Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electrochemical testing

Membranes and Osmosis. Membranes based on PEI can be used for the dehydration of organic solvents such as 2-propanol, methyl ethyl ketone, and toluene (451), and for concentrating seawater (452—454). On exposure to ultrasound waves, aqueous PEI salt solutions and brominated poly(2,6-dimethylphenylene oxide) form stable emulsions from which it is possible to cast membranes in which submicrometer capsules of the salt solution ate embedded (455). The rate of release of the salt solution can be altered by surface—active substances. In membranes, PEI can act as a proton source in the generation of a photocurrent (456). The formation of a PEI coating on ion-exchange membranes modifies the transport properties and results in permanent selectivity of the membrane (457). The electrochemical testing of salts (458) is another possible appHcation of PEI. [Pg.14]

Use and Uimitations of Electrochemical Techniques A major caution must be noted as to the general, indiscriminate use of all electrochemical tests, especially the use of AC and EIS test techniques, for the study of corrosion systems. AC and EIS techniques are apphcable for the evaluation of very thin films or deposits that are uniform, constant, and stable—for example, thin-film protective coatings. Sometimes, researchers do not recognize the dynamic nature of some passive films, corrosion produc ts, or deposits from other sources nor do they even consider the possibility of a change in the surface conditions during the course of their experiment. As an example, it is note-... [Pg.2437]

Preparation of microporous carbons and their electrochemical testing... [Pg.375]

Wilde, B. E., A Critical Appraisal of Some Popular Laboratory Electrochemical Tests for Predicting the Localised Corrosion Resistance of Stainless Alloys in Sea-water , Corrosion, 28, 283 (1972)... [Pg.207]

Takenori, N., Norio, S., Tatsuo, 1. and Okamoto, G., Electrochemical Test for Pitting Corrosion in Stainless Steels , Hakkaido Daigaku Kogakubu Kenkyu Hokoku, 44, 1 (1967) C.A., 70, 16534h... [Pg.211]

There are several classes of test for hydrogen embrittlement, according to the application. Three general types of mechanical test can be identified, together with chemical and electrochemical tests intended to determine the hydrogen content of steels or the rate of entry of hydrogen from an environment. [Pg.1244]

The use of electrochemical tests for rapid assessment of the performance of these steels has attracted interest, and Pourbaix has devised an appa-... [Pg.1028]

Electrochemical tests This group includes the various electrochemical tests that have been proposed and used over the last fifty or so years. These tests include a number of techniques ranging from the measurement of potential-time curves, electrical resistance and capacitance to the more complex a.c. impedance methods. The various methods have been reviewed by Walter . As the complexity of the technique increases, i.e. in the above order, the data that are produced will provide more types of information for the metal-paint system. Thus, the impedance techniques can provide information on the water uptake, barrier action, damaged area and delamination of the coating as well as the corrosion rate and corroded area of the metal. However, it must be emphasised that the more comprehensive the technique the greater the difficulties that will arise in interpretation and in reproducibility. In fact, there is a school of thought that holds that d.c. methods are as reliable as a.c. methods. [Pg.1080]

One costly form of degradation is corrosion of metallic objects and structures. Organic coatings are widely used to protect these objects from corrosion. No completely acceptable and predictive methods exist for the evaluation of corrosion protection. Since corrosion is an electrochemical phenomenon, electrochemical testing may provide the evaluation tools which are wanting. [Pg.88]

Ringas and Robinson performed electrochemical tests on stainless steels and mild steels in three cultures of SRB. In all cases pitting resistance was lower in cultures of SRB. Potentiodynamic polarization... [Pg.243]

Electrochemical On-Line Corrosion Monitoring On-line corrosion monitoring is used to evaluate the status of equipment and piping in chemical process industries (CPI) plants. These monitoring methods are based on electrochemical techniques. To use on-line monitoring effectively, the engineer needs to understand the underlying electrochemical test methods to be employed. This section covers many of these test methods and their applications as well as a review of potential problems encountered with such test instruments and how to overcome or avoid these difficulties. [Pg.25]

Before electrochemical techniques are used in the evaluation of any situation involving microbes, tihe test protocol must receive considerable review by personnel quite experienced in both electrochemical testing and microbiologically influenced corrosion. It must be demonstrated that the method is capable of detecting and in some cases quantitatively measuring corrosion influenced by microbes. [Pg.28]

Environmental tests have been combined with conventional electrochemical measurements by Smallen et al. [131] and by Novotny and Staud [132], The first electrochemical tests on CoCr thin-film alloys were published by Wang et al. [133]. Kobayashi et al. [134] reported electrochemical data coupled with surface analysis of anodically oxidized amorphous CoX alloys, with X = Ta, Nb, Ti or Zr. Brusic et al. [125] presented potentiodynamic polarization curves obtained on electroless CoP and sputtered Co, CoNi, CoTi, and CoCr in distilled water. The results indicate that the thin-film alloys behave similarly to the bulk materials [133], The protective film is less than 5 nm thick [127] and rich in a passivating metal oxide, such as chromium oxide [133, 134], Such an oxide forms preferentially if the Cr content in the alloy is, depending on the author, above 10% [130], 14% [131], 16% [127], or 17% [133], It is thought to stabilize the non-passivating cobalt oxides [123], Once covered by stable oxide, the alloy surface shows much higher corrosion potential and lower corrosion rate than Co, i.e. it shows more noble behavior [125]. [Pg.274]

Electrochemical tests in half-cells allow the preliminary assessment of the WUT carbon as well as of the impact of grinding on the electrochemical performance. The data from the chart on the Figure 5 indicate that the material has high reversible capacity (similar to the capacities of the commercial graphites described earlier). [Pg.213]

The electrochemical testing of active materials has been performed on a 24-channel battery cycler (model BT2000 Basic Charge, available from Arbin Instruments of College Station, TX, USA). [Pg.233]

Thus, the electrochemical properties of the individual carbon materials are not so high as to enable their commercial usage in Li-ion batteries. In order to improve the performance, we started making composite materials from two individual carbon ingredients. Figure 1 shows a typical result of electrochemical tests of an electrode made of a blend of graphite and soft carbon treated at 1100°C (Cl 100) in comparison with the discharge curves of the individual constituents. [Pg.288]

Authors would like to express their gratitude to Dr. Kryukov V.V. (Kiev National University of Technologies and Design) for creation of original electrochemical test cells Dr. Chmilemko M.A. for the help in assembly of standard size 2016 elements (Interdepartmental Division of Electrochemical Power Energetic and Engineering, NAS of Ukraine), Dr. Matzui L. U. for her assistance with XRD investigations (Kiev National T. Schevchenko University). [Pg.329]

Preliminary electrochemical tests of materials obtained have been performed in two types of cells. Primary discharge measurements have been executed in standard 2325 coin-type cells (23 mm diameter and 2.5 mm height) with an electrolyte based on propylene carbonate - dimethoxyethane solution of LiC104. Cathode materials have been prepared from thermally treated amorphous manganese oxide in question (0.70 0.02g, 85wt%.) mixed with a conductive additive (10 % wt.) and a binder (5wt%). Lithium anodes of 0.45 mm thickness have been of slightly excess mass if compared to the stoichiometric amount, so as to ensure maximal possible capacity of a cell and full consumption of the cathode material. [Pg.484]

The mass losses for all samples are in a good agreement with values of water and hydroxide group content obtained by chemical analysis (Table 1). Thus, for electrochemical testing of Li- intercalation activity each sample was heated at 350°C to remove all types of bound water. [Pg.498]

Experimental CFTs were determined by Brigham and Tozer in three different ways based on chloride solutions two electrochemical and one chemical. In electrochemical testing in sodium chloride (NaCl) solution, the methods involved recording the current while either increasing the potential at suitable selected temperatures (apotentiodynamic test) or increasing the temperature at suitable fixed potentials (a potentiostatic test). Alternatively, a potential was established by the redox couple (Fe(in)/Fe(n) in a simple immersion test in ferric chloride solution. [Pg.284]

In a systematical study, Golovin et al. investigated a series of metallocene derivatives in terms of their redox potentials, mass transport properties, and chemical and electrochemical stabilities in both electrochemical test cells and commercial-size AA rechargeable cells.Figure 43 shows the complete voltammetric scan of the ferrocene-containing elec-... [Pg.135]

Electrochemical Characterization Technloues. Since corrosion Is an electrochemical process, It Is not surprising that a considerable amount of work has been reported over the years on electrical and electrochemical techniques for the study of the corrosion process. Leldhelser Ql.) and Szauer (12.> 11) have provided good reviews of the principal techniques. Walter has recently provided a review of DC electrochemical tests for painted metals (14). Both AC and DC methods have been employed to study a variety of Issues related to corrosion and corrosion protection. DC techniques are especially useful for studying substrate processes, while AC impedance techniques are most useful for studying processes relating to coated substrates and the performance of coatings. [Pg.7]


See other pages where Electrochemical testing is mentioned: [Pg.45]    [Pg.2429]    [Pg.2436]    [Pg.2439]    [Pg.2442]    [Pg.261]    [Pg.1004]    [Pg.1040]    [Pg.1113]    [Pg.120]    [Pg.243]    [Pg.18]    [Pg.20]    [Pg.22]    [Pg.24]    [Pg.24]    [Pg.271]    [Pg.282]    [Pg.52]    [Pg.209]    [Pg.378]    [Pg.484]    [Pg.487]    [Pg.706]    [Pg.346]   
See also in sourсe #XX -- [ Pg.181 ]




SEARCH



Conventions applicable to electrochemical measurements in corrosion testing

Corrosion testing continued electrochemical techniques

Corrosion testing continued electrochemical tests

Corrosion testing electrochemical

Corrosion testing electrochemical methods

Corrosion tests electrochemical polarization

Corrosion, metal electrochemical tests

Crack initiation electrochemical tests

Crevice corrosion electrochemical tests

Cyclic polarization, electrochemical tests

Dealloying electrochemical tests

Electrochemical half-cell testing

Electrochemical laboratory tests, soils

Electrochemical measurements corrosion testing

Electrochemical polarization corrosion testing

Electrochemical potentiokinetic reactivation tests

Electrochemical test data

Electrochemical testing techniques

Electrochemical testing, aluminum

Electrochemical testing, aluminum coatings

Electrochemical tests

Electrochemical tests

Electrochemical tests Subject

Electrochemical tests Tafel extrapolation

Electrochemical tests activation

Electrochemical tests alloy sensitization

Electrochemical tests anodized aluminum corrosion test

Electrochemical tests critical potential determination

Electrochemical tests cyclic potentiodynamic polarization

Electrochemical tests cyclic voltammetry

Electrochemical tests drawbacks

Electrochemical tests electrodeposited coatings

Electrochemical tests electrolytic corrosion test

Electrochemical tests electronics

Electrochemical tests films

Electrochemical tests galvanic corrosion

Electrochemical tests galvanostatic measurements

Electrochemical tests material behavior determination

Electrochemical tests measured parameters

Electrochemical tests metals processing

Electrochemical tests methods

Electrochemical tests organic liquids

Electrochemical tests polarization methods

Electrochemical tests potential probe methods

Electrochemical tests potentials

Electrochemical tests potentiodynamic methods

Electrochemical tests potentiostatic measurements

Electrochemical tests potentiostatic techniques

Electrochemical tests proteins effect

Electrochemical tests scratch repassivation

Electrochemical tests seawater

Electrochemical tests spectroscopy

INDEX electrochemical tests

Intergranular attack electrochemical tests

Laboratory testing electrochemical

Organic liquids electrochemical testing

Other Electrochemical Test Techniques

Pitting electrochemical tests

Test methods electrochemical aspects

Testing Electrochemical Impedance

Uniform corrosion electrochemical tests

© 2024 chempedia.info