Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Corrosion electrochemical methods

Cathodic Protection This electrochemical method of corrosion control has found wide application in the protection of carbon steel underground structures such as pipe lines and tanks from external soil corrosion. It is also widely used in water systems to protect ship hulls, offshore structures, and water-storage tanks. [Pg.2424]

Pourbaix, M., A Comparative Review of Electrochemical Methods of Assessing Corrosion and the Behavior in Practice of Corrodible Material , Corros. Sci., 5, 67 (1965)... [Pg.116]

Szkiarska-Smialowska, Z. and Janik-Czachor, M., The Analysis of Electrochemical Methods for the Determination of Characteristic Potentials of Pitting Corrosion , Corros. Set., U, 901... [Pg.207]

Corrosion of. power-station condenser tubes by polluted, waters has been particularly troubles ome in Japan anil efforts have been made to,study the problem by, electrochemical methods and by exposing model condensers at a variety of bower station sites ., Improved results have been reported, using tin. brasses , or special, tin bronzes. . Pretreatment with sodium dimethyldithiOcarbamate is reported to give protective films that will withstand the action of polluted waters , though the method would be economic only in special circurtistapcies., , , . ... [Pg.698]

Although important contributions in the use of electrical measurements in testing have been made by numerous workers it is appropriate here to refer to the work of Stern and his co-workerswho have developed the important concept of linear polarisation, which led to a rapid electrochemical method for determining corrosion rates, both in the laboratory and in plant. Pourbaix and his co-workers on the basis of a purely thermodynamic approach to corrosion constructed potential-pH diagrams for the majority of metal-HjO systems, and by means of a combined thermodynamic and kinetic approach developed a method of predicting the conditions under which a metal will (a) corrode uniformly, (b) pit, (c) passivate or (d) remain immune. Laboratory tests for crevice corrosion and pitting, in which electrochemical measurements are used, are discussed later. [Pg.1004]

A detailed and well-referenced account of electrochemical methods of testing has been written by Dean, France and Ketcham in a section of the book by Ailor. ASTM G5 1987 outlines standard methods for making potentiostatic and potentiodynamic anodic polarisation measurements and ASTM G3 1974 (R1981) gives conventions applicable to electrochemical measurements in corrosion testing. [Pg.1011]

It is evident from previous considerations (see Section 1.4) that the corrosion potential provides no information on the corrosion rate, and it is also evident that in the case of a corroding metal in which the anodic and cathodic sites are inseparable (c.f. bimetallic corrosion) it is not possible to determine by means of an ammeter. The conventional method of determining corrosion rates by mass-loss determinations is tedious and over the years attention has been directed to the possibility of using instantaneous electrochemical methods. Thus based on the Pearson derivation Schwerdtfeger, era/. have examined the logarithmic polarisation curves for potential breaks that can be used to evaluate the corrosion rate however, the method has not found general acceptance. [Pg.1011]

A Appendix—Chemical and Electrochemical Methods for the Removal of Corrosion Products... [Pg.1093]

Developments in electrochemical methods since 1976 for measurement of corrosion have been rapid. Research and development has produced several new techniques, e.g. a.c. impedance and electrochemical noise. These methods require corrosion expertise for both operation and interpretation. Industry generally prefers instrumentation that can be operated by process... [Pg.1129]

Corrosion Monitoring in Industrial Plants Using Nondestructive Testing and Electrochemical Methods , Proc. Symposium Sponsored by ASTM Committee E-7 and G-1, Montreal, Canada, May 1984, ASTM Special Technical Publication 908 Internal Corrosion Control and Monitoring in the Oil, Gas and Chemical Industries Proc. [Pg.1152]

That is, to determine the correct corrosion rates in pitting corrosion, as shown in Fig. 37, it is necessary to know the local corrosion currents on the electrode surface. The corrosion current observed is, however, obtained as the total current, which is collected by the lead wire of the electrode. From the usual electrochemical measurement, we can thus determine only an average corrosion current (i.e., the corrosion rate). Hence if we can find some way to relate such an average rate to each local corrosion rate, the local corrosion state can be determined even with the usual electrochemical method. [Pg.278]

Electrochemical methods of protection rest on different precepts (1) electroplating of the corroding metal with a thin protective layer of a more corrosion-resistant metal, (2) electrochemical oxidation of the surface or application of other types of surface layer, (3) control of polarization characteristics of the corroding metal (the position and shape of its polarization curves), and (4) control of potential of the corroding metal. [Pg.384]

MIC depends on the complex structure of corrosion products and passive films on metal surfaces as well as on the structure of the biofilm. Unfortunately, electrochemical methods have sometimes been used in complex electrolytes, such as microbiological culture media, where the characteristics and properties of passive films and MIC deposits are quite active and not fully understood. It must be kept in mind that microbial colonization of passive metals can drastically change their resistance to film breakdown by causing localized changes in the type, concentration, and thickness of anions, pH, oxygen gradients, and inhibitor levels at the metal surface during the course of a... [Pg.24]

Related pyrazole-containing compounds such as 500 and 161 (Figure 33) have shown similar properties in 1 M H2SC>4 using electrochemical methods the choice of these molecules is based on the presence of an electron cloud on the aromatic rings, the presence of 71 electrons of N = N, C = N, C = O, and C = S is expected to affect the corrosion of carbon steel <2003MI1>. [Pg.297]

In 1980 Bemhardsson et introduced an automated electrochemical method for CPT determination. The specimen is mounted as described in Section IV.2 (ii) using a stream of argon to avoid crevice corrosion and 0.02-5% sodium chloride as electrolyte. The CPT is determined by a potentiostatic test method using an instrument called the Santron CDT 400 for potential control, temperature control, and current measurements. [Pg.291]

GBech-Nielsen, in Electrochemical Methods in Corrosion Research, IV, Ed. by O. Forsen, Materials Science Forum, Vols. 111-112. Trans. Tech. Publications, Aeder-mannsdorf, Switzerland, 1992 P- 525. [Pg.312]

The present chapter begins with a brief overview of metallic corrosion and mechanisms of corrosion control. Methods of evaluating polymer performance and electrochemical characterization techniques are discussed. Barrier and adhesion aspects of corrosion control are reviewed, and some critical issues needing further study are outlined. [Pg.2]

More recent work has utilized advanced electrochemical methods to create coatings that can provide drug to the local environment as well as provide for more biocompatible and corrosion-resistant surfaces (5). In this study, the final processing of the device surface included an electrochemical method to create voids on the surface. Pharmaceuticals were loaded into the voids and released over a long period of time. The coating also enhanced corrosion resistance. There is no doubt that an understanding of surface electrochemistry, specifically at the metal-blood interface, will allow for further biomimetic enhancement. [Pg.348]

Although the nickel-containing systems have been extensively studied also by electrochemical methods [1] due to their practical importance, for example, in electrochemical power sources (Ni—Fe, Ni—Cd, Fi—NiF2 batteries), in corrosion-resistant alloys (tableware, coins, industrial instruments) as well as due to their interesting (magnetic, spectral, catalytic) properties most of the standard potentials of electrode... [Pg.499]

It is important to note that the application of electrochemical methods to the analysis of samples of art objects and archaeological artifacts allows much more than only simple identification of certain constituents advanced methods of speciation may provide information about constituents that are only slightly differing in then-composition, or for which there are only slight differences in the matrices in which the components are embedded. Further, redox speciation—and in the case of solid samples, phase speciation—can be used to derive information on production processes or corrosion (deterioration) of the components in the time that passed since their formation. The second part of this chapter is devoted to illustrating the capabilities of advanced speciation strategies. [Pg.65]

A cleaning treatment used to be applied to artifacts with a good metallic structure, whose surface is generally covered with a thin layer consisting in a mixture of corrosion products and grime, sometimes called tarnish. Cleaning aims to remove this undesired superficial layer, without (or with minimal) loss of the metallic substrate. In many cases, such a goal is more easily achieved by electrochemical methods than by mechanical and chemical methods [282]. [Pg.135]

Scientific examination of archaeological pieces and works of art is undoubtedly a necessary task for archaeometry, conservation and preservation/restoration sciences. Although essentially focused on metal corrosion problems, electrochemistry was one of the early applied scientific methodologies in such fields, in both its analytical and conservative/restorative aspects. Over the last few decades, the scope of electrochemical methods ability to interact with archaeometry, conservation and restoration has been significantly extended, by virtue of the application of new approaches—in particular, the voltammetry of microparticles. [Pg.179]

Method 2 Electrochemical Approach. The equations (12.23) developed above for the anodic and cathodic reactions in corrosion, which, when equal, lead to a steady-state corrosion current, contain two quantities that are better simplified in order to present the basis of the electrochemical method for measuring corrosion. Thus, the Galvani potential differences used there can be converted to... [Pg.149]

In spite of the fact that corrosion measurements have been made for a century and electrochemical methods used for about a half century, there is still a need for the development ofnew methods which would, e.g., predict long-term corrosion rates and that of internal corrosion that could lead to disastrous breakdowns. [Pg.153]


See other pages where Corrosion electrochemical methods is mentioned: [Pg.372]    [Pg.372]    [Pg.2438]    [Pg.123]    [Pg.14]    [Pg.199]    [Pg.210]    [Pg.230]    [Pg.945]    [Pg.978]    [Pg.1004]    [Pg.1006]    [Pg.1120]    [Pg.11]    [Pg.18]    [Pg.399]    [Pg.88]    [Pg.343]    [Pg.348]    [Pg.352]    [Pg.789]    [Pg.338]    [Pg.262]    [Pg.264]    [Pg.407]    [Pg.136]   


SEARCH



Corrosion electrochemical

Electrochemical corrosive method

Electrochemical methods

© 2024 chempedia.info