Method quantitation limit

The achieved method quantitation limits (MQLs) allow the determination of dl-PCBs and the major PCBs well below the maximum limits set by the EU legislation (European Commission, 2011a,b). Also for BaP and the sum of BaP, BaA, BbFA and CHR, low MQLs of0.025 and 0.1 ig/kg could be achieved. The reported MQLs were defined by a S/N > 6 for the quantitative transition and S/N > 3 for the confirmation transition (European Commission, 2012). [Pg.677]

The purpose of a qualitative, quantitative, and characterization analysis is to solve a problem associated with a sample. A fundamental analysis, on the other hand, is directed toward improving the experimental methods used in the other areas of analytical chemistry. Extending and improving the theory on which a method is based, studying a method s limitations, and designing new and modifying old methods are examples of fundamental studies in analytical chemistry. [Pg.9]

Another type of experiment involves a fluid filament being drawn upward against gravity from a reservoir of the fluid (101,213,214), a phenomenon often called the tubeless siphon. The maximum height of the siphon is a measure of the spinnabiUty and extensional viscosity of the fluid. Mote quantitative measures of stress, strain, and strain rate can be determined from the pressure difference and filament diameter. A more recent filament stretching device ia which the specimen is held between two disks that move apart allows measurements ia low viscosity Hquids (215). AH of these methods are limited to spinnable fluids under small total strains and strain rates. High strain rates tend to break the column or filament. [Pg.192]

The U.S. FDA monitors foods for half of the approximately 300 pesticides having official EPA tolerances as weU as a number of other pesticides that have no official tolerances. Multiresidue methods, most of which are based on chromatography protocols, are employed (7). Not aU pesticides are monitored on aU foods and sampling (qv) is purposely biased to catch possible problems. The overaU iacidence of iUegal pesticide residue is, however, quite smaU 1% for domestic surveiUance samples and 3% for imported foods. The methods employed can usuaUy quantify residues present at 0.01 ppm. Quantitation limits range from 0.005 to 1 ppm. [Pg.241]

The method was validated in accordance to the guidelines of the international conference on harmonization (ICH). Data with respect to accuracy, within- and between run precision, recovery, detection and quantitation limits were reported and found to be within the accepted international criteria. Neither endogeneous substances nor the commonly used dmgs were found to interfere with the retention times of the analytes. Standard solutions of the dmg and quality control preparations at high and low level concentrations were demonstrated to be stable at room temperature and/or -20°C for long and short periods of time. [Pg.395]

Regulatory control is governmental imposition of limits on emission from sources. In addition to quantitative limits on emissions from chimneys, vents, and stacks, regulations may limit the quantity or quality of fuel or raw material permitted to be used the design or size of the equipment or process in which it may be used the height of chimneys, vents, or stacks the location of sites from which emissions are or are not permitted or the times when emissions are or are not permitted. Regulations usually also specify acceptable methods of test or measurement. [Pg.420]

Adequate sensitivity should be demonstrated and estimates of the limit of detection (LOD) and the limit of quantitation (LOQ) should be provided. The slope of the calibration line may indicate the ability of the method to distinguish the tme analyte concentration. The LOD of a method is the lowest analyte concentration that produces a reproducible response detectable above the noise level of the system. The LOQ is the lowest level of analyte that can be accurately and precisely measured. For a regulatory method, quantitation is limited by the lowest calibration standard. The techniques for these estimations should be described. [Pg.85]

Sensitivity is a measure of the smallest concentration that can be either measured [limit of detection (LOD)] or accurately quantitated [limit of quantitation (LOQ)]. In the USA, the method for measuring LOD or LOQ is left up to the method developer. European requirements for determining LOD and LOQ are very specific the LOD is based on the mean plus three standard deviations for 20 control blank samples, and the LOQ is defined as the lowest concentration giving an acceptable CV. [Pg.319]

The MDL and practical quantitation limit (PQL) should be appropriate for the objectives of the analysis. MDL refers to the minimum concentration of the compound of interest that can be measured and reported with a specified confidence (99% probability) that the concentration is above zero. The registrants must provide or develop an analytical method for water for the parent pesticide and its degradates that has an MDL of 0.01% of the label application rate (calculated as the average concentration in the top six inches of soil), or 0.05 pgL , whichever is lower. PQL refers to the lowest concentration at which the laboratory can confidently quantify the concentration of the compound of interest. The study authors must report all samples with concentrations above the MDL as detections, including those below the PQL in which the concentration cannot be quantified. In addition, the study authors must provide sample equations to demonstrate how the PQL was calculated. [Pg.612]

Method validation is needed to demonstrate the acceptability of the analytical method. A recovery test on a chemical being determined should be performed in order to verify the reliability of the series of analyses. Recovery studies are usually conducted by spiking untreated sediment with the target chemical at the deteetion limit, quantitation limit and in the range of 10-50 times the detection limit. The method is considered acceptable when the recoveries typically are greater than 70%. When the recovery is less than 70%, an improvement in the analytical methods is needed. Where this is not possible for technical reasons, then lower recovery levels may be acceptable provided that method validation has demonstrated that reproducible recoveries are obtained at a lower level of recovery. Analysis is usually done in duplicate or more, and the coefficient of variation (CV) should be less than 10% to ensure that recoveries will be consistently within the range 70-110%. [Pg.904]

Validate routine methods, i.e., define the conditions under which the assay results are meaningful.115 To do that, one must select samples that are truly representative of the product stream. This may be a difficult task when the process is still under development and the product stream variable. The linearity of detector response should be defined over a range much broader than that expected to be encountered. Interference from the sample matrix and bias from analyte loss in preparation or separation often can be inferred from studies of linearity. Explicit detection or quantitation limits should be established. The precision (run-to-run repeatability) and accuracy (comparison with known standards) can be estimated with standards. Sample stability should be explored and storage conditions defined. [Pg.43]

Quantitative XRF analysis has developed from specific to universal methods. At the time of poor computational facilities, methods were limited to the determination of few elements in well-defined concentration ranges by statistical treatment of experimental data from reference material (linear or second order curves), or by compensation methods (dilution, internal standards, etc.). Later, semi-empirical influence coefficient methods were introduced. Universality came about by the development of fundamental parameter approaches for the correction of total matrix effects... [Pg.631]

The version 1.0 bDNA assay was compared with the Monitor and NASB A HIV-1 RNA assays in three clinical evaluations (Coste et al., 1996 Revets et al., 1996 Schuurman et al., 1996). Coste et al. (1996) found that the sensitivity of the bDNA assay was lower (68.3%) than that of both the Monitor (93.3%) and NASBA (100%) assays for detection of HTV-1 RNA among 60 plasma specimens. When results with specimens for which the RNA levels were higher than the lower quantitation limit of each method were analyzed, the mean levels by Monitor, bDNA, and NASBA were 5.38 0.52,5.03 0.55, and 5.39 0.53 log10 copies/ml, re-... [Pg.225]

Dean et al. [93] used a high performance liquid chromatographic method for the simultaneous determination of primaquine and carboxyprimaquine in plasma with electrochemical detection. After the addition of the internal standard, plasma was deproteinized by the addition of acetonitrile. Nitrogen-dried supernatants, resuspended in mobile phase were analyzed on a C8 reversed-phase column. Limits of detection for primaquine and carboxyprimaquine were 2 and 5 ng/mL with quantitation limits of 5 and 20 ng/mL, respectively. The assay sensitivity and specificity are sufficient to permit quantitation of the drug in plasma for pharmacokinetics following low dose (30 mg, base) oral administration of primaquine, typically used in the treatment of malaria and P. carinii pneumonia. [Pg.192]

Valproic acid has been determined in human serum using capillary electrophoresis and indirect laser induced fluorescence detection [26], The extract is injected at 75 mbar for 0.05 min onto a capillary column (74.4 cm x 50 pm i.d., effective length 56.2 cm). The optimized buffer 2.5 mM borate/phosphate of pH 8.4 with 6 pL fluorescein to generate the background signal. Separation was carried out at 30 kV and indirect fluorescence detection was achieved at 488/529 nm. A linear calibration was found in the range 4.5 144 pg/mL (0 = 0.9947) and detection and quantitation limits were 0.9 and 3.0 pg/mL. Polonski et al. [27] described a capillary isotache-phoresis method for sodium valproate in blood. The sample was injected into a column of an EKI 02 instrument for separation. The instrument incorporated a conductimetric detector. The mobile phase was 0.01 M histidine containing 0.1% methylhydroxycellulose at pH 5.5. The detection limit was 2 pg/mL. [Pg.230]

For non-compendial procedures, the performance parameters that should be determined in validation studies include specificity/selectivity, linearity, accuracy, precision (repeatability and intermediate precision), detection limit (DL), quantitation limit (QL), range, ruggedness, and robustness [6]. Other method validation information, such as the stability of analytical sample preparations, degradation/ stress studies, legible reproductions of representative instrumental output, identification and characterization of possible impurities, should be included [7], The parameters that are required to be validated depend on the type of analyses, so therefore different test methods require different validation schemes. [Pg.244]

Before performing a validation method for a certain application, the scope of the method and its validation criteria should be defined first. The parameters to be investigated include compounds, matrices, types of formation, qualitative or quantitative method, detection or quantitation limit, linear range, precision and accuracy, types of equipment that will be used, and the location of the system. These steps of the validation method are illustrated in Fig. 1, which has been modified from Ref. [11],... [Pg.245]

In a bioanalytical method, analyses of blank samples (plasma, urine, or other matrix) should be obtained from at least six sources. Each blank sample should be tested for the possible interference of endogenous substances, metabolites, or degradation products. The response of the peaks interfering at the retention time of the analyte should be less than 20% of the response of a lower quantitation limit standard, and should be less than 5% of the response of the internal standard that was used [18, 19]. For dissolution studies, the dissolution media or excipients should not give a peak or spot that has an identical Rt or Rf value with the analyte [20]. [Pg.248]

The validation process begun in Phase I is extended during Phase II. In this phase, selectivity is investigated using various batches of drugs, available impurities, excipients, and samples from stability studies. Accuracy should be determined using at least three levels of concentration, and the intermediate precision and the quantitation limit should be tested. For quality assurance evaluation of the analysis results, control charts can be used, such as the Shewart-charts, the R-charts, or the Cusum-charts. In this phase, the analytical method is refined for routine use. [Pg.257]

MS has recently been used to measure compounds with significant levels of impurities and solubilities below the quantitation limits of other methods. Guo et al.46 described the use of LC/MS for solubility measurements in buffer solutions in a 96-well plate. Fligge et al.47 discussed an automated high-throughput method for classification of compound solubility. They integrated a Tecan robotic system for sample preparation in 384-well plates and fast LC/MS for concentration measurement. This approach is limited by LC/MS throughput. [Pg.239]


See other pages where Method quantitation limit is mentioned: [Pg.71]    [Pg.5]    [Pg.90]    [Pg.102]    [Pg.156]    [Pg.73]    [Pg.840]    [Pg.182]    [Pg.71]    [Pg.5]    [Pg.90]    [Pg.102]    [Pg.156]    [Pg.73]    [Pg.840]    [Pg.182]    [Pg.146]    [Pg.338]    [Pg.229]    [Pg.510]    [Pg.607]    [Pg.610]    [Pg.610]    [Pg.612]    [Pg.818]    [Pg.908]    [Pg.202]    [Pg.205]    [Pg.310]    [Pg.704]    [Pg.347]    [Pg.217]    [Pg.23]    [Pg.157]    [Pg.341]   