Limitations of apparatus

Guidance on the choice of respiratory protection for selected environments is given in Figure 13.6. All persons liable to use such protection should be fully trained this should cover details of hazards, limitations of apparatus, inspection, proper fitting of facepiece, testing, cleaning etc. [Pg.435]

The sample is burned in oxygen at 1000°C. Nitrogen oxide, NO, is formed and transformed into NO2 by ozone, the NO2 thus formed being in an excited state NO. The return to the normal state of the molecule is accompanied by the emission of photons which are detected by photometry. This type of apparatus is very common today and is capable of reaching detectable limits of about 0.5 ppm. [Pg.29]

The modification of the surface force apparatus (see Fig. VI-4) to measure viscosities between crossed mica cylinders has alleviated concerns about surface roughness. In dynamic mode, a slow, small-amplitude periodic oscillation was imposed on one of the cylinders such that the separation x varied by approximately 10% or less. In the limit of low shear rates, a simple equation defines the viscosity as a function of separation... [Pg.246]

Sensitivity levels more typical of kinetic studies are of the order of lO molecules cm . A schematic diagram of an apparatus for kinetic LIF measurements is shown in figure C3.I.8. A limitation of this approach is that only relative concentrations are easily measured, in contrast to absorjDtion measurements, which yield absolute concentrations. Another important limitation is that not all molecules have measurable fluorescence, as radiationless transitions can be the dominant decay route for electronic excitation in polyatomic molecules. However, the latter situation can also be an advantage in complex molecules, such as proteins, where a lack of background fluorescence allow s the selective introduction of fluorescent chromophores as probes for kinetic studies. (Tryptophan is the only strongly fluorescent amino acid naturally present in proteins, for instance.)... [Pg.2958]

The concentric cylinder viscometer described in Sec. 2.3, as well as numerous other possible instruments, can also be used to measure solution viscosity. The apparatus shown in Fig. 9.6 and its variations are the most widely used for this purpose, however. One limitation of this method is the fact that the velocity gradient is not constant, but varies with r in this type of instrument, as noted in connection with Eq. (9.26). Since we are not considering shear-dependent viscosity in this chapter, we shall ignore this limitation. [Pg.604]

Patent laws provide for several stages in the life of an application for a patent on an invention. The pattern followed by patent laws in effect in most industrialized countries during the nineteenth and early twentieth centuries, and still in effect in the United States in 1995, calls for the examination of all patent appHcations to certify that the claimed invention meets the national standards for novelty, usehilness, and inventiveness. The owner of the technology to be patented files appHcation papers that include a specification containing a description of the invention to be patented (called the disclosure) and claims defining the limits of the invention to be protected by the patent, a formal request for the issuance of a patent, and fees. Drawings of devices and apparatuses, electrical circuits, flow charts, etc, are an important part of the disclosures of most nonchemical and many chemical patents. [Pg.43]

Finally, instmmental broadening results from resolution limitations of the equipment. Resolution is often expressed as resolving power, v/Av, where Av is the probe linewidth or instmmental bandpass at frequency V. Unless Av is significantly smaller than the spectral width of the transition, the observed line is broadened, and its shape is the convolution of the instrumental line shape (apparatus function) and the tme transition profile. [Pg.312]

Data collected by modern analytical instalments are usually presented by the multidimensional arrays. To perform the detection/identification of the supposed component or to verify the authenticity of a product, it is necessary to estimate the similarity of the analyte to the reference. The similarity is commonly estimated with the use of the distance between the multidimensional arrays corresponding to the compared objects. To exclude within the limits of the possible the influence of the random errors and the nonreproductivity of the experimental conditions and to make the comparison of samples more robust, it is possible to handle the arrays with the use of the fuzzy set theory apparatus. [Pg.48]

Amplification methods. In determinations in which a very small amount of material is to be measured this may be beyond the limits of the apparatus available. In these circumstances if the small amount of material can be reacted in such a way that every molecule produces two or more molecules of some other measurable material, the resultant amplification may then bring the quantity to be determined within the scope of the apparatus or method available. [Pg.132]

The main limitation of HEX reactors is the short residence time, typically from a few seconds to a few minutes. Indeed, the apparatuses are smaller than the traditional ones and fast flow velocities are necessary in order to maintain good level of heat-transfer coefficients. However, as described in the previous paragraph, the highlighted transfer properties of HEX reactors allow us to operate in a few minutes, whereas it takes many hours in batch or semibatch mode. [Pg.263]

The arrangement of apparatus is usually dictated to some extent by the laboratory space available but within this limitation careful preliminary planning can make the construction, use and maintenance of the apparatus easier. The apparatus should be designed so that all parts are easily accessible and so that its operation does not impose too great a physical strain on the worker due to awkwardly placed components. An apparatus, badly designed in this respect, will probably be broken much more often than a more carefully planned one. [Pg.88]

The need to limit the maximum temperature rise has resulted in two main types of apparatus, illustrated in Fig. 20-25. The first consists of multicomponent ribbon separation units—apparatus capable of separating small quantities of mixtures which may contain few or many species. In general, such units operate with high voltages, low... [Pg.20]

The flash-point is a measure of the ease of ignition of the liquid. It is the lowest temperature at which the material will ignite from an open flame. The flash-point is a function of the vapour pressure and the flammability limits of the material. It is measured in standard apparatus, following standard procedures (BS 2000). Both open- and closed-cup apparatus is used. Closed-cup flash-points are lower than open cup, and the type of apparatus used should be stated clearly when reporting measurements. Flash-points are given in Sax s handbook, Lewis (2004). The flash-points of many volatile materials are below normal ambient temperature for example, ether —45°C, petrol (gasoline) —43°C (open cup). [Pg.364]

Fish tissue is homogenized with a Polytron apparatus using methanol as a solvent, or extracted in a ball mill with hexane. The extracts are evaporated to dryness, dissolved in ethyl acetate toluene, and cleaned up on a gel permeation column followed by an alumina column. Analysis is performed by GC/NPD (Muir et al. 1981). Recovery is acceptable (79-97%) and limit of detection is 10 ng/g (Muir et al. 1981). [Pg.321]

Details of the specific types of apparatus need not normally be given except for nonstandard processes. A flow chart of the manufacturing operation and the in-process controls (and acceptance limits) is required. Proposals for alternative processes will need to be supported by appropriate data to show that the finished products resulting from these are consistent with the finished product specification. Certain manufacturing operations such as mixing may require additional information on quality parameters monitored during production and prior to batch release. Appropriate quality parameters should be included in the finished product specification regardless of the outcome of validation studies (e.g., content uniformity for solid and semi-solid products). [Pg.659]

Puacz et al. (1995) developed a catalytic method, based on the iodine-azide reaction, for the determination of hydrogen sulfide in human whole blood. The method involves the generation of hydrogen sulfide in an evolution-absorption apparatus. In addition, the method allows for the determination of sulfide in blood without interference from other sulfur compounds in blood. A detection limit of 4 g/dm3 and a percent recovery of 98-102% were achieved. Although the accuracy and precision of the catalytic method are comparable to those of the ion-selective electrode method, the catalytic method is simpler, faster, and would be advantageous in serial analysis. [Pg.152]

Thus prokaryote cells have a very limited sense of the environment and a limited search apparatus (see Harold in Further Reading). [Pg.233]

Also, it seems that most of these properties are interdependent. For example, deaeration and permeability (Mainwaring and Reed, 1987) and perhaps the bulk density ratio (Jones and Mills, 1989) seem to provide an adequate mechanism to detect changes in material performance due to different particle size distribution, density and/or shape. However, possibly the greatest disadvantage or limitation of these empirical techniques is the need to standardize the experimental apparatus and techniques. For exam-... [Pg.729]

Seitz, Suydam, and Hercules 186> recently developed on the basis of luminol chemiluminescence a method for chromium-III ion determination which has a detection limit of about 0.025 ppb. The method is specific for free chromium-III ions as chromium-VI compounds have no catalytic effect and other metal ions can be converted to a non-catalytic form by complexing with EDTA, since the chromium-III complex of EDTA, which is in any case not catalytically active, is formed kinetically slowly 186>. To detect extremely small light emissions, and hence very small metal concentrations, a flow system was used which allows the reactants to be mixed directly in front of a multiplier. (For a detailed description of the apparatus, see 186>). [Pg.131]

To date, a few methods have been proposed for direct determination of trace iodide in seawater. The first involved the use of neutron activation analysis (NAA) [86], where iodide in seawater was concentrated by strongly basic anion-exchange column, eluted by sodium nitrate, and precipitated as palladium iodide. The second involved the use of automated electrochemical procedures [90] iodide was electrochemically oxidised to iodine and was concentrated on a carbon wool electrode. After removal of interference ions, the iodine was eluted with ascorbic acid and was determined by a polished Ag3SI electrode. The third method involved the use of cathodic stripping square wave voltammetry [92] (See Sect. 2.16.3). Iodine reacts with mercury in a one-electron process, and the sensitivity is increased remarkably by the addition of Triton X. The three methods have detection limits of 0.7 (250 ml seawater), 0.1 (50 ml), and 0.02 pg/l (10 ml), respectively, and could be applied to almost all the samples. However, NAA is not generally employed. The second electrochemical method uses an automated system but is a special apparatus just for determination of iodide. The first and third methods are time-consuming. [Pg.81]


See other pages where Limitations of apparatus is mentioned: [Pg.61]    [Pg.61]    [Pg.23]    [Pg.84]    [Pg.170]    [Pg.500]    [Pg.730]    [Pg.295]    [Pg.79]    [Pg.63]    [Pg.245]    [Pg.283]    [Pg.362]    [Pg.236]    [Pg.15]    [Pg.57]    [Pg.90]    [Pg.190]    [Pg.200]    [Pg.164]    [Pg.307]    [Pg.10]    [Pg.66]    [Pg.8]    [Pg.485]    [Pg.544]    [Pg.63]    [Pg.419]   
See also in sourсe #XX -- [ Pg.177 , Pg.180 ]