Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Information provided

The main purpose of AUGUR4.2 expert ISI is the application to zones where some flaws (indications) had been revealed by scheduled manual ultrasonic inspections. Information provided by AUGUR 4.2 is used for decision-making further surveillance of these zones or corrective measures. The procedure of AUGUR 4.2 examination is included into the approved general scheme of ISI [1]... [Pg.195]

The visual information provided by radiography images is complex, considering of the great number of disruptive factors. Processed images ate characterized by three particular phenomena ... [Pg.233]

The results found for the coating controlled parts allow to consider during the testing the exploitation of the information provided by the measured variation impedance for the processed products by the coating thickness determination and low frequency homogeneity and to evaluate the high frequency coating nature. [Pg.295]

During the eontrol by Eddy Current, we exploit the information provided from a distance by impedance variation of a solenoid to the vicinity of a conductor material. [Pg.349]

The computed CWT leads to complex coefficients. Therefore total information provided by the transform needs a double representation (modulus and phase). However, as the representation in the time-frequency plane of the phase of the CWT is generally quite difficult to interpret, we shall focus on the modulus of the CWT. Furthermore, it is known that the square modulus of the transform, CWT(s(t)) I corresponds to a distribution of the energy of s(t) in the time frequency plane [4], This property enhances the interpretability of the analysis. Indeed, each pattern formed in the representation can be understood as a part of the signal s total energy. This representation is called "scalogram". [Pg.362]

This paper describes the development of a novel system for improving the quality of information provided by manual ultrasonic examination of welds, while retaining the flexibility of the human operator to apply the techniques to components of a wide range of geometries and dimensions. The system, known as CamuS (Computer Aided Manual UltraSonics) provides assistance to the manual operator in two separate areas ... [Pg.765]

You will need to know addresses (http //www.) of the major Internet search engines. But search engines are still not perfected and the results may contain certain amount of noise, i. e, irrelevant information. Some companies use tricky things to get your attention we found many NDT related words like TOFD hidden as meta keywords in every page of some websites. If a search engine leads you to this site you will find no actual information provided, not even a single visible instance of the word TOFD. [Pg.976]

The invariant measure corresponding to Aj = 1 has already been shown in Fig. 6. Next, we discuss the information provided by the eigenmeasure U2 corresponding to A2. The box coverings in the two parts of Fig. 7 approximate two sets Bi and B2, where the discrete density of 1 2 is positive resp. negative. We observe, that for 7 > 4.5 in (15) the energy E = 4.5 of the system would not be sufficient to move from Bi to B2 or vice versa. That is, in this case Bi and B2 would be invariant sets. Thus, we are exactly in the situation illustrated in our Gedankenexperiment in Section 3.1. [Pg.112]

Using the information provided above, whieh of the C-H vibrational modes of benzene will be infrared-aetive, and how will the transitions be polarized How many C-H vibrations will you observe in the infrared speetrum of benzene ... [Pg.364]

Identify the following compounds on the basis of the information provided... [Pg.1023]

Random coils. Equation (9.53) gives the Kirkwood-Riseman expression for the friction factor of a random coil. In the free-draining limit, the segmental friction factor can, in turn, be evaluated from f. In the nondraining limit the radius of gyration can be determined. We have already discussed f in Chap. 2 and (rg ) in this chapter and again in Chapter 10, so we shall not examine the information provided by D for the random coil any further. [Pg.625]

In many cases, optimized reaction buffers, nucleotides, and enzymes are packaged in kits along with detailed protocols by the manufacturers. Beyond the information provided by reagent manufacturers, laboratories need a coUection of experimental protocols (5,6). One such coUection is distributed on a subscription basis and updated quarterly (5). [Pg.233]

Database Producers. Producers of databases, also known as database pubHshers or information providers, determine the content of the databases, produce them, and typically lease or Hcense them to private organi2ations or database vendors. Database producers may be categori2ed as government, not-for-profit, commercial/industrial, and mixed. [Pg.113]

Another technique often used to examine the stmcture of double-heUcal oligonucleotides is two-dimensional nmr spectroscopy (see AfAGNETiC SPIN resonance). This method rehes on measurement of the nuclear Overhauser effects (NOEs) through space to determine the distances between protons (6). The stmcture of an oligonucleotide may be determined theoretically from a set of iaterproton distances. As a result of the complexities of the experiment and data analysis, the quality of the stmctural information obtained is debated. However, nmr spectroscopy does provide information pertaining to the stmcture of DNA ia solution and can serve as a complement to the stmctural information provided by crystallographic analysis. [Pg.250]

The bulk of the patent specification is the disclosure, the text and illustrations that describe the claimed invention in detail and explain how the claimed invention differs from the prior art. Modem patent disclosures contain a summary of the claimed invention, a description of the background of the invention, a general description of the way in which the invention is made and used, specific examples, and, where appHcable, drawings of the invention in general or specific embodiments. The technical information provided in a patent specification may be used without infringing the patent only practicing the invention defined in the claims within the term and territory of the patent grant is forbidden. Because much of the information in patent specifications is never pubHshed in refereed journals or other nonpatent media, patent disclosures are an invaluable part of the technical Hterature. [Pg.45]

The first-cut sketch is usually not drawn to scale but is roughly spaced out. Figure 3 shows a first-cut layout. The utilisation of CAD on the first-cut layout can be beneficial when optimisation of the plot is necessary. Several important things should be noted in the first-cut layout sketch derived from key information provided by the process engineer. These items are indicated in the legend for Figure 3. [Pg.71]

This index lists the text pages on which quantitative information can be found relating to over 4000 specific heterocyclic compounds. In general the technique used (eg. H NMR) to measure the information has been given and not the type of information provided (eg. chemical shift values). The latter details may be found on the text pages themselves. [Pg.1]

In the use of temperature measurement for control of the separation in a distillation column, repeatability is crucial but accuracy is not. Composition control for the overhead product would be based on a measurement of the temperature on one of the trays in the rectifying section. A target would be provided for this temperature. However, at periodic intervals, a sample of the overhead product is analyzed in the laboratory and the information provided to the process operator. Should this analysis be outside acceptable limits, the operator would adjust the set point for the temperature. This procedure effectively compensates for an inaccurate temperature measurement however, the success of this approach requires good repeatability from the temperature measurement. [Pg.758]

Some of the preceding methods of computing depreciation are not allowed by taxation authorities in certain countries. When calculating depreciation, it is necessaiy to obtain details of the methods and rates permitted by the appropriate authority and to use the information provided. [Pg.806]

Must rely on certain information provided by the client Environmental issues due to unknown hazards from other ongoing tolls or a toller s past practices... [Pg.9]

Were there any unique safety considerations m the process If yes, was information provided by ABC Company adequate to ensure safe operations ... [Pg.148]

Did the Toller receive information on manufacturing implications of new products and major projects If not, was other information provided Does the Toller understand the information Was written acknowledgment obtained indicating that the information was received ... [Pg.167]

The world wide facilities for retrieving chemical information provided by the Chemical Abstract Service (CAS on-line) have made it a relatively easy matter to obtain CAS registry numbers of substances, and most of the numbers in this monograph were obtained via CAS on-line. We should point out that two other available useful files are CSCHEM and CSCORP which provide, respectively, information on chemicals (and chemical products) and addresses and telephone numbers of the main branch offices of chemical suppliers. [Pg.624]

Up to this point, you probably didn t understand the crucial importance of the pump curve. With the information provided in this chapter, and this book, we suggest that you immediately locate and begin using your pump curves with suction and discharge gauges on your pumps. [Pg.91]

Part of the design information provided by the software is the standard deviation multiplier, z, for eaeh eomponent toleranee shown in Figure 3.14 in Pareto ehart form. Additionally, sensitivity analysis is used to provide a pereentage eontribution of eaeh toleranee varianee to the final assembly toleranee varianee as shown in Figure 3.15. [Pg.127]

Static SIMS has been demonstrated to be a valuable tool in the chemical characterization of surfaces. It is unique in its ability to provide chemical information with high surface sensitivity. The technique is capable of providing mass spectral data (both positive and negative spectrometry), as well as chemical mapping, thereby giving a complete microchemical analysis. The type of information provided by... [Pg.556]

As I have said in previous editions the information provided in this volume is a distillation of the work of very many scientists, technologists, engineers, economists and journalists without which this book could not have existed. [Pg.931]


See other pages where Information provided is mentioned: [Pg.172]    [Pg.174]    [Pg.180]    [Pg.327]    [Pg.1033]    [Pg.317]    [Pg.491]    [Pg.56]    [Pg.1068]    [Pg.254]    [Pg.262]    [Pg.371]    [Pg.147]    [Pg.71]    [Pg.485]    [Pg.59]    [Pg.21]    [Pg.255]    [Pg.30]    [Pg.206]    [Pg.1]   
See also in sourсe #XX -- [ Pg.164 , Pg.165 ]




SEARCH