Analytical procedures standardization

Analytical Procedures. Standard methods for analysis of food-grade adipic acid are described ia the Food Chemicals Codex (see Refs, ia Table 8). Classical methods are used for assay (titration), trace metals (As, heavy metals as Pb), and total ash. Water is determined by Kad-Fisher titration of a methanol solution of the acid. Determination of color ia methanol solution (APHA, Hazen equivalent, max. 10), as well as iron and other metals, are also described elsewhere (175). Other analyses frequendy are required for resia-grade acid. For example, hydrolyzable nitrogen (NH, amides, nitriles, etc) is determined by distillation of ammonia from an alkaline solution. Reducible nitrogen (nitrates and nitroorganics) may then be determined by adding DeVarda s alloy and continuing the distillation. Hydrocarbon oil contaminants may be determined by ir analysis of halocarbon extracts of alkaline solutions of the acid. [Pg.246]

The method for chloroacetanilide soil metabolites in water determines concentrations of ethanesulfonic acid (ESA) and oxanilic acid (OXA) metabolites of alachlor, acetochlor, and metolachlor in surface water and groundwater samples by direct aqueous injection LC/MS/MS. After injection, compounds are separated by reversed-phase HPLC and introduced into the mass spectrometer with a TurboIonSpray atmospheric pressure ionization (API) interface. Using direct aqueous injection without prior SPE and/or concentration minimizes losses and greatly simplifies the analytical procedure. Standard addition experiments can be used to check for matrix effects. With multiple-reaction monitoring in the negative electrospray ionization mode, LC/MS/MS provides superior specificity and sensitivity compared with conventional liquid chromatography/mass spectrometry (LC/MS) or liquid chromatography/ultraviolet detection (LC/UV), and the need for a confirmatory method is eliminated. In summary,... [Pg.349]

Ex Analytical technique Analytical method Analytical procedure Standard operating procedure... [Pg.203]

The standard analytic procedure involves calculating the orthogonal transformation matrix T that diagonalizes the mass weighted Hessian approximation H = M 2HM 2, namely... [Pg.247]

An analytical procedure is often tested on materials of known composition. These materials may be pure substances, standard samples, or materials analyzed by some other more accurate method. Repeated determinations on a known material furnish data for both an estimate of the precision and a test for the presence of a constant error in the results. The standard deviation is found from Equation 12 (with the known composition replacing /x). A calculated value for t (Eq. 14) in excess of the appropriate value in Table 2.27 is interpreted as evidence of the presence of a constant error at the indicated level of significance. [Pg.198]

In practice, however, any improvement in the sensitivity of an acid-base titration due to an increase in k is offset by a decrease in the precision of the equivalence point volume when the buret needs to be refilled. Consequently, standard analytical procedures for acid-base titrimetry are usually written to ensure that titrations require 60-100% of the buret s volume. [Pg.313]

The ease of hydrolysis of metal alkoxides makes metal analysis a comparatively simple task. In many cases, the metal may be estimated by hydrolysis of a sample in a cmcible, and ignition to the metal oxide. Alternatively, the metal ion may be brought into solution by hydrolysis of a sample with dilute acid, followed by a standard analytical procedure for a solution of that particular metal. If the alcohol Hberated during the hydrolysis is likely to cause interference, it may be distilled from the solution by boiling. [Pg.28]

The quantity of sample required comprises two parts the volume and the statistical sample size. The sample volume is selected to permit completion of all required analytical procedures. The sample size is the necessary number of samples taken from a stream to characterize the lot. Sound statistical practices are not always feasible either physically or economically in industry because of cost or accessibiUty. In most sampling procedures, samples are taken at different levels and locations to form a composite sample. If some prior estimate of the population mean, and population standard deviation. O, are known or may be estimated, then the difference between that mean and the mean, x, in a sample of n items is given by the following ... [Pg.298]

Tar. Before the development of gas chromatography (gc) and high pressure Hquid chromatography (hplc), the quantitative analyses of tar distillate oils involved tedious high efficiency fractionation and refractionation, followed by identification or estimation of individual components by ir or uv spectroscopy. In the 1990s, the main components of the distillate fractions of coal tars are deterrnined by gc and hplc (54). The analytical procedures included in the specifications for tar bulk products are given in the relevant Standardi2ation of Tar Products Tests Committee (STPTC) (33), ISO (55), and ASTM (35) standards. [Pg.346]

The errors arising in sampling, particularly in the case of heterogeneous solids, may be the most important source of uncertainty in the subsequent analysis of the material. If we represent the standard deviation of the sampling operation (the sampling error) by ss and the standard deviation of the analytical procedures (the analytical error) by sA, then the overall standard deviation sT (the total error) is given by... [Pg.151]

In both the standard oxygen analytical procedure and the Cu/O ratio method, the primer was counted for 20 sec following a 25 sec irradiation and a 4.5 sec transfer from completion of irradiation to start of count... [Pg.367]

Whilst for the analysis of plant material for cannabinoids both GC and HPLC are commonly used, in analytical procedures the employment of GC-based methods prevails for human forensic samples. Nonetheless, the usage of HPLC becomes more and more of interest in this field especially in combination with MS [115-120]. Besides the usage of deuterated samples as internal standards Fisher et al. [121] describe the use of a dibrominated THC-COOH (see 7.5). The usage of Thermospray-MS and electrochemical detection provide good performance and can replace the still-used conventional UV detector. Another advantage in the employment of HPLC rather than GC could be the integration of SPE cartridges, which are needed for sample preparation in the HPLC-system. [Pg.31]

To validate the analytical procedure recovery experiments are performed. To this end, the CRM is spiked with a known mass of the analytes at a variety of concentration levels (at least three different levels) and the concentrations measured are compared to the expected concentrations in at least three separate experiments. The extraction step has been shown to be a critical step in the analytical procedure and it may be responsible for poor recoveries. The efficiency of this step can be assessed either by repetitive extraction of the sample or by the addition of internal standards prior to the extraction step with the assumption that the latter actually represent the behavior of the analytes of interest. [Pg.100]

Particularly for direct microanalytical techniques using <10 mg of sample for analysis, it is highly desirable to obtain quantitative information on element- and compound-specific homogeneity in the certificates for validation and quality control of measurements. As the mean concentration in a CRM is clearly material-related, the standard deviation of this mean value should represent the element s distribution in this matrix rather than differences in the analytical procedures used. [Pg.130]

A pharmacopoeial reference substance is intended for the determination of the main component of a substance or for the active ingredient of a pharmaceutical formulation which is usually present at a high proportion of the total. The reference substance is to be used as a primary standard in a specific method validated as prescribed in the ICH Guideline Validation of Analytical Procedure Methodology" (Technical Guide for the Elaboration of Monographs 1996 ICH Guideline 1997). the reproducibility of which is known. This is taken into account when the limits of acceptance (tolerance) for the substance or product are fixed (Daas and Miller 1997,1998). [Pg.185]

Users may conclude that the analytical procedure gives correct results if the difference between the analyst s experimental mean(s) (Xe) and the certified value(s) (xj is less than the combined uncertainty (is standard deviation) of the experimental and certified means (Equation. 7-1), with Se and Sc representing the estimates of the respective standard deviations. [Pg.248]

Most often studies will be accepted by regulatory authorities even if they do not contain all information. For example, a summary, the scope, a separate notice regarding the residue definition or a schematic diagram of the analytical procedure are helpful and may avoid additional questions, but they are not essential. Also, detailed specification of standard glassware or chemicals commonly used in residue analysis is less important. Finally, data about extraction efficiency or analyte stability can be offered in separate studies or statements, which are also valid for other methods. However, each method must precisely describe at the minimum ... [Pg.101]

In summary, official German analytical methods for pesticide residues are always validated in several laboratories. These inter-laboratory studies avoid the acceptance of methods which cannot readily be reproduced in further laboratories and they do improve the ruggedness of analytical procedures applied. The recently introduced calibration with standards in matrix improves the trueness of the reported recovery data. Other aspects of validation (sample processing, analyte stability, extraction efficiency) are not considered. [Pg.128]

The method using GC/MS with selected ion monitoring (SIM) in the electron ionization (El) mode can determine concentrations of alachlor, acetochlor, and metolachlor and other major corn herbicides in raw and finished surface water and groundwater samples. This GC/MS method eliminates interferences and provides similar sensitivity and superior specificity compared with conventional methods such as GC/ECD or GC/NPD, eliminating the need for a confirmatory method by collection of data on numerous ions simultaneously. If there are interferences with the quantitation ion, a confirmation ion is substituted for quantitation purposes. Deuterated analogs of each analyte may be used as internal standards, which compensate for matrix effects and allow for the correction of losses that occur during the analytical procedure. A known amount of the deuterium-labeled compound, which is an ideal internal standard because its chemical and physical properties are essentially identical with those of the unlabeled compound, is carried through the analytical procedure. SPE is required to concentrate the water samples before analysis to determine concentrations reliably at or below 0.05 qg (ppb) and to recover/extract the various analytes from the water samples into a suitable solvent for GC analysis. [Pg.349]

The analytical response generated by an immunoassay is caused by the interaction of the analyte with the antibody. Although immunoassays have greater specificity than many other analytical procedures, they are also subject to significant interference problems. Interference is defined as any alteration in the assay signal different from the signal produced by the assay under standard conditions. Specific (cross-reactivity) and nonspecific (matrix) interferences may be major sources of immunoassay error and should be controlled to the greatest extent possible. Because of their different impacts on analyses, different approaches to minimize matrix effects and antibody cross-reactivity will be discussed separately. [Pg.683]


See other pages where Analytical procedures standardization is mentioned: [Pg.244]    [Pg.244]    [Pg.301]    [Pg.107]    [Pg.39]    [Pg.486]    [Pg.388]    [Pg.367]    [Pg.369]    [Pg.368]    [Pg.377]    [Pg.536]    [Pg.298]    [Pg.954]    [Pg.265]    [Pg.583]    [Pg.193]    [Pg.528]    [Pg.565]    [Pg.65]    [Pg.518]    [Pg.445]    [Pg.229]    [Pg.328]    [Pg.329]    [Pg.44]    [Pg.10]    [Pg.125]   
See also in sourсe #XX -- [ Pg.8 , Pg.14 ]




SEARCH



Analyte standard

Analytic Procedures

Analytical Standard addition procedure

Analytical methods standard operating procedures

Analytical procedure relative standard deviation

Analytical procedures

Analytical procedures, accuracy, precision and mineral standards

Analytical standards

Standard procedure

Standardization procedure