Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Atomic absorption spectrometry cadmium

Cadmium and inorganic compounds of cadmium in air (atomic absorption spectrometry). Cadmium and inorganic compounds of cadmium in air (X-ray fluorescence spectroscopy). Chromium and inorganic compounds of chromium in air (atomic absorption spectrometry). Chromium and inorganic compounds of chromium in air (X-ray fluorescence spectroscopy). General methods for the gravimetric determination of respirable and total inhalable dust. Carbon disulphide in air. [Pg.377]

MDHS 10/2 Cadmium and inorganic compounds m air (atomic absorption spectrometry)... [Pg.580]

Hofmann C, Vandecasteele C, Pauwels ] (1992) New calibration method for solid sampling Zeeman atomic absorption spectrometry (SS-ZAAS) for cadmium. Fresenius J Anal Chem 342 936-940. [Pg.150]

Zhang D-Q, Li C-U, Yang L-L, Sun H-W (1998) Determination of cadmium in vegetables by derivative flame atomic absorption spectrometry with atom trapping technique. J Anal At Spectrom 13 1155-1158. [Pg.235]

Ellen G, Van Loon JW. 1990. Determination of cadmium and lead in foods by graphite furnace atomic absorption spectrometry with Zeeman background correction Test with certified reference materials. Food Addit Contam 7 265-273. [Pg.511]

Zhang Z-W, Shimbo S, Ochi N, et al. 1997. Determination of lead and cadmium in food and blood by inductively coupled plasma mass spectrometry a comparison with graphite furnace atomic absorption spectrometry. Science of the Total Environment 205(2-3) 179-187. [Pg.589]

Ho M.D., Evans G.J. Operational speciation of cadmium, copper, lead and zinc in the NIST standard reference materials 2710 and 2711 (Montana soil) by the BCR sequential extraction procedure and flame atomic absorption spectrometry. Anal Commun 1997 34 353-364. [Pg.339]

Mercury was determined after suitable digestion by the cold vapour atomic absorption method [40]. Lead was determined after digestion by a stable isotope dilution technique [41-43]. Copper, lead, cadmium, nickel, and cobalt were determined by differential pulse polarography following concentration by Chelex 100 ion-exchange resin [44,45], and also by the Freon TF extraction technique [46]. Manganese was determined by flameless atomic absorption spectrometry (FAA). [Pg.34]

In the determination of cadmium in seawater, for both operational reasons and ease of interpretation of the results it is necessary to separate particulate material from the sample immediately after collection. The dissolved trace metal remaining will usually exist in a variety of states of complexation and possibly also of oxidation. These may respond differently in the method, except where direct analysis is possible with a technique using high-energy excitation, such that there is no discrimination between different states of the metal. The only technique of this type with sufficiently low detection limits is carbon furnace atomic absorption spectrometry, which is subject to interference effects from the large and varying content of dissolved salts. [Pg.146]

Various workers have discussed the application of graphite furnace atomic absorption spectrometry to the determination of cadmium in seawater [ 115— 124],... [Pg.146]

Batley and Farrah [ 120] and Gardner and Yates [118] used ozone to decompose organic matter in samples and thus break down metal complexes prior to atomic absorption spectrometry. By this treatment, metal complexes of humic acid and EDTA were broken down in less than 2 min. These observations led Gardner and Yates [ 118 ] to propose the following method for the determination of cadmium in seawater. [Pg.146]

Lum and Callaghan [140] determined down to 2 ng/1 of cadmium directly in seawater by atomic absorption spectrometry with Zeeman correction. [Pg.151]

A Cis column loaded with sodium diethyldithiocarbamate has been used to extract copper and cadmium from seawater. Detection limits for analysis by graphite furnace atomic absorption spectrometry were 0.024 pg/1 and 0.004 xg/l, respectively [283]. [Pg.172]

Armannsson [659] has described a procedure involving dithizone extraction and flame atomic absorption spectrometry for the determination of cadmium, zinc, lead, copper, nickel, cobalt, and silver in seawater. In this procedure 500 ml of seawater taken in a plastic container is exposed to a 1000 W mercury arc lamp for 5-15 h to break down metal organic complexes. The solution is adjusted to pH 8, and 10 ml of 0.2% dithizone in chloroform added. The 10 ml of chloroform is run off and after adjustment to pH 9.5 the aqueous phase is extracted with a further 10 ml of dithizone. The combined extracts are washed with 50 ml of dilute ammonia. To the organic phases is added 50 ml of 0.2 M-hydrochloric acid. The phases are separated and the aqueous portion washed with 5 ml of chloroform. The aqueous portion is evaporated to dryness and the residue dissolved in 5 ml of 2 M hydrochloric acid (solution A). Perchloric acid (3 ml) is added to the organic portion, evaporated to dryness, and a further 2 ml of 60% perchloric acid added to ensure that all organic matter has been... [Pg.237]

Fang et al. [661] have described a flow injection system with online ion exchange preconcentration on dual columns for the determination of trace amounts of heavy metal at pg/1 and sub-pg/1 levels by flame atomic absorption spectrometry (Fig. 5.17). The degree of preconcentration ranges from a factor of 50 to 105 for different elements, at a sampling frequency of 60 samples per hour. The detection limits for copper, zinc, lead, and cadmium are 0.07, 0.03, 0.5, and 0.05 pg/1, respectively. Relative standard deviations are 1.2-3.2% at pg/1 levels. The behaviour of the various chelating exchangers used was studied with respect to their preconcentration characteristics, with special emphasis on interferences encountered in the analysis of seawater. [Pg.238]

Cabezon et al. [662] simultaneously separated copper, cadmium, and cobalt from seawater by coflotation with octadecylamine and ferric hydroxide as collectors prior to analysis of these elements by flame atomic absorption spectrometry. The substrates were dissolved in an acidified mixture of ethanol, water, and methyl isobutyl ketone to increase the sensitivity of the determination of these elements by flame atomic absorption spectrophotometry. The results were compared with those of the usual ammonium pyrrolidine dithiocarbamate/methyl isobutyl ketone extraction method. While the mean recoveries were lower, they were nevertheless considered satisfactory. [Pg.238]

Zhuang et al. [664] used palladium salts as a coprecipitation carrier for the concentration of cadmium, cobalt, and lead in seawater prior to analysis by atomic absorption spectrometry. [Pg.239]

Jin [666] used ammonium pyrrolidine dithiocarbamate and electrothermal atomic absorption spectrometry to determine lead, cadmium, copper, cobalt, tin, and molybdenum in seawater. [Pg.239]

Rodionova and Ivanov [667] used chelate extraction in the determination of copper, bismuth, lead, cadmium, and zinc in seawater. The metal complexes of diethyl and dithiophosphates are extracted in carbon tetrachloride prior to determination by atomic absorption spectrometry. [Pg.239]

Chakraborti et al. [665] determined cadmium, cobalt, copper, iron, nickel, and lead in seawater by chelation with diethyldithiocarbamate from a 500 ml sample, extraction into carbon tetrachloride, evaporation to dryness, and redissolution in nitric acid prior to determination by electrothermal atomic absorption spectrometry in amounts ranging from 10 pg (cadmium) to 250 pg (nickel). [Pg.239]

Cimadevilla et al. [691] compared wall, platform, and graphite furnace probe atomisation techniques in electrothermal atomic absorption spectrometry for the determination of ig/l levels of silver, cadmium, and lead in seawater. [Pg.240]

Chang et al. [952] used a miniature column packed with a chelating resin and an automatic online preconcentration system for electrothermal atomic absorption spectrometry to determine cadmium, cobalt, and nickel in seawater. Detection limits of 0.12,7 and 35 ng/1 were achieved for cadmium, cobalt, and nickel, respectively, with very small sample volume required (400-1800 xl). [Pg.240]

Campbell and Ottaway [672] have described a simple and rapid method for the determination of cadmium and zinc in seawater, using atomic absorption spectrometry with carbon furnace atomisation. Samples, diluted 1 + 1 with deionised water, are injected into the carbon furnace and atomised in an HGA-72 furnace atomiser under gas-stop conditions. A low atomisation temperature... [Pg.240]

Cadmium, copper, and silver have been determined by an ammonium pyrrolidine dithiocarbamate chelation, followed by a methyl isobutyl ketone extraction of the metal chelate from the aqueous phase [677], and finally followed by graphite furnace atomic absorption spectrometry. The detection limits of this technique for 1% absorption were 0.03 pmol/1 (copper), 2 nmol/1 (cadmium), and 2 nmol/1 (silver). [Pg.242]

Boyle and Edmond [679] determined copper, nickel, and cadmium in 100 ml of seawater by coprecipitation with cobalt pyrrolidine dithiocarba-mate and graphite atomiser atomic absorption spectrometry. Concentration ranges likely to be encountered and estimated analytical precisions (lcr) are l-6nmol/kg ( 0.1) for copper, 3-12nmol/kg ( 0.3) for nickel, and 0.0-1.1 nmol/kg ( 0.1) for cadmium. [Pg.243]

Brugmann et al. [680] compared three methods for the determination of copper, cadmium, lead, nickel, and zinc in North Sea and northeast Atlantic waters. Two methods consisted of atomic absorption spectroscopy but with preconcentration using either freon or methyl isobutyl ketone, and anodic stripping voltammetry was used for cadmium, copper, and lead only. Inexplicable discrepancies were found in almost all cases. The exceptions were the cadmium results by the two atomic absorption spectrometric methods, and the lead results from the freon with atomic absorption spectrometry and anodic scanning voltammetric methods. [Pg.243]

Bruland et al. [122] have shown that seawater samples collected by a variety of clean sampling techniques yielded consistent results for copper, cadmium, zinc, and nickel, which implies that representative uncontaminated samples were obtained. A dithiocarbamate extraction method coupled with atomic absorption spectrometry and flameless graphite furnace electrothermal atomisation is described which is essentially 100% quantitative for each of the four metals studied, has lower blanks and detection Emits, and yields better precision than previously published techniques. A more precise and accurate determination of these metals in seawater at their natural ng/1 concentration levels is therefore possible. Samples analysed by this procedure and by concentration on Chelex 100 showed similar results for cadmium and zinc. Both copper and nickel appeared to be inefficiently removed from seawater by Chelex 100. Comparison of the organic extraction results with other pertinent investigations showed excellent agreement. [Pg.243]

Mykytiuk et al. [184] have described a stable isotope dilution sparksource mass spectrometric method for the determination of cadmium, zinc, copper, nickel, lead, uranium, and iron in seawater, and have compared results with those obtained by graphite furnace atomic absorption spectrometry and inductively coupled plasma emission spectrometry. These workers found that to achieve the required sensitivity it was necessary to preconcentrate elements in the seawater using Chelex 100 [121] followed by evaporation of the desorbed metal concentrate onto a graphite or silver electrode for isotope dilution mass spectrometry. [Pg.287]

Gardner [6] has reported a detailed statistical study involving ten laboratories of the determination of cadmium in coastal and estuarine waters by atomic absorption spectrometry. The maximum tolerable error was defined as 0.1 ptg/1 or 20% of sample concentration, whichever is the larger. Many laboratories participating in this work did not achieve the required accuracy for the determination of cadmium in coastal and estuarine water. Failure to meet targets is attributable to both random and systematic errors. [Pg.331]

Gardner and Yates [26] developed a method for the determination of total dissolved cadmium and lead in estuarine waters. Factors leading to the choice of a method employing extraction by chelating resin, and analysis by carbon furnace atomic absorption spectrometry, are described. To ensure complete extraction of trace metals, inert complexes with humic-like material are decomposed by ozone [27]. The effect of pH on extraction by and elution from chelating resin is discussed, and details of the method were presented. These workers found that at pH 7 only 1-2 minutes treatment with ozone was needed to completely destroy complexing agents such as EDTA and humic acid in the samples. [Pg.337]

Batley [28] examined the techniques available for the in situ electrodeposition of lead and cadmium in estuary water. These included anodic stripping voltammetry at a glass carbon thin film electrode and the hanging drop mercury electrode in the presence of oxygen and in situ electrodeposition on mercury coated graphite tubes. Batley [28] found that in situ deposition of lead and cadmium on a mercury coated tube was the more versatile technique. The mercury film, deposited in the laboratory, is stable on the dried tubes which are used later for field electrodeposition. The deposited metals were then determined by electrothermal atomic absorption spectrometry, Hasle and Abdullah [29] used differential pulse anodic stripping voltammetry in speciation studies on dissolved copper, lead, and cadmium in coastal sea water. [Pg.338]

Klenke et al. [5] described a technique for extraction of humic and fulvic acids from stream sediments and outlined methods for their determination. By means of flame atomic absorption spectrometry, the levels of environmentally important heavy metals (cadmium, copper, chromium, cobalt, nickel and lead) in the fulvic and humic acid extracts were compared with those in the original sediment samples. The pattern distribution of the respective metals in the two cases showed very close agreement, suggesting that the combined extract of humic and fulvic acids could be used as an indicator of the level of heavy metal pollution in flowing waters. [Pg.283]

M. H. Arbab-Zavar, M. Chamsaz, A. Youssefi and M. Aliakbari, Electrochemical hydride generation atomic absorption spectrometry for determination of cadmium. Anal. Chim. Acta, 546(1), 2005, 126-132. [Pg.146]

M. C. Yebra and S. Cancela, Continuous ultrasound-assisted extraction of cadmium from legumes and dried fruit samples coupled with on-line preconcentration-flame atomic absorption spectrometry, Anal. Bioanal. Chem., 382(4), 2005, 1093-1098. [Pg.146]


See other pages where Atomic absorption spectrometry cadmium is mentioned: [Pg.160]    [Pg.317]    [Pg.364]    [Pg.248]    [Pg.258]    [Pg.317]    [Pg.364]    [Pg.112]    [Pg.151]    [Pg.242]    [Pg.245]    [Pg.259]   
See also in sourсe #XX -- [ Pg.365 ]




SEARCH



Absorption spectrometry

Atomic absorption spectrometry

Atomic absorption spectrometry atomizers

Cadmium absorption

Cadmium atom

© 2024 chempedia.info