Monitoring and Measuring Devices

Control of Monitoring and Measuring Devices (Calibrate measuring equipment for valid results)... [Pg.171]

Control of monitoring and measuring devices - Maintain and calibrate measuring equipment... [Pg.232]

In addition, suitable equipment and suitable monitoring and measuring devices should be available so that the laboratory processes operate effectively. The procedures for the release of the laboratory product, i.e. the acceptance of the laboratoiy resnlts as well as that for the delivery of snch results to the customers, have to be specified and controlled. [Pg.62]

The company has planned and carried out production and service provisions under controlled conditions as applicable, including, but not limited to, the availability of information that describes the characteristics of the product, the availability of work instructions, the use of suitable equipment, the availability and use of monitoring and measuring devices, and the implementation of monitoring and measurement, and the implementation of release, delivery, and postdelivery activities. [Pg.97]

Even today, the determination of components at a concentration level of 100 ppm, including samples with complex matrices, poses no major problems and is routine in many laboratories. This is mainly due to the rapid development of instrumentation—the science of the construction and use of monitoring and measuring devices. Hence, we can expect the definition of the term trace component to change again soon. [Pg.501]

Trace analysis refers to analysis for a minor component in a homogenous mixture. The definition of the term trace analysis changes from time-to-time due to the rapid development of instrumentation or the use of sophisticated monitoring and measuring devices. By the current definition of the term trace component proposed by the International Union for Pure and Applied Chemistry, the limit above which the term trace analysis can be used is 100 ppm (100pgg ). Microanalysis is a special case of trace analysis and is concerned with the analysis of a single small particle or a minor constituent in a heterogenous mixture. Based on the analyte concentration in the sample to be examined, analytical methods and techniques are classified as below (see Table 2). The choice of analytical technique for a... [Pg.4501]

Manufacturers of enviromnental monitoring and measuring devices have a home in the Instruments Group of the International Safety Equipment Association (ISEA). Their products include fixed and portable air-sampling monitors, gas detector tubes and sampling pumps, passive dosimeters, and other instruments used in general industry, construction, and emergency response. I. i... [Pg.59]

Electronic demand limiting includes devices that monitor and measure the actual demand and provide control actions to limit the operation of attached devices when the measured demand reaches a specified value. These devices require two signals, the kilowatt hour (kWh) or demand pulse, which indicates the units of electrical energy consumed and a timing pulse, which indicates the end of one demand pulse and the start of the next one. [Pg.238]

The devices and analytical instruments that are used in the laboratory to monitor and measure various parameters during the laboratory activity shall be controlled in a way that ensures that they are consistent with the monitoring and measurement requirements. The laboratory shall determine the monitoring and measurements to be undertaken, establish processes to... [Pg.64]

The monitoring and measurement activities and devices needed to provide evidence of conformity are dehned to ensure consistency with the requirements. [Pg.372]

The current state of the art in terms of equipment and support measures had a significant effect on facility design. Of major importance was the availability of agent monitoring and detection devices, protective unitorms for personnel, and acceptable exhaust air filters, together with the capability to handle different types of decon solutions. [Pg.277]

Combined irradiation and measurement devices (7) have been constructed, which permit actinometric measurements and photokinetic experiments to be carried out at the same cuvette position. [One of these devices is available commercially (8).] Such experimental setups allow a time-resolved monitoring of the photoreaction (spectrally or at a single wavelength) and thus represent the most accurate way to perform actinometric measurements. However, only very few laboratories are equipped with such devices, and, generally, irradiation... [Pg.144]

In addition to the machine guarding, the control system should be interlocked with an electronically monitored failsafe system. The control software should have an awareness of the position and action of all moving parts and measurement devices. Therefore, if an unplanned incident or out-of-protocol action does occur, the system will take action or stop action to minimize the likelihood of additional safety hazards. In some cases, as with system calibration or super user access, graded access levels can be custom-built into the design for specialized and infrequent operations. [Pg.466]

Cybernetic monitoring modifies those sensors and measurement devices to be self-correcting, much as a home heating thermostat self corrects the room temperature by turning off the furnace (or on the air conditioner) when a pre-set temperature is reached. A cybernetic valve, for example, might increase or decrease aperture to adjust pressure in a column or chamber. [Pg.266]

There still remains one sticky issue. That issue relates to the difference between best performance and typical behavior just because drivers can be trained to correctly perceive time headways, will they then be inclined to adopt them and make them a part of their typical driving behavior or habits To answer that question we conducted one more study (Shinar and Schechtman, 2002) in which we installed headway monitoring and recording devices in the personal vehicles of 29 men and 14 women. All drivers had at least 5 years of driving experience, ranged in age from 25 to 60, and drove their car to and from work on a daily basis. The drivers were aware that a headway measuring device was installed in their vehicles, but were also told that the display unit will be installed a few weeks later. After approximately three weeks the display unit - that provided the driver with a continuous feedback of the time... [Pg.161]

The assessor should also find out whether an effective testing program is in place to help ensure the serviceability of process measurement equipment. The successful toller should have an established calibration program to address the accuracy of critical measurement equipment. Safety critical process parameters should be monitored and critical process equipment should automatically interlock when monitoring instrumentation detects safety critical deviations. Interlocks should either facilitate a remedy to the critical deviation or bring the process to the zero energy state. These instruments and interlocking devices should be routinely tested to ensure operational reliability. [Pg.29]

The principal requirement of a sampling system is to obtain a sample that is representative of the atmosphere at a particular place and time and that can be evaluated as a mass or volume concentration. Remote monitoring techniques are discussed in Chapter 15. The sampling system should not alter the chemical or physical characteristics of the sample in an undesirable manner. The major components of most sampling systems are an inlet manifold, an air mover, a collection medium, and a flow measurement device. [Pg.179]

This requirement hides an important provision. It not only applies to inspection, measuring, and test equipment but to the measurements that are performed with that equipment. Anywhere you intend performing product verification or monitoring processes you need to ensure that the environmental conditions are suitable. By environmental conditions is meant the temperature, pressure, humidity, vibration, lighting, cleanliness, dust, acoustic noise, etc. of the area in which such measurements are carried out. To avoid having to specify the conditions each time, you need to establish the ambient conditions and write this into your procedures. If anything other than ambient conditions prevail, you may need to assess whether the measuring devices will perform adequately in these conditions. If you need to discriminate between types of equipment, the ones most suitable should be specified in the verification procedures. [Pg.419]


See other pages where Monitoring and Measuring Devices is mentioned: [Pg.56]    [Pg.62]    [Pg.64]    [Pg.64]    [Pg.102]    [Pg.102]    [Pg.361]    [Pg.368]    [Pg.389]    [Pg.406]    [Pg.56]    [Pg.62]    [Pg.64]    [Pg.64]    [Pg.102]    [Pg.102]    [Pg.361]    [Pg.368]    [Pg.389]    [Pg.406]    [Pg.571]    [Pg.435]    [Pg.1571]    [Pg.749]    [Pg.368]    [Pg.179]    [Pg.305]    [Pg.954]    [Pg.95]    [Pg.83]    [Pg.409]    [Pg.190]    [Pg.15]    [Pg.1580]    [Pg.336]    [Pg.451]    [Pg.79]    [Pg.399]    [Pg.3]    [Pg.1129]   