Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Development, automatic standard

The structure of peptides containing 20 eukaryotic natural amino acids is now routinely determined by the use of automatic protein microsequencer, which uses Edman chemistry to convert each a-amino acid sequentially to its phenylthiohydantoin (PTH) derivative. The formed PTH-amino acids can be identified by their retention times on HPLC systems by comparison with reference standards derived from the 20 natural amino acids. For an OBOC peptide library composed of natural amino acids, the sequencing protocols of the automatic sequencer are well developed and standardized. However, structure determination of peptides composed of unnatural a-amino acids requires modification of the standard sequencing program.32 For peptides composed of non-a-amino acids, one can use an encoding strategy or mass spectrometry if a cleavable linker is employed. In this chapter, we shall focus on the new sequencing method we have developed for unnatural a-amino acids. [Pg.317]

Furthermore, computers have now become a much more "rich" medium than paper ever was. Within the last 10 years of development of the Graphical User Interface (GUI), the technology has evolved from a mere "what you see is what you get" (WYSIWYG) concept into an intelligent and multimedia-based environment. Today s computer systems can replace papers in the streamlined operation and incorporate a much more functional and intuitive way of describing process activities and outputs. A rapid development of standard systems interfaces, including Web technology, has enabled systems to contain more automatic updates and much more intuitive information access methods than the paper-based medium ever could. [Pg.18]

The Supplement B (reference) contains a description of the process to render an automatic construction of mathematical models with the application of electronic computer. The research work of the Institute of the applied mathematics of The Academy of Sciences ( Ukraine) was assumed as a basis for the Supplement. The prepared mathematical model provides the possibility to spare strength and to save money, usually spent for the development of the mathematical models of each separate enterprise. The model provides the possibility to execute the works standard forms and records for the non-destructive inspection in complete correspondence with the requirements of the Standard. [Pg.26]

Specialized equipment for industrial measurements and automatic control have been developed (18) (see Process control). In general, the pH of an industrial process need not be controlled with great accuracy. Consequendy, frequent standardization of the cell assembly may be uimecessary. On the other hand, the ambient conditions, eg, temperature and humidity, under which the industrial control measurements are made, may be such that the pH meter must be much more robust than those intended for laboratory use. To avoid costiy downtime for repairs, pH instmments may be constmcted of modular units, permitting rapid removal and replacement of a defective subssembly. [Pg.468]

To develop a safe design, it is necessary to first design and specify all equipment and systems in accordance with applicable codes and standards. Once the system is designed, a process safety shutdown system is specified to assure that potential hazards that can be detected by measuring process upsets are detected, and that appropriate safety actions (normally an automatic shutdown) are initiated. A hazards analysis is then normally undertaken to identify and mitigate potential hazards that could lead to fire, explosion, pollution, or injury to personnel and that cannot be detected as process upsets. Finally, a system of safety management is implemented to assure the system is operated and maintained in a safe manner by personnel who have received adequate training. [Pg.386]

A factor which previously limited installation of automatic corrosion monitoring systems was the cost of cabling between sensors and control room instrumentation-this was particularly relevant to the electrical resistance (ER) systems. Developments to overcome this have included transmitter units at the probe location providing the standard 4-20 mA output (allowing use of standard cable) for onward transmission to data systems or the use of radio linkage which has been successfully used for other process-plant instrumentation. [Pg.1129]

National capacity variance When developing a treatment standard, U.S. EPA examines the available treatment capacity to determine whether it is sufficient to handle current and future waste management needs. If U.S. EPA determines that nationally there is not enough capacity to treat a waste, it can automatically extend the effective date of the waste s treatment standard. Such an extension to the effective date is intended to give the waste treatment industry more time to develop the capacity to handle the waste. Wastes under a national capacity variance can be disposed of, without meeting the treatment standards, in landfills and surface impoundments that meet minimum technical requirements (e.g., liners, leachate collection and removal systems, and leak detection systems). [Pg.454]

In contrast to our preferred standard mode in this book, we do not develop a Matlab function for the task of numerical integration of the differential equations pertinent to chemical kinetics. While it would be fairly easy to develop basic functions that work reliably and efficiently with most mechanisms, it was decided not to include such functions since Matlab, in its basic edition, supplies a good suite of fully fledged ODE solvers. ODE solvers play a very important role in many applications outside chemistry and thus high level routines are readily available. An important aspect for fast computation is the automatic adjustment of the step-size, depending on the required accuracy. Also, it is important to differentiate between stiff and non-stiff problems. Proper discussion of the difference between the two is clearly outside the scope of this book, however, we indicate the stiffness of problems in a series of examples discussed later. So, instead of developing our own ODE solver in Matlab, we will learn how to use the routines supplied by Matlab. This will be done in a quite extensive series of examples. [Pg.82]

Sample preparation is of paramount importance in an analytical laboratory, but automatic sample preparation has had relatively Httle attention. Developments have often simply been mechanized versions of standard analytical procedures. When an analysis is automated it is essential to look at the overall analytical problem—it is important initially to determine whether or not sample preparation is required (each analytical step which is automated compHcates the instrumental requirements, making it increasingly difficult to obtain rehable repeatable analytical results). [Pg.103]

In our development studies, Endeavor (5 mL) and Buchi (IL) reactor systems were used to screen catalysts and to evaluate the impurity profile under various process conditions. Elydrogenation kinetic studies were carried out using a 100 mL EZ-seal autoclave with an automatic data acquisition system to monitor the hydrogen uptake and to collect samples for HPLC analysis. Standard conditions of 5 g of aldehyde in 25 mL ethyl acetate and 25 mL methanol with 0.5 g of 5%Pd/C Engelhard Escat 142 were used in this investigation. For the Schiff s base formation and subsequent hydrogenation, inline FTTR was used to follow the kinetics of the Schiff s base formation under different conditions. Tables 1 and 2 show the changes in the substrate concentration under different conditions. Both experiments were carried without any limitations of gas-liquid mass transfer. [Pg.25]


See other pages where Development, automatic standard is mentioned: [Pg.206]    [Pg.1280]    [Pg.174]    [Pg.839]    [Pg.121]    [Pg.200]    [Pg.101]    [Pg.181]    [Pg.413]    [Pg.1761]    [Pg.1972]    [Pg.155]    [Pg.39]    [Pg.163]    [Pg.224]    [Pg.240]    [Pg.766]    [Pg.350]    [Pg.369]    [Pg.871]    [Pg.56]    [Pg.221]    [Pg.225]    [Pg.97]    [Pg.295]    [Pg.17]    [Pg.616]    [Pg.259]    [Pg.165]    [Pg.59]    [Pg.127]    [Pg.72]    [Pg.583]    [Pg.550]    [Pg.19]    [Pg.177]    [Pg.76]    [Pg.53]    [Pg.99]    [Pg.181]    [Pg.577]   
See also in sourсe #XX -- [ Pg.68 , Pg.77 ]




SEARCH



Automatic development

Standards development

© 2024 chempedia.info