Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

MALDI mass spectrometry atmospheric pressure

DGE a AC AMS APCI API AP-MALDI APPI ASAP BIRD c CAD CE CF CF-FAB Cl CID cw CZE Da DAPCI DART DC DE DESI DIOS DTIMS EC ECD El ELDI EM ESI ETD eV f FAB FAIMS FD FI FT FTICR two-dimensional gel electrophoresis atto, 10 18 alternating current accelerator mass spectrometry atmospheric pressure chemical ionization atmospheric pressure ionization atmospheric pressure matrix-assisted laser desorption/ionization atmospheric pressure photoionization atmospheric-pressure solids analysis probe blackbody infrared radiative dissociation centi, 10-2 collision-activated dissociation capillary electrophoresis continuous flow continuous flow fast atom bombardment chemical ionization collision-induced dissociation continuous wave capillary zone electrophoresis dalton desorption atmospheric pressure chemical ionization direct analysis in real time direct current delayed extraction desorption electrospray ionization desorption/ionization on silicon drift tube ion mobility spectrometry electrochromatography electron capture dissociation electron ionization electrospray-assisted laser desorption/ionization electron multiplier electrospray ionization electron transfer dissociation electron volt femto, 1CT15 fast atom bombardment field asymmetric waveform ion mobility spectrometry field desorption field ionization Fourier transform Fourier transform ion cyclotron resonance... [Pg.11]

Atmospheric pressure chemical ionization Atmospheric pressure infrared MALDI mass spectrometry... [Pg.400]

The ionization methods reported for IMS included MALDI [41,76-80], Secondary Ion Mass Spectrometry (SIMS) [19, 81-86], Matrix-enhanced (ME)-SIMS [87, 88], Desorption Electrospray Ionization (DESI) [89-99], Nanostructure Initiator Mass Spectrometry (NIMS) [100-102], Atmospheric Pressure Infrared MALDI Mass Spectrometry (AP-IR-MALDI-MS) [103], Laser Ablation-inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS) [104-106], Laser Desorption Postionization (LDPI) [107], Laser Ablation Electrospray Ionization Mass Spectrometry (LAESI) [108, 109], and Surface-assisted Laser Desorption/ioniza-tion Mass Spectrometry (SALDI) [110-112], Another method was called probe electrospray ionization (PESI) that was used for both liquid solution and the direct sampling on wet samples. [Pg.405]

Li Y, Shrestha B, Vertes A (2007) Atmospheric pressure molecular imaging by infrared MALDI mass spectrometry. Anal Chem 79 523-532. doi 10.1021/ac061577n... [Pg.419]

Wei, H. Nolkrantz, K. Powell, D.H. Woods, J.H. Ko, M.-C. Kennedy, R.T. Electrospray Sample Deposition for Matrix-Assisted Laser Desorption/lonization (MALDI) and Atmospheric Pressure MALDI Mass Spectrometry With Attomole Detection Limits, Rapid Commun. Mass Spectrom. 18, 1193-1200 (2004). [Pg.537]

Doroshenko, V.M. Laiko, V.V. Taranenko, N.I. Berkout, V.D. Lee, H.S. Recent developments in atmospheric pressure MALDI mass spectrometry. Int. J. Mass Spectwm. [Pg.437]

All methods for the generation of ions for mass spectrometry described up to this point require the analyte for ionization to be presented either directly under high vacuum (El, Cl, FI, FD) or contained in a sort of solution from which ions are to be extracted into or generated in the gas phase (FAB, LDI, MALDI). Even the atmospheric pressure ionization techniques employ processes that create ions from dilute (solid) solutions of the sample (ESI, APCI, APPI, AP-MALDI). This chapter deals with the manifold methods and interfaces which are allowing to overcome these limitations, and which have developed at a breathtaking pace within the short time since the publication of the first edition of this book. [Pg.621]

When mass spectrometry was first used as a routine analytical tool, El was the only commercial ion source. As needs have increased, more ionization methods have appeared. Many different types of ionization source have been described, and several of these have been produced commercially. The present situation is such that there is now only a limited range of ion sources. For vacuum ion sources, El is still widely used, frequently in conjunction with Cl. For atmospheric pressure ion sources, the most frequently used are ES, APCI, MALDI (lasers), and plasma torches. [Pg.282]

The mass spectrometer is a mass-flow sensitive device, which means that the signal is proportional to the mass flow dm/dl of the analyte, i.e. the concentration times the flow-rate. It is only now possible to realise the high (theoretically unlimited) mass range and the high-sensitivity multichannel recording capabilities that were anticipated many years ago. Of considerable interest to the problem of polymer/additive deformulation are some of the latest developments in mass spectrometry, namely atmospheric pressure ionisation (API), and the revival of time-of-flight spectrometers (allowing GC-ToFMS, MALDI-ToFMS, etc.). [Pg.351]

Fast atom bombardment (FAB) Plasma desorption (PD) Liquid secondary-ion mass spectrometry (LSIMS) Thermospray (TSP)/plasmaspray (PSP) Electrohydrodynamic ionisation (EHI) Multiphoton ionisation (MPI) Atmospheric pressure chemical ionisation (APCI) Electrospray ionisation (ESI) Ion spray (ISP) Matrix-assisted laser desorption/ionisation (MALDI) Atmospheric pressure photoionisation (APPI) Triple quadrupole (QQQ) Four sector (EBEB) Hybrid (EBQQ) Hybrid (EB-ToF, Q-ToF) Tandem ToF-ToF Photomultiplier... [Pg.352]

In principle, mass spectrometry is not suitable to differentiate enantiomers. However, mass spectrometry is able to distinguish between diastereomers and has been applied to stereochemical problems in different areas of chemistry. In the field of chiral cluster chemistry, mass spectrometry, sometimes in combination with chiral chromatography, has been extensively applied to studies of proton- and metal-bound clusters, self-recognition processes, cyclodextrin and crown ethers inclusion complexes, carbohydrate complexes, and others. Several excellent reviews on this topic are nowadays available. A survey of the most relevant examples will be given in this section. Most of the studies was based on ion abundance analysis, often coupled with MIKE and CID ion fragmentation on MS " and FT-ICR mass spectrometric instruments, using Cl, MALDI, FAB, and ESI, and atmospheric pressure ionization (API) methods. [Pg.196]

Nowadays, ESI is the leading member of the group of atmospheric pressure ionization (API) methods and the method of choice for liquid chromatography-mass spectrometry coupling (LC-MS, Chap. 12). [10-13] Currently, ESI and MALDI (Chap. 10) are the most commonly employed ionization methods and they opened doors to the widespread biological and biomedical application of mass spectrometry. [5,10,11,13-17] Moreover, ESI serves well for the analysis of ionic metal complexes [18,19] and other inorganic analytes. [20-22]... [Pg.441]

A striking feature of the ILs is their low vapor pressure. This, on the other hand, is a factor hampering their investigation by MS. For example, a technique like electron impact (El) MS, based on thermal evaporation of the sample prior to ionization of the vaporized analyte by collision with an electron beam, has only rarely been applied for the analysis of this class of compounds. In contrast, nonthermal ionization methods, like fast atom bombardment (FAB), secondary ion mass spectrometry (SIMS), atmospheric pressure chemical ionization (APCI), ESI, and MALDI suit better for this purpose. Measurement on the atomic level after burning the sample in a hot plasma (up to 8000°C), as realized in inductively coupled plasma (ICP) MS, has up to now only rarely been applied in the field of IE (characterization of gold particles dissolved in IE [1]). This method will potentially attract more interest in the future, especially, when the coupling of this method with chromatographic separations becomes a routine method. [Pg.373]

C. Fenselau, MALDI MS and Strategies for Protein Analysis, Anal. Chem. 1997,69, 661 A R. W. Nelson, D. Nedelkov, and K. A. Tubbs, Biomolecular Interaction Analysis Mass Spectrometery, AnaL Chem. 2000, 72, 405A J. J. Thomas, R. Bakhtiar, and G. Siuzdak, Mass Spectrometry in Viral Proteomics, Acc. Chem. Res. 2000,33, 179 A. P. Snyder, Interpreting Protein Mass Spectra (Washington, DC American Chemical Society, 2000) S. C. Moyer and R. J. Cotter, Atmospheric Pressure MALDI, Anal. Chem. 2002, 74, 469A. [Pg.679]

Kenny, D., Snel, M., Brown, J., Bateman, B., Coleman, J., Petrie, J. R., Laidlaw, H., and Ashford, M. (2005). Evaluation of a new aerosol matrix deposition method for atmospheric pressure and vacuum MALDI ion imaging. In Proceedings of the 53rd ASMS Conference on Mass Spectrometry and Allied Topics, San Antonio, TX. [Pg.380]

Technological advances of ion-trap mass spectrometers are the ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) and the recently released technique, the Orbitrap Fourier transform mass spectrometry (Hu et al., 2005), which enable the determination of molecular formulae with a high mass resolution and mass accuracy in mixtures. Today these ion-trap mass spectrometers are most frequently coupled with atmospheric pressure ionization (API) techniques such as electrospray ionization (ESI) (e.g., Fievre et al., 1997 Qian et al., 2001 Kujawinski et al., 2002 Llewelyn et al., 2002 Stenson et al., 2002,2003 Fard et al., 2003) or matrix-assisted laser desorption/ionization (MALDI) (e.g., Solouki et al.,... [Pg.547]

Strege summarized the technique of high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI-MS) in dereplication of natural products. In contrast to earlier electron impact ionization (El), ESI technique is applicable to virtually any ion in solution with a soft ionization process. A comparison of ESI with fast atom bombardment (FAB), matrix assisted laser desorption ionization (MALDI), atmospheric pressure chemical ionization (APCI) and other techniques demonstrates its superior sensitivity, compatibility and reliability when coupled with HPLC [51]. [Pg.659]

A variety of MS formats are widely accepted and applied in the pharmaceutical industry. The specific MS application is often defined by the sample introduction technique. The pharmaceutical applications highlighted in this article feature two types of sample introduction techniques dynamic and static. Dynamic sample introduction involves the use of high-performance liquid chromatography (HPLC) on-line with MS. The resulting liquid chromatography/mass spectrometry (LC/MS) format provides unique and enabling capabilities for pharmaceutical analysis. The electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) modes are the most widely used. Static sample introduction techniques primarily use matrix-assisted laser desorption/ionization (MALDI). ... [Pg.3419]

S.C. Moyer, R.J. Cotter, A.S. Woods, Fragmentation of phosphopeptides by atmospheric-pressure MALDI and ESI ion trap mass spectrometry, J. Am. Soc. Mass Spectrom., 13(2002)274. [Pg.539]


See other pages where MALDI mass spectrometry atmospheric pressure is mentioned: [Pg.177]    [Pg.59]    [Pg.301]    [Pg.162]    [Pg.60]    [Pg.49]    [Pg.150]    [Pg.875]    [Pg.959]    [Pg.112]    [Pg.257]    [Pg.94]    [Pg.122]    [Pg.4]    [Pg.158]    [Pg.53]    [Pg.50]    [Pg.199]    [Pg.276]    [Pg.49]    [Pg.49]    [Pg.378]    [Pg.55]    [Pg.86]    [Pg.186]   
See also in sourсe #XX -- [ Pg.31 ]




SEARCH



Atmospheric mass

Atmospheric pressure MALDI

MALDI

MALDI -mass spectrometry

MALDI spectrometry

Mass atmospheric pressure

Mass spectrometry atmospheric pressure

© 2024 chempedia.info