Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Electrochemical half-cell testing

No or very little fiquid is used in the analytical process on dry reagent systems such as the Vitros and Reflotron Plus. For color reactions, the Vitros uses a multilayered, 16-mm square slide (Figure 11-3) in which reagents dispersed in emulsions are activated by diffusion of the specimen fluid into the layers. From three to seven layers containing reagents are used for each of the different tests available. The Vitros also uses slides for electrometric assays that incorporate miniature ion-selective electrodes. On these, a reference solution and patient specimen provide fluid that turns the electrodes into electrochemical half-cells (see Chapter 4). Slides of this type that measure sodium, potassium, carbon dioxide, and chloride are currently in use. [Pg.273]

Electrochemical leaching of Pt alloy catalysts has been deliberately applied to form core-shell materials with enhanced activities, either in half-cell tests [24, 25] or even... [Pg.412]

The other method that is used for catalyst electrochemical performance, is called half cell testing. Half cell apparatus can be used for different kinds of... [Pg.199]

Electrochemical tests in half-cells allow the preliminary assessment of the WUT carbon as well as of the impact of grinding on the electrochemical performance. The data from the chart on the Figure 5 indicate that the material has high reversible capacity (similar to the capacities of the commercial graphites described earlier). [Pg.213]

Both carbon materials were tested for their initial electrochemical performance in the 2-electrode electrochemical cells with Li metal as a counter electrode. Our findings have shown that with both types of carbon materials, achieving near theoretical reversible capacity upon Li+ deintercalation was possible. Thus, in a typical half cell environment (a CR2016 type coin cell with graphite and Li metal electrodes, a 1M LiPF6,... [Pg.335]

Basic electrochemical parameters of the tested materials were obtained using coin-type half-cells with metallic lithium as the counter electrode and IM LiPFe in EC/DEC (Merck) as electrolyte. The cells were galvanostatically charged/discharged at the current density 20 mA per gram of active mass. Full cylindrical Li-ion cells were manufactured in a laboratory scale using AA-size cases. Anode active masses after mixing with... [Pg.190]

Potentiometry is the measurement of an electrical potential difference between two electrodes (half-ceUs) in an electrochemical cell (Figure 4-1) when the cell current is zero (galvanic cell). Such a cell consists of two electrodes (electron or metallic conductors) that are connected by an electrolyte solution (ion conductor). An electrode, or half-cell, consists of a single metallic conductor that is in contact with an electrolyte solution. The ion conductors can be composed of one or more phases that are either in direct contact with each other or separated by membranes permeable only to specific cations or anions (see Figure 4-1). One of the electrolyte solutions is the unknown or test solution this solution may be replaced by an appropriate reference solution for calibration purposes. By convention, the cell notation is shown so that the left electrode (Mi,) is the reference electrode the right electrode (Mr) is the indicator (measuring) electrode (see later equation 3). ... [Pg.93]

The cathode material, Lao.. i(Sro,4oFeo.8oCoo.2o03.6 was synthesized by spray drying method. After calcination and ball-milling, the cathode powder was screen printed on a 5x5 cm half cell with a electroMe prepared by sol-gel method, using an ethyl cellulose binder and a terpineol-based solvent . The area of the cathode layers was 4x4 cm with a thickness of about 50 pm. The cathode was dried and no sinter process was carried out before the electrochemical cell test. [Pg.166]

An electrochemical test cell similar to that described in Pelaez et al. (2010) is used for the IS measurements in working conditions, meaning that the membranes are placed between the two half-cells in contact with NaCl aqueous solutions at the same concentration (electrode/solution (c)lmembranelsolutim (c)/electrode system) different NaCl concentrations between 0.001 and 0.05 M are typically measured. Before use, the membranes are maintained in contact with a solution of the studied concentration over a certain time (10 < t(h) < 24), depending on the membrane structure. In the case of dry membranes, the test cell consists of a Teflon structure on which two Pt electrodes are placed and screwed down (system electroddmembranel electrode) (Ramos et al. 2010). We will now discuss, in turn, the IS of these different membranes. [Pg.29]

Corrosion tests that are performed on lollipops are corrosion potential readings as described in ASTM C 876 (Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete), polarization resistance as described in ASTM G 59, using IR correction [3,9], and EIS [9]. Specimens are broken open to visually examine the bars for confirmation of the electrochemical results, and chloride analyses are performed. The chloride analysis correlates the chloride content to the corrosion activity. [Pg.408]


See other pages where Electrochemical half-cell testing is mentioned: [Pg.74]    [Pg.74]    [Pg.273]    [Pg.31]    [Pg.123]    [Pg.997]    [Pg.6]    [Pg.49]    [Pg.4]    [Pg.90]    [Pg.340]    [Pg.342]    [Pg.31]    [Pg.208]    [Pg.209]    [Pg.332]    [Pg.334]    [Pg.141]    [Pg.149]    [Pg.190]    [Pg.191]    [Pg.319]    [Pg.321]    [Pg.191]    [Pg.319]    [Pg.321]    [Pg.834]    [Pg.158]    [Pg.387]    [Pg.1365]    [Pg.39]    [Pg.47]    [Pg.1393]    [Pg.82]    [Pg.250]    [Pg.250]    [Pg.423]    [Pg.57]   


SEARCH



Electrochemical cell

Electrochemical half-cell

Electrochemical testing

Electrochemical tests

Half-cells

Testing test cells

Testing, cell

© 2024 chempedia.info