Detection flame emission

The section on Spectroscopy has been retained but with some revisions and expansion. The section includes ultraviolet-visible spectroscopy, fluorescence, infrared and Raman spectroscopy, and X-ray spectrometry. Detection limits are listed for the elements when using flame emission, flame atomic absorption, electrothermal atomic absorption, argon induction coupled plasma, and flame atomic fluorescence. Nuclear magnetic resonance embraces tables for the nuclear properties of the elements, proton chemical shifts and coupling constants, and similar material for carbon-13, boron-11, nitrogen-15, fluorine-19, silicon-19, and phosphoms-31. [Pg.1284]

Choice of Atomization and Excitation Source Except for the alkali metals, detection limits when using an ICP are significantly better than those obtained with flame emission (Table 10.14). Plasmas also are subject to fewer spectral and chemical interferences. For these reasons a plasma emission source is usually the better choice. [Pg.437]

Oxygen and nitrogen also are deterrnined by conductivity or chromatographic techniques following a hot vacuum extraction or inert-gas fusion of hafnium with a noble metal (25,26). Nitrogen also may be deterrnined by the Kjeldahl technique (19). Phosphoms is determined by phosphine evolution and flame-emission detection. Chloride is determined indirecdy by atomic absorption or x-ray spectroscopy, or at higher levels by a selective-ion electrode. Fluoride can be determined similarly (27,28). Uranium and U-235 have been determined by inductively coupled plasma mass spectroscopy (29). [Pg.443]

Analysis. Lithium can be detected by the strong orange-red emission of light in a flame. Emission spectroscopy allows very accurate determination of lithium and is the most commonly used analytical procedure. The red emission line at 670.8 nm is usually used for analytical determinations although the orange emission line at 610.3 nm is also strong. Numerous other methods for lithium determinations have been reviewed (49,50). [Pg.224]

Atomic Absorption/Emission Spectrometry. Atomic absorption or emission spectrometric methods are commonly used for inorganic elements in a variety of matrices. The general principles and appHcations have been reviewed (43). Flame-emission spectrometry allows detection at low levels (10 g). It has been claimed that flame methods give better reproducibiHty than electrical excitation methods, owing to better control of several variables involved in flame excitation. Detection limits for selected elements by flame-emission spectrometry given in Table 4. Inductively coupled plasma emission spectrometry may also be employed. [Pg.243]

Table 4. Elemental Detection Limits by Flame Emission Spectrometry ... Table 4. Elemental Detection Limits by Flame Emission Spectrometry ...
Na+ and K+ with a detection limit of 10 9 M. The sensor compositions exhibited wide response ranges between 10 9 and 10 5 M Na+ or K+, and, therefore, may be an alternative method to flame emission spectroscopy. The sensor is fully reversible within the dynamic range and the response time is 3 min under batch conditions. Cross sensitivity to pH is negligible in the pH range of 6.2-7.3. [Pg.82]

The most commonly used and widely marketed GC detector based on chemiluminescence is the FPD [82], This detector differs from other gas-phase chemiluminescence techniques described below in that it detects chemiluminescence occurring in a flame, rather than cold chemiluminescence. The high temperatures of the flame promote chemical reactions that form key reaction intermediates and may provide additional thermal excitation of the emitting species. Flame emissions may be used to selectively detect compounds containing sulfur, nitrogen, phosphorus, boron, antimony, and arsenic, and even halogens under special reaction conditions [83, 84], but commercial detectors normally are configured only for sulfur and phosphorus detection [85-87], In the FPD, the GC column extends... [Pg.375]

Flame emission spectrometry is used extensively for the determination of trace metals in solution and in particular the alkali and alkaline earth metals. The most notable applications are the determinations of Na, K, Ca and Mg in body fluids and other biological samples for clinical diagnosis. Simple filter instruments generally provide adequate resolution for this type of analysis. The same elements, together with B, Fe, Cu and Mn, are important constituents of soils and fertilizers and the technique is therefore also useful for the analysis of agricultural materials. Although many other trace metals can be determined in a variety of matrices, there has been a preference for the use of atomic absorption spectrometry because variations in flame temperature are much less critical and spectral interference is negligible. Detection limits for flame emission techniques are comparable to those for atomic absorption, i.e. from < 0.01 to 10 ppm (Table 8.6). Flame emission spectrometry complements atomic absorption spectrometry because it operates most effectively for elements which are easily ionized, whilst atomic absorption methods demand a minimum of ionization (Table 8.7). [Pg.319]

Atomic absorption spectrometry is one of the most widely used techniques for the determination of metals at trace levels in solution. Its popularity as compared with that of flame emission is due to its relative freedom from interferences by inter-element effects and its relative insensitivity to variations in flame temperature. Only for the routine determination of alkali and alkaline earth metals, is flame photometry usually preferred. Over sixty elements can be determined in almost any matrix by atomic absorption. Examples include heavy metals in body fluids, polluted waters, foodstuffs, soft drinks and beer, the analysis of metallurgical and geochemical samples and the determination of many metals in soils, crude oils, petroleum products and plastics. Detection limits generally lie in the range 100-0.1 ppb (Table 8.4) but these can be improved by chemical pre-concentration procedures involving solvent extraction or ion exchange. [Pg.333]

In principle, atomic fluorescence is a simpler and more versatile technique than atomic absorption, but suffers from a susceptibility to quenching effects and to background noise arising from the scattering of radiation by particles in the flame. The latter is particularly serious for refractory materials and in high-temperature flames. Detection limits for some elements are lower than by atomic absorption or flame emission measurements, e.g. elements with resonance lines around 200 nm or below, such as As, Se,... [Pg.334]

Table 8.6 Some detection limits for atomic absorption, fluorescence and flame emission methods... Table 8.6 Some detection limits for atomic absorption, fluorescence and flame emission methods...
Chromatographic methods have been applied with hydridization. Jackson et al. [98] used a commercial purge and trap apparatus fitted to a packed gas chromatographic column and flame photometric detector to achieve a O.lng detection. Purge and trap procedures followed by boiling point separations and detection by spectrophotometric methods yield detection limits in water of between 0.01 and lng. Detection of SnH emission by flame emission gives the greatest sensitivity. [Pg.422]

One often unsuspected source of error can arise from interference by the substances originating in the sample which are present in addition to the analyte, and which are collectively termed the matrix. The matrix components could enhance, diminish or have no effect on the measured reading, when present within the normal range of concentrations. Atomic absorption spectrophotometry is particularly susceptible to this type of interference, especially with electrothermal atomization. Flame AAS may also be affected by the flame emission or absorption spectrum, even using ac modulated hollow cathode lamp emission and detection (Faithfull, 1971b, 1975). [Pg.204]

The advantages of the flame emission detector (FED) have been combined with the flame ionization detector. This design features the ability to detect CO, CO2, N2O4, SO2, N2F4, HF and H2S gases which respond poorly in an FID. In addition, the system showed qualitative differences in structure attributable to different FED/FID ratios as a function of wavelength for various compounds. [Pg.274]

Other investigators used flame emission as a modified Beilstein test for the detection of halogenated hydrocarbons. In such an arrangement, a green flame was produced when halogenated hydrocarbons were burned in the presence of a copper wire. Replacement of the copper with indium improves specificity and... [Pg.274]

The FPD is a special flame emission photometer used for the detection of phosphorus and sulfur compounds. Compounds eluting from the chromatographic column are burned inside the detector body in a low temperature flame where phosphorus and sulfur form the species with characteristic emission spectra detected with a photometer. The FPD is more sensitive and more selective to phosphorus than the... [Pg.220]

Element Line, nm Table II. PMTa Flame Emission Detection UV vid.a Limits SIT vid.a SIT with scint.a Int. pot.,kVd... [Pg.47]

The photomultiplier detects both the thermal emission from the determinant and also any other atomic or molecular emission from either concomitant elements present in the sample or from the flame itself. Figure 8, for example, shows a typical section of a flame emission spectrum. While it is possible for some determinations by FES to work at a single fixed wavelength, as in flame AAS, it is advisable, at least initially, to scan the emission spectrum in the vicinity of the wavelength of interest to confirm the absence of spectral interferences. In any event, regular re-zeroing and aspiration of an appropriate standard to check for signal drift is essential. [Pg.22]


See other pages where Detection flame emission is mentioned: [Pg.226]    [Pg.376]    [Pg.378]    [Pg.166]    [Pg.307]    [Pg.541]    [Pg.206]    [Pg.111]    [Pg.376]    [Pg.378]    [Pg.307]    [Pg.349]    [Pg.354]    [Pg.358]    [Pg.165]    [Pg.46]    [Pg.634]    [Pg.55]   
See also in sourсe #XX -- [ Pg.47 ]




SEARCH



Emission detection limits, flame

Emission-detected

Emissivity flames

Flame emission elements detected using

Hydrogen flame emission detection