Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Elutions with

The enantiomeric excess of 3.10c has been determined by HPLC analysis using a Daicel Chiracel OD column and eluting with a 60 / 1 (v/v) hexane(HPLC-grade) / 2-propanol(p.a.) mixture. At a flow of 1 ml per minute the rentention times for the different isomers of 3.10c were 6.3 min. (exo, major enantiomer) 7.1 min. (exo, minor enantiomer) 7.7 min. (endo, major enantiomer) 10.7 min. (endo, minor enantiomer). [Pg.103]

In a chromatographic analysis of low-molecular-weight acids, butyric acid elutes with a retention time of 7.63 min. The column s void time is 0.31 min. Calculate the capacity factor for butyric acid. [Pg.552]

The identities of the solutes are defined such that solute A always has the smaller retention time. Accordingly, the selectivity factor is equal to 1 when the solutes elute with identical retention times, and is greater than 1 when is greater than fr A-... [Pg.552]

Now that we have defined capacity factor, selectivity, and column efficiency we consider their relationship to chromatographic resolution. Since we are only interested in the resolution between solutes eluting with similar retention times, it is safe to assume that the peak widths for the two solutes are approximately the same. Equation 12.1, therefore, is written as... [Pg.556]

Thus far all the separations we have considered involve a mobile phase and a stationary phase. Separation of a complex mixture of analytes occurs because each analyte has a different ability to partition between the two phases. An analyte whose distribution ratio favors the stationary phase is retained on the column for a longer time, thereby eluting with a longer retention time. Although the methods described in the preceding sections involve different types of stationary and mobile phases, all are forms of chromatography. [Pg.597]

The elution order for neutral species in MEKC depends on the extent to which they partition into the micelles. Hydrophilic neutrals are insoluble in the micelle s hydrophobic inner environment and elute as a single band as they would in CZE. Neutral solutes that are extremely hydrophobic are completely soluble in the micelle, eluting with the micelles as a single band. Those neutral species that exist in a partition equilibrium between the buffer solution and the micelles elute between the completely hydrophilic and completely hydrophobic neutrals. Those neutral species favoring the buffer solution elute before those favoring the micelles. Micellar electrokinetic chromatography has been used to separate a wide variety of samples, including mixtures of pharmaceutical compounds, vitamins, and explosives. [Pg.606]

Vitamin Bi is a cation and must, therefore, elute before the neutral species methanol thus it elutes first at 3.41 min. Vitamin B3 is a neutral species and should elute with methanol at 4.69 min. The remaining two B vitamins are weak acids that partially ionize in the pH 9 buffer. Of the two, vitamin Be is the stronger acid and is ionized (as the anion) to a greater extent. Vitamin Be, therefore, is the last of the vitamins to elute. [Pg.607]

Actinide ions of the 111, IV, and VI oxidation states can be adsorbed by cation-exchange resins and, in general, can be desorbed by elution with chloride, nitrate, citrate, lactate, a-hydroxyisobutyrate, ethylenediaminetetraacetate, and other anions (11,12). [Pg.215]

Highly pure / -hexane can be produced by adsorption on molecular sieves (qv) (see Adsorption, liquid separation) (43). The pores admit normal paraffins but exclude isoparaffins, cycloparaffins, and aromatics. The normal paraffins are recovered by changing the temperature and/or pressure of the system or by elution with a Hquid that can be easily separated from / -hexane by distillation. Other than ben2ene, commercial hexanes also may contain small concentrations of olefins (qv) and compounds of sulfur, oxygen, and chlorine. These compounds caimot be tolerated in some chemical and solvent appHcations. In such cases, the commercial hexanes must be purified by hydrogenation. [Pg.405]

Uranium ores are leached with dilute sulfuric acid or an alkaline carbonate [3812-32-6] solution. Hexavalent uranium forms anionic complexes, such as uranyl sulfate [56959-61-6], U02(S0 3, which are more selectively adsorbed by strong base anion exchangers than are other anions in the leach Hquors. Sulfate complexes are eluted with an acidified NaCl or ammonium nitrate [6484-52-2], NH NO, solution. Carbonate complexes are eluted with a neutral brine solution. Uranium is precipitated from the eluent and shipped to other locations for enrichment. Columnar recovery systems were popular in South Africa and Canada. Continuous resin-in-pulp (RIP) systems gained popularity in the United States since they eliminated a difficult and cosdy ore particle/leach hquor separation step. [Pg.387]

In the continuous process for producing phosphatidylcholine fractions with 70—96% PC at a capacity of 600 t/yr (Pig. 5) (16), lecithin is continuously extracted with ethanol at 80°C. After separation the ethanol-insoluble fraction is separated. The ethanol-soluble fraction mns into a chromatography column and is eluted with ethanol at 100°C. The phosphatidylcholine solution is concentrated and dried. The pure phosphatidylcholine is separated as dry sticky material. This material can be granulated (17). [Pg.101]

Chromatographic conditions elution with 50 50 methanol/water solvent at the rate of 1.5 ml,/min through a DuPont Zorbax ODS column using a Waters R-401 Refractive Index Detector. [Pg.147]

In the recovery of cadmium from fumes evolved in the Imperial Smelting process for the treatment of lead—zinc concentrates, cadmium is separated from arsenic using a cation-exchange resin such as Zeocarb 225 or Ambedite 120 (14,15). Cadmium is absorbed on the resin and eluted with a brine solution. The cadmium may then be recovered direcdy by galvanic precipitation. [Pg.387]

The residue is leached to give cesium sulfate solution, which can be converted to cesium chloride by ion exchange on Dowex 50 resin and elution with 10% HCl, treatment using ammonia or lime, to precipitate the alurninum, or by solvent extraction, followed by purification at neutral pH using hydrogen peroxide or ammonia. [Pg.376]

I have carried out widespread studies on the application of a sensitive and selective preconcentration method for the determination of trace a mounts of nickel by atomic absorption spectrometry. The method is based on soi ption of Cu(II) ions on natural Analcime Zeolit column modified with a new Schiff base 5-((4-hexaoxyphenylazo)-N-(n-hexyl-aminophenyl)) Salicylaldimine and then eluted with O.IM EDTA and determination by EAAS. Various parameters such as the effect of pH, flow rate, type and minimum amount of stripping and the effects of various cationic interferences on the recovery of ions were studied in the present work. [Pg.51]

In the recent years intensive studies related to modification of silica with organic compounds of various chemical nature have being conducted in order to concentrate selectively metal ions from solutions and then to perform their analytical determination directly in the sorbent phase, or after that, to elute with appropriate reagents in solution. [Pg.277]

A powerful tool now employed is that of diode array detection (DAD). This function allows peaks detected by UV to be scanned, and provides a spectral profile for each suspected microcystin. Microcystins have characteristic absorption profiles in the wavelength range 200-300 nm, and these can be used as an indication of identity without the concomitant use of purified microcystin standards for all variants. A HPLC-DAD analytical method has also been devised for measurement of intracellular and extracellular microcystins in water samples containing cyanobacteria. This method involves filtration of the cyanobacteria from the water sample. The cyanobacterial cells present on the filter are extracted with methanol and analysed by HPLC. The filtered water is subjected to solid-phase clean-up using C g cartridges, before elution with methanol and then HPLC analysis. [Pg.118]

This material Is purified by recrystallization from ethyl acetate acetone 2 1 (v v) to give a first crop (6.8 g), and by flash chromatography of the residue from the mother liquor, using 150 g of 230-400 mesh silica gel (Merck), a 40-mm diameter column, and elution with 10 1 (v v) ethyl acetate methanol. A fast moving orange band and a slower moving lemon-yellow band can be clearly seen on the column. The lemon-yellow hand is collected from the column and evaporation gives a second crop (1.4 g) of comparably pure material. The total yield of the pale yellow isoquinoline is 8.2 g (86t), mp 135-137°C (Note 10). [Pg.77]

The reaction can be conveniently monitored by TLC using silica plates and eluting with 1 4 ethyl acetate-heptane. [Pg.143]

Aromatic hydrocarbons can be purified as their picrates using the procedures described for amines. Instead of picric acid, 1,3,5-trinitrobenzene or 2,4,7-trinitrofluorenone can also be used. In all these cases, following recrystallisation, the hydrocarbon can be isolated either as described for amines or by passing a solution of the adduct through an activated alumina column and eluting with toluene or petroleum ether. The picric acid and nitro compounds are more strongly adsorbed on the column. [Pg.58]


See other pages where Elutions with is mentioned: [Pg.441]    [Pg.945]    [Pg.122]    [Pg.123]    [Pg.363]    [Pg.363]    [Pg.558]    [Pg.600]    [Pg.605]    [Pg.287]    [Pg.388]    [Pg.171]    [Pg.25]    [Pg.401]    [Pg.476]    [Pg.71]    [Pg.341]    [Pg.29]    [Pg.178]    [Pg.393]    [Pg.378]    [Pg.2063]    [Pg.2063]    [Pg.42]    [Pg.137]    [Pg.329]    [Pg.397]    [Pg.166]    [Pg.25]    [Pg.65]    [Pg.82]   


SEARCH



Electrofocusing in Sucrose Gradient with Voltage Applied During Elution

Elution lignin sulfonates with electrolyte

Elution of a Narrow Band with Competitive Langmuir Isotherms

Elution of a Wide Band With Competitive Langmuir Isotherms

Elution with Divalent Cations

Elution with Perchloric Acid and Sodium Perchlorate

Elution with electrolyte solution

Elution with water

Elutions with HEDTA

Lignin sulfonates elution with electrolyte solution

Lignin sulfonates elution with water

Molecularly imprinted solid phase extraction with pulsed elution

Routine with programmed elution

Sulfonated lignins elution with electrolyte solution

Sulfonated lignins elution with water

© 2024 chempedia.info