The comparison between the qualities and quantities obtained and those for marketable products, the refiner can estimate the capacities and the operating conditions of the various treatment units... [Pg.335]

When the adsorption capacity of a carbon unit is exceeded, there is breakthrough of the contaminant in the treated stream. Eixed beds may be operated in series to allow continuous treatment while spent or exhausted units are replaced with fresh carbon. In series operation, there are two or more units. The majority of the contaminant is removed by the first unit in the series with the downstream units acting as polishing units. When breakthrough occurs in the first or primary unit, it is replaced with fresh carbon and becomes a polishing unit while the next unit in the series takes over and becomes the primary treatment unit. An example of this round-robin operation of a three-carbon bed is shown in Eigure 2. [Pg.160]

The treatment units used for color removal are the same as those used for turbidity removal. However, the pH must be increased prior to filtration so that the metal hydroxides are removed by the filters. At low pH values, metal ions or their soluble complexes readily pass through the filters and form insoluble species in storage tanks and in the distribution system. For iron salts, it is important that the pH be greater than 6 as the oxidation of iron(II) to iron(III) occurs rapidly above this pH in the presence of dissolved oxygen or other strong oxidants (18). [Pg.278]

Lime and Lime-Soda Processes. The first softening plant in the early 1900s used the lime softening process with fill and draw units. Later, continuous-treatment units, which greatiy increased the amount of water that could be treated in a faciUty of given size, were developed. More than 1000 municipahties soften water. Most are in the Midwest and in Florida. However, concern for the adverse effect of soft water on cardiovascular disease (CVD) may limit the number of plants that introduce softening. [Pg.278]

Wastewater treatment plants are also a significant source of refinery air emissions and solid wastes. Air releases arise from fugitive emissions from the numerous tanks, ponds, and sewer system drains. Solid wastes are generated in the form of sludges from a number of the treatment units. [Pg.97]

NSF International Certification Criteria for Drinking Water Treatment Units Various papers on adsorption and other technologies for drinking and wastewater applications, http //nsf.org/consumer/dwtuconsumer.html... [Pg.333]

The investment required to set up a treatment unit complete with coalescer varies from 750 to 2,500 per cubic meter of water to be treated, depending on unit size and available space. Operating costs are low. [Pg.282]

Equalizing basin A holding basin in which variations in flow and composition of liquid are averaged. Such basins are used to provide a flow of reasonably uniform volume and composition to a treatment unit. Also called a balancing reservoir. Estuaries Bodies of water which are located at the lower end of a river and are subject to tidal fluctuations. [Pg.613]

Remediation activities at American Thermostat included the excavation and thermal treatment of over 13,000 cubic yards of soil and sediments contaminated primarily with perchloroethylene, trichloroethylene, and solvents. The soil was excavated and treated using a thermal treatment unit called the low-temperature enhanced volatilization facility (LTEVF). The performance test for the site s thermal unit had just been completed at the time of the inspection, so there was limited activity. [Pg.179]

Similarly, the Site B contractor s SSAHP provided corporate policy and procedures for permit-required confined space entry but lacked the site-specific detail necessary to describe the application of the corporate policy to procedures at the site. For example, the SSAHP did not identify specific components of the thermal treatment unit that presented confined space hazards, nor did it describe the specific circumstances or procedures that would require employee entry into these areas. In addition, the plan stated that the contractor would maintain an onsite employee confined space rescue team, but did not identify the members of this team. The SSAHP for Site F also contained a generic confined space entry program but did not identify the specific location of confined space hazards present at the site. [Pg.201]

Feeds to hydrotreatment units vary widely they could he any petroleum fraction, from naphtha to crude residues. The process is relatively simple choosing the desulfurization process depends largely on the feed type, the level of impurities present, and the extent of treatment needed to suit the market requirement. Table 3-12 shows the feed and product properties from a hydro treatment unit. ... [Pg.83]

In subjects with sedative-hypnotic dependence who underwent detoxification in an addictions treatment unit, a significant association was not found between abstinence rate and either gender or psychiatric status (Charney et al. 2000). Patients dependent on benzodiazepines reported decreased anxiety during follow-up, even though their use of these agents had decreased. [Pg.137]

The used raw materials were TiCU, oxygen, Ar and NaOH. The reaction apparatus consisted of gas purifiers, reactant preheaters, reactor, water cooler, separator and an off-gas treatment unit. The reactor was a 27 mm in ID. (32 mm in O.D.), 1430 mm in length quartz tube that was heated by a horizontal electrical furnace. A quartz rod and a ceramic rod, 6 mm... [Pg.417]

The TSDF standards also establish requirements to ensure that hazardous waste management units are closed in a manner that protects human health and the environment. The closure provisions require the facility to stop accepting waste remove all waste from management units and decontaminate all soils, structures, and equipment. Some units (i.e., land treatment units, landfills, and surface impoundments) serve as places for the final disposal of hazardous waste. These land disposal units must comply with additional postclosure requirements to ensure proper long-term unit maintenance. [Pg.450]

RCRA s TSDF standards also include provisions to protect groundwater and air resources from hazardous waste contamination. RCRA requires owners and operators of land-based units (i.e., land treatment units, landfills, surface impoundments, and waste piles) to monitor the groundwater below their TSDF for possible contamination, and clean up any discovered contamination. [Pg.450]

Figure 14.1 presents the main components of a typical in situ SVE system.910 Vertical extraction wells are installed inside the contaminated zone at appropriate distances from one another. The SVE wells are typically constructed of PVC pipe, with a screened interval, which is placed within the contaminated zone. The wells are connected to blowers or vacuum pumps, which induce a continuous airflow through the pores of the unsaturated zone. The soil surface is sometimes covered with an impermeable seal, made from high density polyethylene (HDPE) or bentonite clay for example, to prevent the vertical influx of air from the surface, which might cause short-circuiting problems, and promote horizontal gas flow through the contaminated area. The airstream, which contains the contaminant vapors, passes initially through an air-water separation unit to remove the entrained moisture and is then directed to the gas treatment unit, where the contaminants are thermally destroyed or removed by adsorption. [Pg.523]

Pilot testing is intended to simulate the physical, biological, and chemical parameters of a full-scale process therefore, the treatment unit size and the volume of waste to be processed in pilot systems greatly increase over those of bench-scale testing. As such, pilot tests are intended to bridge the gap between bench-level analyses and full-scale operation, and are intended to more accurately simulate the performance of a selected full-scale process. [Pg.603]

Treatment of wastewater generated in most industries is often achieved in many steps depending on the volume, shape, and nature of constituents of the wastewater. A typical wastewater treatment plant combines water treatment unit operations and processes to achieve different levels of treatment. They include the following. [Pg.914]


See other pages where Treatment units is mentioned: [Pg.33]    [Pg.17]    [Pg.275]    [Pg.283]    [Pg.460]    [Pg.2213]    [Pg.2217]    [Pg.2224]    [Pg.2228]    [Pg.2232]    [Pg.91]    [Pg.92]    [Pg.96]    [Pg.41]    [Pg.41]    [Pg.238]    [Pg.244]    [Pg.510]    [Pg.976]    [Pg.87]    [Pg.408]    [Pg.30]    [Pg.62]    [Pg.478]    [Pg.105]    [Pg.449]    [Pg.451]    [Pg.532]    [Pg.603]    [Pg.611]    [Pg.626]    [Pg.638]    [Pg.643]   


SEARCH



© 2024 chempedia.info