Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Storage water

Tank Shell. Another example of where thickness is set by minimums for fabricabihty but not for strength is in small-diameter tanks. For example, a water storage tank built using a steel of an allowable stress of 20,000 psi (138 mPa), 9 ft (3 m) in diameter by 21-ft (7-m) high, requires a shell thickness to resist hoop stress of only 0.023-in. (0.58-mm) thick. However, if built to API Standard 650, the shell would be fabricated at least 0.1875-in. (4.76-mm) thick. The code requires this thickness so that when fabrication, welding, and tolerances are considered, a tank of acceptable quaUty and appearance meeting the requirements of most services in most locations is provided. [Pg.316]

In the 2inc chloride cell, precipitated basic 2inc chloride is the primary anode product because of the low concentration of ammonium chloride in the cell. Water and 2inc chloride are consumed in equations 1 and 7 and must be provided in adequate amounts for the cell to discharge efficiendy. Usually more carbon is used in 2inc chloride cells than in Led an chit cells in order to increase the electrolyte absorptivity of the cathode and thus allow the use of a larger volume of electrolyte. Also, the use of a thin paper separator, which decreases internal resistance, allows less space for water storage than the thick, pasted separator constmction traditionally used in Leclanchn cells. [Pg.522]

American Water Works Association (AWWA) The association has many standards deahng with water handling and storage. A list of its publications is given in the AWWA Handbook (annually). AWWA DlOO, Standard for Steel Tanks—Standpipes, Reservoirs, and Elevated Tanks for Water Storage, contains rules for design and fabrication. [Pg.1016]

Cathodic Protection This electrochemical method of corrosion control has found wide application in the protection of carbon steel underground structures such as pipe lines and tanks from external soil corrosion. It is also widely used in water systems to protect ship hulls, offshore structures, and water-storage tanks. [Pg.2424]

Does your house have air conditioning, or a heat pump Do you have solar he,- ig, a Jacu22i bath, swimming pool, aquarium, solar heating, a roof mounted water storage tank, a well, a power assisted commode, a motorboat, a jet ski, ATV or camper Then you have even more mechanical sealed pumps. We have mechanical sealed pumps in practically all facets of our everyday life, and these pump seals last for years wii problems. [Pg.181]

Benzo(a)pyrene (PAHs) zero 0.0002 Reproductive difficulties increased risk of cancer Leaching from linings of water storage tanks and distribution lines... [Pg.19]

Initially a molten tube of plastic called the Parison is extruded through an annular die. A mould then closes round the parison and a jet of gas inflates it to take up the shape of the mould. This is illustrated in Fig. 4.21(a). Although this process is principally used for the production of bottles (for washing-up liquid, disinfectant, soft drinks, etc.) it is not restricted to small hollow articles. Domestic cold water storage tanks, large storage drums and 2(X)... [Pg.268]

Heavy-walled drums once used for lead antiknock chemicals have been used for water storage or as barbecue pits, with subsequent risk to the user from residual toxic material. Equipment from the industry cited has for many years been cleaned, cut up, and sent under supervision to steel mills for recycle to eliminate the possible misuse of scrapped containers. [Pg.90]

LESF (Figure 3.4.5-5), exemplified for the large LOCA, is compared with SELF. Event tree headings are the refueling water storage tank (RWST) a passive component, an engineered safety system (SA-1) and four elements of the containment system. Other examples of the LESF method show human error in the event tree while the criteria for system success is usually in the tan It tree analysis. [Pg.117]

The safety improvements use redundancy and diversity to prevent and mitigate lents. The safety injection system (SIS) and emergency feedwater system (EFWS) are dedicated four train systems. Containment spray and safety injection pumps take water from the in-containment water storage tank (IRWST), thus, eliminating the need to switch from an external source and provide a. semi-closed system with continuous recirculation. Emergency core coolant flows direc nto the... [Pg.217]

Thermal-Hydraulic Analysis must be extended to at least 24 hours into the accident. This study used calculations for feed-and-bleed operation with a charging pump, and with gravity teed from the refueling water storage tank (RWST),... [Pg.391]

The Westi te 4 1 oop group includes nine plants housed within ici ndenser containments. Ma lese plants havi refueling water storage tanks such that switchover to either is not needed du assumed n time or is significantly delayed. The RCPs are a We.slinghouse design. [Pg.393]

BWR - Boiling Water Reactor (GE reactor having no steam generator separate from the reacior). BWST - Borated Water Storage Tank. [Pg.460]

IRWST - In-containment refueling water storage tank. [Pg.462]

Wasser-bindung, /, combination of or with water, -bindungsvermbgen, n. water-binding power, -blase, /, bubble (Afed.) vesicle vessel for heating water water-storage cell,... [Pg.504]

Linton, K. J., Chilled Water Storage, Heating/Piping/Air Conditioning, p. 53, May (1978). [Pg.367]

Mud Drilling. The conventional drillsite includes mud pits, mud cleaning equipment, water storage, mud storage, pumps and mixing facilities. Often the reserve pit associated with the conventional mud system is as large as the leveled... [Pg.1348]

Water storage, settling wells and draw-off regulations 4/27... [Pg.15]

In designing the water storage capacity, account should be taken of the pattern of water usage for the premises and, where possible, to assess the likely frequency and duration of breakdown from the water authority mains. When dealing with domestic water storage, this is usually provided to meet a 24-hour demand. [Pg.25]

When assessing water storage the following should be... [Pg.26]

Where there is a requirement for large volumes of water, storage may be sized on quantity of usage per shift ... [Pg.26]


See other pages where Storage water is mentioned: [Pg.370]    [Pg.240]    [Pg.244]    [Pg.245]    [Pg.349]    [Pg.255]    [Pg.263]    [Pg.175]    [Pg.863]    [Pg.458]    [Pg.458]    [Pg.576]    [Pg.73]    [Pg.449]    [Pg.207]    [Pg.208]    [Pg.216]    [Pg.465]    [Pg.718]    [Pg.720]    [Pg.245]    [Pg.1347]    [Pg.15]    [Pg.23]    [Pg.25]    [Pg.25]    [Pg.25]   
See also in sourсe #XX -- [ Pg.42 ]

See also in sourсe #XX -- [ Pg.6 , Pg.7 , Pg.8 , Pg.55 ]

See also in sourсe #XX -- [ Pg.232 ]

See also in sourсe #XX -- [ Pg.293 ]

See also in sourсe #XX -- [ Pg.472 , Pg.597 , Pg.598 , Pg.599 , Pg.600 , Pg.601 , Pg.602 ]




SEARCH



© 2024 chempedia.info