Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Nonvolatile

Calculations for wide-boiling mixtures are a little more difficult to converge, especially for mixtures having very light or noncondensable components together with relatively nonvolatile components and lacking components of intermediate volatility. [Pg.124]

The problem with the fiowsheet shown in Fig. 10.5 is that the ferric chloride catalyst is carried from the reactor with the product. This is separated by washing. If a reactor design can be found that prevents the ferric chloride leaving the reactor, the effluent problems created by the washing and neutralization are avoided. Because the ferric chloride is nonvolatile, one way to do this would be to allow the heat of reaction to raise the reaction mixture to the boiling point and remove the product as a vapor, leaving the ferric chloride in the reactor. Unfortunately, if the reaction mixture is allowed to boil, there are two problems ... [Pg.285]

Evaporation processes usually separate a single component (typically water) from a nonvolatile material. As such, it is good enough in most cases to assume that the vaporization and condensation processes take place at constant temperatures. [Pg.355]

Thus, to encourage wetting, 7sl and 7lv should be made as small as possible. This is done in practice by adding a surfactant to the liquid phase. The surfactant adsorbs to both the liquid-solid and liquid-vapor interfaces, lowering those interfacial tensions. Nonvolatile surfactants do not affect 7sv appreciably (see, however. Section X-7). It might be thought that it would be sufficient merely to lower ytv and that a rather small variety of additives would suffice to meet all needs. Actually it is equally if not more important that the surfactant lower 7sL> and each solid will make its own demands. [Pg.466]

It seems appropriate to assume the applicability of equation (A2.1.63) to sufficiently dilute solutions of nonvolatile solutes and, indeed, to electrolyte species. This assumption can be validated by other experimental methods (e.g. by electrochemical measurements) and by statistical mechanical theory. [Pg.360]

The fonnation of clusters in the gas phase involves condensation of the vapour of the constituents, with the exception of the electrospray source [6], where ion-solvent clusters are produced directly from a liquid solution. For rare gas or molecular clusters, supersonic beams are used to initiate cluster fonnation. For nonvolatile materials, the vapours can be produced in one of several ways including laser vaporization, thennal evaporation and sputtering. [Pg.2388]

CAUTION. Ethers that have been stored for long periods, particularly in partly-filled bottles, frequently contain small quantities of highly explosive peroxides. The presence of peroxides may be detected either by the per-chromic acid test of qualitative inorganic analysis (addition of an acidified solution of potassium dichromate) or by the liberation of iodine from acidified potassium iodide solution (compare Section 11,47,7). The peroxides are nonvolatile and may accumulate in the flask during the distillation of the ether the residue is explosive and may detonate, when distilled, with sufficient violence to shatter the apparatus and cause serious personal injury. If peroxides are found, they must first be removed by treatment with acidified ferrous sulphate solution (Section 11,47,7) or with sodium sulphite solution or with stannous chloride solution (Section VI, 12). The common extraction solvents diethyl ether and di-tso-propyl ether are particularly prone to the formation of peroxides. [Pg.315]

The Soviet scientists have performed experiments aimed at chemical identification, and have attempted to show that the 0.3-s activity is more volatile than that of the relatively nonvolatile actinide trichlorides. This experiment does not fulfill the test of chemically separating the new element from all others, but it provides important evidence for evaluation. [Pg.158]

FIGURE 2 11 Distillation of crude oil yields a series of volatile fractions having the names indicated along wih a nonvolatile residue The number of carbon atoms that characterize the hydrocarbons in each frac tion IS approximate... [Pg.79]

Treatment of 3 5 dimethylphenol with dilute nitnc acid followed by steam distillation of the reaction mixture gave a compound A (CgH9N03 mp 66°C) in 36% yield The nonvolatile residue from the steam distillation gave a compound B (CsHpNOs mp 108°C) in 25% yield on extraction with chloroform Identify compounds A and B... [Pg.1022]

Plasticizers are relatively nonvolatile liquids which are blended with polymers to alter their properties by intrusion between polymer chains. Diisooctyl phthalate is a common plasticizer. A plasticizer must be compatible with the polymer to avoid bleeding out over long periods of time. Products containing plasticizers tend to be more flexible and workable. [Pg.1011]

Nonvolatile compounds are normally present either as solid particulates or bound to solid particulates. Samples are collected by pulling large volumes of gas through a filtering unit where the particulates are collected on glass fiber filters. [Pg.196]

In the presence of H2SO4, however, aluminum and iron form nonvolatile sulfates. These sulfates decompose back to their respective oxides when ignited to 1200 °C. As a result, the change in weight after treating with HF and H2SO4 is due only to the loss of SiF4. [Pg.258]

Liquid samples are analyzed in one of two ways. For nonvolatile liquids a suitable sample can be prepared by placing a drop of the liquid between two NaCl plates, forming a thin film that typically is less than 0.01 mm thick. Volatile liquids must be placed in a sealed cell to prevent their evaporation. [Pg.393]

Minimizing Chemical Interferences The quantitative analysis of some elements is complicated by chemical interferences occurring during atomization. The two most common chemical interferences are the formation of nonvolatile compounds containing the analyte and ionization of the analyte. One example of a chemical interference due to the formation of nonvolatile compounds is observed when P04 or AP+ is added to solutions of Ca +. In one study, for example, adding 100 ppm AP+ to a solution of 5 ppm Ca + decreased the calcium ion s absorbance from 0.50 to 0.14, whereas adding 500 ppm POp to a similar solution of Ca + decreased the absorbance from 0.50 to 0.38. These interferences were attributed to the formation of refractory particles of Ca3(P04)2 and an Al-Ca-O oxide. [Pg.419]

The concentration of phenol in a water sample is determined by separating the phenol from nonvolatile impurities by steam distillation, followed by reacting with 4-aminoantipyrine and K3Ee(CN)g at pH 7.9 to form a colored antipyrine dye. A phenol standard with a concentration of... [Pg.451]

Preparing a Volatile Sample Gas chromatography can be used to separate analytes in complex matrices. Not every sample that can potentially be analyzed by GG, however, can be injected directly into the instrument. To move through the column, the sample s constituents must be volatile. Solutes of low volatility may be retained by the column and continue to elute during the analysis of subsequent samples. Nonvolatile solutes condense on the column, degrading the column s performance. [Pg.567]

Volatile analytes can be separated from a nonvolatile matrix using any of the extraction techniques described in Ghapter 7. Fiquid-liquid extractions, in which analytes are extracted from an aqueous matrix into methylene chloride or other organic solvent, are commonly used. Solid-phase extractions also are used to remove unwanted matrix constituents. [Pg.567]

Nonvolatile analytes must be chemically converted to a volatile derivative before analysis. For example, amino acids are not sufficiently volatile to analyze directly by gas chromatography. Reacting an amino acid with 1-butanol and acetyl chloride produces an esterfied amino acid. Subsequent treatment with trifluoroacetic acid gives the amino acid s volatile N-trifluoroacetyl- -butyl ester derivative. [Pg.568]

By using a beam of fast atoms or ions incident onto a nonvolatile liquid containing a sample substance, good molecular or quasi-molecular positive and/or negative ion peaks can be observed up to about 4000-5000 Da. Ionization is mild, and, since it is normally carried out at 25-35°C, it can be used for thermally labile substances such as peptides and sugars. [Pg.22]

The main difference between field ionization (FI) and field desorption ionization (FD) lies in the manner in which the sample is examined. For FI, the substance under investigation is heated in a vacuum so as to volatilize it onto an ionization surface. In FD, the substance to be examined is placed directly onto the surface before ionization is implemented. FI is quite satisfactory for volatile, thermally stable compounds, but FD is needed for nonvolatile and/or thermally labile substances. Therefore, most FI sources are arranged to function also as FD sources, and the technique is known as FI/FD mass spectrometry. [Pg.23]

For simple FI, the substance to be mass measured is volatilized by heating it close to the emitter so that its vapor can condense onto the surface of the electrode. In this form, an FI source can be used with gas chromatography, the GC effluent being passed over the emitter. However, for nonvolatile and/or thermally labile substances, a different approach must be used. [Pg.26]

For nonvolatile or thermally labile samples, a solution of the substance to be examined is applied to the emitter electrode by means of a microsyringe outside the ion source. After evaporation of the solvent, the emitter is put into the ion source and the ionizing voltage is applied. By this means, thermally labile substances, such as peptides, sugars, nucleosides, and so on, can be examined easily and provide excellent molecular mass information. Although still FI, this last ionization is referred to specifically as field desorption (FD). A comparison of FI and FD spectra of D-glucose is shown in Figure 5.6. [Pg.26]

With arcs, intense bombardment by ions and electrons and the heat produced at the electrodes cause sample molecules to be vaporized and broken down into their constituent elements. These sources are used particularly for analysis or isotope studies when the samples involved are inorganic, nonvolatile, and thermally very stable. [Pg.39]

The advent of atmospheric-pressure ionization (API) provided a method of ionizing labile and nonvolatile substances so that they could be examined by mass spectrometry. API has become strongly linked to HPLC as a basis for ionizing the eluant on its way into the mass spectrometer, although it is also used as a stand-alone inlet for introduction of samples. API is important in thermospray, plasmaspray, and electrospray ionization (see Chapters 8 and 11). [Pg.61]

The mix of ions, formed essentially at or near ambient temperatures, is passed through a nozzle (or skimmer) into the mass spectrometer for mass analysis. Since the ions are formed in the vapor phase without having undergone significant heating, many thermally labile and normally nonvolatile substances can be examined in this way. [Pg.62]

Evaporation from a spray of charged droplets produced from a stream of liquid yields ions that can be analyzed in a mass spectrometer. Thermally labile and normally nonvolatile substances such as sugars, peptides, and proteins can be examined successfully. [Pg.63]

The efficiency of separation of solvent from solute varies with their nature and the rate of flow of liquid from the HPLC into the interface. Volatile solvents like hexane can be evaporated quickly and tend not to form large clusters, and therefore rates of flow of about 1 ml/min can be accepted from the HPLC apparatus. For less-volatile solvents like water, evaporation is slower, clusters are less easily broken down, and maximum flow rates are about 0.1-0.5 ml/min. Because separation of solvent from solute depends on relative volatilities and rates of diffusion, the greater the molecular mass difference between them, the better is the efficiency of separation. Generally, HPLC is used for substances that are nonvolatile or are thermally labile, as they would otherwise be analyzed by the practically simpler GC method the nonvolatile substances usually have molecular masses considerably larger than those of commonly used HPLC solvents, so separation is good. [Pg.79]

Liquid chromatography is a separation method that is often applied to nonvolatile, thermally labile materials such as peptides, and, if their mass spectra are required after the separation step, then a mild method of ionization is needed. Since FAB/LSIMS is mild and works with a liquid matrix, it is not surprising that attempts were made to utilize this ionization source as both an inlet... [Pg.81]

Fundamentally, introduction of a gaseous sample is the easiest option for ICP/MS because all of the sample can be passed efficiently along the inlet tube and into the center of the flame. Unfortunately, gases are mainly confined to low-molecular-mass compounds, and many of the samples that need to be examined cannot be vaporized easily. Nevertheless, there are some key analyses that are carried out in this fashion the major one i.s the generation of volatile hydrides. Other methods for volatiles are discussed below. An important method of analysis uses lasers to vaporize nonvolatile samples such as bone or ceramics. With a laser, ablated (vaporized) sample material is swept into the plasma flame before it can condense out again. Similarly, electrically heated filaments or ovens are also used to volatilize solids, the vapor of which is then swept by argon makeup gas into the plasma torch. However, for convenience, the methods of introducing solid samples are discussed fully in Part C (Chapter 17). [Pg.98]

A number of elements form volatile hydrides, as shown in the table. Some elements form very unstable hydrides, and these have too transient an existence to exist long enough for analysis. Many elements do not form stable hydrides or do not form them at all. Some elements, such as sodium or calcium, form stable but very nonvolatile solid hydrides. The volatile hydrides listed in the table are gaseous and sufficiently stable to allow analysis, particularly as the hydrides are swept into the plasma flame within a few seconds of being produced. In the flame, the hydrides are decomposed into ions of their constituent elements. [Pg.99]


See other pages where Nonvolatile is mentioned: [Pg.295]    [Pg.258]    [Pg.373]    [Pg.466]    [Pg.356]    [Pg.472]    [Pg.1097]    [Pg.78]    [Pg.79]    [Pg.195]    [Pg.209]    [Pg.210]    [Pg.396]    [Pg.420]    [Pg.438]    [Pg.446]    [Pg.484]    [Pg.578]    [Pg.61]    [Pg.68]   
See also in sourсe #XX -- [ Pg.24 , Pg.134 ]

See also in sourсe #XX -- [ Pg.418 ]

See also in sourсe #XX -- [ Pg.169 , Pg.224 ]

See also in sourсe #XX -- [ Pg.253 ]

See also in sourсe #XX -- [ Pg.605 ]

See also in sourсe #XX -- [ Pg.157 , Pg.175 , Pg.181 , Pg.333 ]

See also in sourсe #XX -- [ Pg.517 ]

See also in sourсe #XX -- [ Pg.500 , Pg.501 ]

See also in sourсe #XX -- [ Pg.553 ]

See also in sourсe #XX -- [ Pg.47 ]




SEARCH



Acids nonvolatile acid

Acids nonvolatile, HPLC analysis

Acrylic acid nonvolatile

Activity of nonvolatile solutes

Analytes nonvolatile

Desorption nonvolatile molecules from surfaces

Diffusional Deposition of Nonvolatile Species in Gas Ducts

Electrolyte solutes nonvolatile

Fabrication of Nonvolatile Memory Devices Utilizing Graphene Materials Embedded in a Polymer Matrix

Field desorption nonvolatile samples

Flavor nonvolatile compounds

HPLC additives, nonvolatile

Hydrocarbons nonvolatile

Inorganic yield, nonvolatile

Ionization of nonvolatiles

Lipids nonvolatile

Liquid Chromatography of Nonvolatile Acids

Nonelectrolytes nonvolatile nonelectrolyte solutions

Nonvolatile Memories Based on Nanocrystals

Nonvolatile Solutes, Boiling-Point Elevation

Nonvolatile acids

Nonvolatile components

Nonvolatile components proteins

Nonvolatile compounds

Nonvolatile compounds, determining

Nonvolatile compounds, soil

Nonvolatile constituents

Nonvolatile content

Nonvolatile degradation products

Nonvolatile fraction

Nonvolatile inhibitors

Nonvolatile liquids

Nonvolatile matter

Nonvolatile memory

Nonvolatile memory devices

Nonvolatile nitrosamines

Nonvolatile nonelectrolyte solutions

Nonvolatile nonelectrolyte solutions colligative properties

Nonvolatile nonelectrolyte solutions, colligative

Nonvolatile organic

Nonvolatile organic compounds

Nonvolatile plasticizers

Nonvolatile precursors

Nonvolatile precursors, flavor

Nonvolatile precursors, flavor generation

Nonvolatile precursors, volatile controlled release from

Nonvolatile residue

Nonvolatile salts

Nonvolatile semiconductor memory

Nonvolatile solute

Nonvolatile solutes in water

Nonvolatile solutes, activities

Nonvolatile solutes, phase equilibrium

Nonvolatile substance

Nonvolatile, flavor generation

Ocean water, nonvolatile hydrocarbons

Phase Equilibrium in Solutions Nonvolatile Solutes

Pheromones nonvolatile

Properties of Nonvolatile Nonelectrolyte Solutions

Reactant nonvolatile liquid

Semivolatile and Nonvolatile Hydrocarbons

Solution nonvolatile

Taste Compounds (Nonvolatiles)

The Activities of Nonvolatile Solutes

Their nonvolatile natures

Tobacco smoke, nonvolatile nitrosamines

Tracers nonvolatile

Transfer of Nonvolatile Compounds

Vapor pressure nonvolatile

Vapor pressure nonvolatile solute

© 2024 chempedia.info