Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Implementation kit

ZytoDof2C CISH Implementation Kit (C-3044-40, ZytoVision GmbH, Germany) (see Note 10). [Pg.343]

ZytoVision ZytoDot2C GISH Implementation Kit contains all necessary BISH detection reagents for the detection of DIG-and DNP-labeled DNA probes on formalin-fixed tissue sections. The probes can be purchased from ZytoVision or other vendors. [Pg.350]

National Legislation Implementation Kit for the Chemical Weapons Convention ... [Pg.389]

As defined in Article 11(7) of the Convention. The use of riot control agents as a method of warfare is prohibited by Article 1(5) of the Convention. Such prohibition is criminalized in provision 6.5 of this Implementation Kit. It is also recalled that pursuant to Article III of the Convention, Each State Party shall submit to the Organization, not later than 30 days after this Convention enters into force for it, [... ] declarations [...] (e) With respect to riot control agents [...(.This declaration shall be updated not later than 30 days after any change becomes effective. ... [Pg.390]

As defined by Article 11(8) of the Convention. Under Article III(l)(c), and Article 1(4) of the Convention States Parties must declare and destroy any chemical weapons production facilities they own or possess, or that are located under their jurisdiction or control. These provisions are implemented in provisions 5.1 and 5.3 of this Implementation Kit. To prevent proliferation of chemical weapons. Article V(5) of the Convention also prohibits construction of any new chemical production facilities and modification of any existing facilities for the purpose of chemical weapons production. Such prohibition is criminalized in provision 6.6 of this Implementation Kit. [Pg.390]

It can be noted that these purposes are more restrictive than the purposes not prohibited as defined by provision 1.4 of this Implementation Kit, as far as Schedule 1 chemicals are concerned. [Pg.392]

Vor dem Sprung in die Produktion, Chemie Produktion, December 2002 Prognoses on speed of implementation PAMIRmarket study industry s demands numbering-up risks expert opinions Clariant pigment micro-reactor production smallness not an end in itself general advantages of micro flow industrial process development and optimization share of reactions suited for micro reactors hybrid approach standardized interfaces start of industrial mass production of micro reactors unit construction kit [208],... [Pg.86]

Interview with Worz/BASF in a special on heat exchangers giving expert opinion on compact heat exchangers, feasibility and problems of large-scale implementation of micro reactors measuring tool for process optimization exotic status. scale-up unit-construction kit industrial implementation in 5 years [216],... [Pg.87]

Recent studies, including the use of Microtox and ToxAlert test kits [55,56], were carried out for the determination of the toxicity of some non-ionic surfactants and other compounds (aromatic hydrocarbons, endocrine disruptors) before implementation on raw and treated wastewater, followed by the identification and quantification of polar organic cytotoxic substances for samples with more than 20% inhibition. Furthermore, the study of their contribution to the total toxicity was obtained using sequential solid-phase extraction (SSPE) before liquid chromatography-mass spectrometry (LC-MS) detection. This combined procedure allows one to focus only on samples containing toxic substances. [Pg.263]

For component-based development. How to precisely define interfaces independent of implementation, how to construct the component kit architecture and the component connectors, and how to ensure that a component conforms to the connectors. [Pg.19]

Requirements specification Describes what is required of software without reference to how it is implemented. This spec is mandatory for a major component or complete system. It may be approached differently when the complete system is created by rapidly plugging kit components together.8... [Pg.36]

The starting point for describing an architecture is to define the kinds of elements that constitute it. At the simplest level, interfaces and implementations are the elements of architecture. Beyond that, concrete implemented elements—specific kinds of buffers, synchronization primitives, coordinators, kits of parts to be assembled—can be specified as types or interfaces more-abstract ones—design patterns, patterns of connectors and components—can be described using model frameworks. It is even possible for certain architectural qualities to be quantified, in a parameterized form, on the framework level. After these elements have been defined, the architecture itself can be described using these as primitives. ... [Pg.515]

The motivation of that effort is to improve spatial resolution, spectral resolution, measurement accuracy and sensitivity. Also of great interest is the implementation of single shot multiplex spectroscopy for turbulent combustion diagnostics. The CARS spectrometer consists in a portable, lightweight source assembly developed jointly with Quantel and in detection kits which can be adapted to various experimental problems. The source assembly comprises a frequency-doubled yag laser and a tunable dye laser space is provided on the optical table for various beam handling and combining optics ( 1 ). ... [Pg.311]

This has particular limiting effects for sample preparation because of the detailed specifications given for equipment and chemicals approved for the sample preparation kit. The items of the sample preparation kit and not their purpose have been specified in detail. It turned out that some items, originally approved on the list, where not available on the market, except if custom produced for the OPCW. Because of these detailed specifications, developments in the area of sample preparations cannot easily be applied to on-site analysis. As a result, any change to sample preparation procedures that require an additional item of equipment, or more so an additional chemical, such as a different solvent (i.e. for sample clean up), cannot be implemented until the list of approved equipment is amended. [Pg.17]

The analysis scheme implemented at the Cos Cob site used three sets of tools hand-held test kits, an on-site mobile laboratory equipped with gas chromatograph/ electron capture detector (GC/ECD) and X-ray fluorescence (XRF), and an off-site laboratory with rapid turnaround capabilities (<48 h for virtually all analyses). By implementing all of these tools at the same time, the project eliminated the need for multiple sampling events and allowed the team to perform additional real-time sampling, enabling the team to delineate the extent of potential hot spots quickly. [Pg.346]

Validation of testing methods always involves a balance between costs, risks and the technical capabilities of a given laboratory (NBN-EN-ISO-CEI 17025, 1999). Laboratory administrators must establish minimum quality requirements before starting the process of validation and implementation, or before starting the whole development process. Procedures of validation for a small laboratory could not be the same as for commercial validation of a new method, whether or not new kits from a manufacturer are used. There are many cases in which the range and uncertainty of the test result values can only be given in a simplified way due to lack of information. [Pg.156]

Various categories of candidate methods may be considered. New methods described in the scientific literature may require in-house development. Commercial kit methods, on the other hand, are ready for implementation in the laboratory, often in a closed analytical system on a dedicated instrument. When reviewing prospective methods, attention should be given to the following ... [Pg.354]

When preparing a method comparison study, the analytical methods to be studied should be established in the laboratory according to written protocols and stable in routine performance. Reagents are commonly supplied as ready-made analytical kits, perhaps implemented on a dedicated analytical instrument open or closed system). The technologists performing the study should be trained in the procedures and associated instrumentation. Further, it is important that an internal quality control system is in place to ensure that the methods being compared are running in the in-control state. [Pg.371]

Software Development Kit (SDK) is a set of development tools that provide access to certain internal functions of a software. These functions can be implemented in another program. An SDK usually includes an API. [Pg.357]


See other pages where Implementation kit is mentioned: [Pg.1]    [Pg.389]    [Pg.391]    [Pg.393]    [Pg.395]    [Pg.397]    [Pg.399]    [Pg.1]    [Pg.389]    [Pg.391]    [Pg.393]    [Pg.395]    [Pg.397]    [Pg.399]    [Pg.187]    [Pg.120]    [Pg.140]    [Pg.426]    [Pg.66]    [Pg.479]    [Pg.237]    [Pg.163]    [Pg.167]    [Pg.151]    [Pg.113]    [Pg.5]    [Pg.172]    [Pg.581]    [Pg.942]    [Pg.448]    [Pg.538]    [Pg.87]    [Pg.236]    [Pg.196]    [Pg.18]    [Pg.121]    [Pg.662]   


SEARCH



Kitting

© 2024 chempedia.info