Analysis of noise is a more complex problem than that of dynamic behaviour and, moreover, it cannot be treated independently. The methodology for testing chromatographic devices in this respect seems to be underdeveloped. However, as it is not the intention of this chapter to attempt to remedy this situation, we shall retain the rather inexact terminology used thus far. [Pg.115]

Noise is generally defined as all variations of the output value that do not carry information on the parameter one wants to measure. In chromatographic practice, this general concept is divided into  [Pg.115]

Noise levels can be stated as voltages at the output of the device, as an absolute physical quantity or as concentration for a particular compound. Whenever possible, the second method is to be preferred, as it is independent of the compound being measured and allows a direct comparison of different devices. Therefore, for RI, permittivity, IR and UV-visible devices, noise levels in the appropriate physical quantity are given. For fluorimetry this is impossible. A number for the noise equivalent to quinine sulphate concentration is sometimes given. [Pg.116]

The demands on the detection limit of LC detectors can be roughly estimated as follows. Suppose that a volume is injected such that the resolution for the first peaks is increased by 5%, with a maximal allowable concentration of 521 of sample in the eluent, in order to preserve the linearity of isotherms, For the last peaks, with K-values of 10. this results in an elution concentration equivalent to 2000 p.p.ni. of sample in the eluent, owing to the increased dilution in the column for strongly retained peaks. If we wish to detect % of a constituent in the sample, the corresponding peak has a concentration of 20 p.p.m. For reasonable measurement, therefore, a noise level of 1 p.p.m. (r.m.s. value) is needed. This still precludes microanalysis or trace analysis. [Pg.116]

Preference is given to the expression of the upper limit or linearity in absolute units of the physical property being measured refractive index, dielectric constantj etc.), Or in concentration units(p.p.m.). The criterion for linearity is, whenever possible, taken as the point where a 10% deviation is observed. [Pg.116]


Information of the energy imparted to the entrance screen is then transferred through a number of conversions in the detector chain, which introduce pixel-to-pixel correlation, before it is stored as digital data. This correlation has to be considered to be able to predict absolute signal and noise levels in the stored, data the noise would otherwise be overestimated. [Pg.211]

The first of them to determine the LMA quantitatively and the second - the LF qualitatively Of course, limit of sensitivity of the LF channel depends on the rope type and on its state very close because the LF are detected by signal pulses exceeding over a noise level. The level is less for new ropes (especially for the locked coil ropes) than for multi-strand ropes used (especially for the ropes corroded). Even if a skilled and experienced operator interprets a record, this cannot exclude possible errors completely because of the evaluation subjectivity. Moreover it takes a lot of time for the interpretation. Some of flaw detector producers understand the problem and are intended to develop new instruments using data processing by a computer [6]. [Pg.335]

The influence of the reduced contrast sensitivity at low optical densities can be seen on the noise level, which increases with the wall thickness. [Pg.564]

A corresponding composite probe with the same frequency and crystal size, however, detects the test flaw much better the echo has a 12 dB higher amplitude (see Fig. 4) and in addition, the noise level is much lower, resulting in an improved signal to noise ratio. This effect is especially observed at high sound attenuation. However, in materials with low attenuation or in case of shorter sound paths the standard probe yields a comparable good signal to noise ratio. [Pg.709]

Ainong the first TFIz mixers to be constructed were those based on room-temperature Schottky diodes [11]. Over the past decade, new mixers based on superconducting tunnel junctions have been developed that have effective noise levels only a few tunes the quantum limit of [12]. Flowever, certain conditions... [Pg.1239]

Figure Bl.22.6. Raman spectra in the C-H stretching region from 2-butanol (left frame) and 2-butanethiol (right), each either as bulk liquid (top traces) or adsorbed on a rough silver electrode surface (bottom). An analysis of the relative intensities of the different vibrational modes led to tire proposed adsorption structures depicted in the corresponding panels [53], This example illustrates the usefiilness of Raman spectroscopy for the detennination of adsorption geometries, but also points to its main limitation, namely the need to use rough silver surfaces to achieve adequate signal-to-noise levels. Figure Bl.22.6. Raman spectra in the C-H stretching region from 2-butanol (left frame) and 2-butanethiol (right), each either as bulk liquid (top traces) or adsorbed on a rough silver electrode surface (bottom). An analysis of the relative intensities of the different vibrational modes led to tire proposed adsorption structures depicted in the corresponding panels [53], This example illustrates the usefiilness of Raman spectroscopy for the detennination of adsorption geometries, but also points to its main limitation, namely the need to use rough silver surfaces to achieve adequate signal-to-noise levels.
Handling of complex data sets Visual data mining methods especially show huge advantages over classical approaches if only Httle information about the data is known or if the expected patterns and relationships are not clearly defined. Furthermore, very inhomogeneous data sets or data with a high noise level can still be analyzed by these methods. [Pg.476]

Because of its small size and portabiHty, the hot-wire anemometer is ideally suited to measure gas velocities either continuously or on a troubleshooting basis in systems where excess pressure drop cannot be tolerated. Furnaces, smokestacks, electrostatic precipitators, and air ducts are typical areas of appHcation. Its fast response to velocity or temperature fluctuations in the surrounding gas makes it particularly useful in studying the turbulence characteristics and rapidity of mixing in gas streams. The constant current mode of operation has a wide frequency response and relatively lower noise level, provided a sufficiently small wire can be used. Where a more mgged wire is required, the constant temperature mode is employed because of its insensitivity to sensor heat capacity. In Hquids, hot-film sensors are employed instead of wires. The sensor consists of a thin metallic film mounted on the surface of a thermally and electrically insulated probe. [Pg.110]

As with a plasma-arc furnace, various gases and pneumatically conveyed soHds have been added to the various types of a-c open-arc furnaces to decrease alloy loss, to stabilize the arc, and to decrease the noise level, but with mixed commercial success. [Pg.122]

Fig. 13. Expected signal and noise levels for RE-TM alloys and Pt/Co multilayers (schematic). The total noise entering the SNR is the sum of the system noise, disk noise, and write noise. The system noise is electronic noise and photon shot noise and is comparable for disks with the same reflectivity. Fig. 13. Expected signal and noise levels for RE-TM alloys and Pt/Co multilayers (schematic). The total noise entering the SNR is the sum of the system noise, disk noise, and write noise. The system noise is electronic noise and photon shot noise and is comparable for disks with the same reflectivity.
Switching-Field Distribution. Both and have a strong relation with the recording process. determines the maximum output signal of a recording medium and hence the signal-to-noise ratio. ascertains how easily data can be recorded and erased or changed, but it also determines the maximum head field. On the other hand it also controls the ease with which data can be destroyed, eg, by stray fields. The lower the the more sensitive the medium is to all kinds of fields. In this way, influences the noise level as well. The squareness ratio S (= /Af ) can also be derived from the... [Pg.172]

Plant layout and noise suppression material are two general noise abatement methods. Plant layout does not affect noise levels at any given point however, noise can be abated by screening off a section of the plant. An example of this is to orient cooling towers with their closed faces toward the critical location. This method must also consider wind direction to balance air draft. Tankage can be located to act as a noise screen. [Pg.83]

Clean Air Act and its amendments ia 1970, 1977, and 1990 1967 Air Quahty Standards and National Air Pollution Acts and 1970 National Environmental PoHcy Act) (2) better waste disposal practices (1965 SoHd Waste Disposal Act 1976 Resource Conservation and Recovery Act) (see Wastes, industrial Waste treatment, hazardous wastes) (i) reduced noise levels (1972 Noise Control Act) (4) improved control of the manufacture and use of toxic materials (1976 Toxic Substances Control Act) and (5) assignment of responsibiUty to manufacturers for product safety (1972 Consumer Product Safety Act) (15,16). [Pg.92]

The electric motors are often the noisiest component of the centrifuge assembly. Most standard motors in the 75—250 kW range develop noise levels of 85 dbA (weighted sound pressure level using filter A, per the ANSI standard). A quiet motor can reduce this level by 5 dbA and should be used whenever noise is of concern. [Pg.405]

Equipment Materials and Abrasion Resistance. Stainless steel, especially Type 316, is the constmction material of choice and can resist a variety of corrosive conditions and temperatures. Carbon steels are occasionally used. Rusting may, however, cause time-consuming maintenance and can damage mating locating surfaces, which increases the vibration and noise level. Titanium, HasteUoy, or high nickel alloys are used in special instances, at a considerable increase in capital cost. [Pg.405]

Essential features of an automated method are the specificity, ie, the assay should be free from interference by other semm or urine constituents, and the sensitivity, ie, the detector response for typical sample concentration of the species measured should be large enough compared to the noise level to ensure assay precision. Also important are the speed, ie, the reaction should occur within a convenient time interval (for fast analysis rates), and adequate range, the result for most samples should fall within the allowable range of the assay. [Pg.392]

In general, low level detection is masked by the noise level inherent in any measuring device. Electrochemical methods are susceptible to electrical interference from external sources, variations in reference electrode parameters resulting from aging or contamination, and interference from redox... [Pg.110]

Detectors. The function of the gc detector is to sense the presence of a constituent of the sample at the outlet of the column. Selectivity is the property that allows the detector to discriminate between constituents. Thus a detector selective to a particular compound type responds especially weU to compounds of that type, but not to other chemical species. The response is the signal strength generated by a given quantity of material. Sensitivity is a measure of the abiHty of the detector to register the presence of the component of interest. It is usually given as the quantity of material that can be detected having a response at twice the noise level of the detector. [Pg.107]


See other pages where Noise levels is mentioned: [Pg.120]    [Pg.213]    [Pg.221]    [Pg.299]    [Pg.576]    [Pg.709]    [Pg.710]    [Pg.730]    [Pg.1023]    [Pg.1538]    [Pg.391]    [Pg.350]    [Pg.106]    [Pg.106]    [Pg.114]    [Pg.125]    [Pg.147]    [Pg.147]    [Pg.193]    [Pg.196]    [Pg.394]    [Pg.48]    [Pg.56]    [Pg.134]    [Pg.429]    [Pg.83]    [Pg.404]    [Pg.405]    [Pg.539]    [Pg.735]    [Pg.789]    [Pg.1079]    [Pg.1081]   
See also in sourсe #XX -- [ Pg.91 , Pg.151 , Pg.230 , Pg.235 , Pg.245 , Pg.246 , Pg.249 , Pg.257 , Pg.259 , Pg.267 , Pg.273 , Pg.274 , Pg.284 , Pg.295 , Pg.306 , Pg.321 , Pg.325 , Pg.327 , Pg.330 , Pg.341 , Pg.357 , Pg.369 , Pg.373 , Pg.374 ]

See also in sourсe #XX -- [ Pg.184 ]

See also in sourсe #XX -- [ Pg.91 , Pg.151 , Pg.230 , Pg.235 , Pg.245 , Pg.246 , Pg.249 , Pg.257 , Pg.261 , Pg.266 , Pg.271 , Pg.277 , Pg.278 , Pg.288 , Pg.299 , Pg.310 , Pg.325 , Pg.329 , Pg.331 , Pg.335 , Pg.345 , Pg.361 , Pg.373 , Pg.377 , Pg.378 ]

See also in sourсe #XX -- [ Pg.393 ]

See also in sourсe #XX -- [ Pg.10 ]

See also in sourсe #XX -- [ Pg.169 , Pg.170 ]

See also in sourсe #XX -- [ Pg.165 ]

See also in sourсe #XX -- [ Pg.23 ]

See also in sourсe #XX -- [ Pg.274 , Pg.276 , Pg.277 ]

See also in sourсe #XX -- [ Pg.50 ]




SEARCH



© 2024 chempedia.info