and a second with a mixer (1.3 Kw). [Pg.276]

Aeration basins are wastewater ponds or lagoons that have air introduced by mechanical action. Aeration may be performed to assist aerobic bioremediation and/or to remove volatile organic compounds. In an aeration basin, oxygen is usually supplied by surface aerators or by diffused aeration units. The action of the aerators and that of the rising air bubbles from the diffuser is used to keep the contents of the basin in suspension. Aeration is widely used in wastewater treatment and can be adapted to treat groundwater. [Pg.335]


See other pages where Aeration surface is mentioned: [Pg.341]    [Pg.167]    [Pg.179]    [Pg.185]    [Pg.185]    [Pg.284]    [Pg.293]    [Pg.294]    [Pg.1422]    [Pg.1423]    [Pg.1424]    [Pg.1424]    [Pg.2213]    [Pg.2220]    [Pg.2221]    [Pg.2221]    [Pg.2222]    [Pg.2223]    [Pg.2223]    [Pg.44]    [Pg.164]    [Pg.167]    [Pg.945]    [Pg.78]    [Pg.438]    [Pg.536]    [Pg.604]    [Pg.711]    [Pg.287]    [Pg.236]    [Pg.144]    [Pg.82]    [Pg.139]   