Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Timing Information

Turn on clock at one place in the program - tic. Turn off clock at another place in the program - toe. The elapsed time is displayed. [Pg.246]

Note MATLAB is case sensitive so that f(/) and T(/) are different. Obtain rows from matrix  [Pg.246]

Note the period before the asterisk. The multiplication (0 made by  [Pg.247]


The errors in the present stochastic path formalism reflect short time information rather than long time information. Short time data are easier to extract from atomically detailed simulations. We set the second moment of the errors in the trajectory - [Pg.274]

In this case, the operations within a sequence are further defined according to various criteria such as whether they involve reception or transition of information, storage of information, manual control responses, inspections, and decisions. However, some other dimensions of an operation may require particular emphasis such as whether information is transmitted electronically, by external communication etc. A type of vertical axis can still be used to represent sequential order and if required this can incorporate the same timing information as temporal OSDs. [Pg.175]

In addition to providing some control of price risk, futures and options markets are also very useful mechanisms for price discovery and for gauging market sentiment. There is a world-wide need for accurate, real-time information about the prices established through futures and options trading, that is, a need for price transparency. Exchange prices are simultaneously transmitted around the world via a network of information vendors terminal seiwices directly to clients, thereby allowing users to follow the market in real time wherever they may be. Energy futures prices are also widely reported in the financial press. These markets thus enable an open, equitable and competitive environment. [Pg.546]

Decrypt the outer layer with the public key provided by the appropriate digital timestamp authority [1], validate the timestamp contents, and read the date/time information. [Pg.212]

Although these data provided indirect evidence of iron involvement in ischaemia-reperfusion injury in kidneys and the combined administration of DFX and indomethacin had proved beneficial in actual survival experiments (Gower etal., 1989a), we still felt fhistrated by our inability to generate more direct evidence. At that time, information was just emerging that a small pool of intracellular iron was available in catalytic form as chelates... [Pg.88]

The columns of this matrix contain the time information (amplitudes at a specific frequency as a function of time) and the rows the frequency information. [Pg.565]

A different approach for recovering weathering time information from U-Th series nuclides is to interpret depth variations of radioactive disequilibria in weathering profiles by simple but realistic modelling of U-Th series nuclides during formation and evolution... [Pg.543]

The dehydrogenation reaction was generally monitored by taking samples for reversed phase H PLC analysis. Diode array detectors for H PLC were relatively new at that time and proved valuable for quickly getting structural information on products of the reaction produced under different conditions. Key reaction parameters for adduct formation, overall concentration, BSTFA, TfOH, and DDQ charges, were optimized using a thermostated HPLC autosampler to sample reactions directly for analysis. Comparison of reaction profiles provided rate and reaction time information that was used to select a more limited number of reaction conditions that were scaled up to compare yields. [Pg.109]

Before we start a simulation, choose Parameters under the Simulation pull-down menu to select the time of simulation. If we are using the XY Graph, we need to double-click its icon and edit its parameters to make the time information consistent. [Pg.240]

Upon completion of the ProteinTrawler program, the text hie contains a cumulative hst of all the protein masses that were observed upon deconvolution of the individual summed spectra. This text hie records mass, intensity, and retention time. The retention time information is held in the text hie for... [Pg.212]

The first systematic measurements of the reactions of ions with molecules in the gas phase were initiated largely by workers associated with analytical mass spectrometry.4-6 It was the rapidly expanding area of ion-molecule reactions which led to the origin of Gas-Phase Ion Chemistry as a distinct field.7 The discovery that ion-molecule equilibria in the gas phase can be determined by mass spectrometric techniques8 led to an explosion of thermochemical measurements based on determination of equilibria by a variety of techniques.9 Significantly, for the first time, information could be obtained on the thermochemistry of reactions which had solution counterparts of paramount importance such as acidities and basicities. These were obtained from proton transfer equilibria such as,... [Pg.257]

Normally, time-resolved FT-IR spectroscopy (TRS FT-IR) possesses the same data characteristics. In a typical TRS FT-IR experiment, interferograms are assembled for a specific delay time after the photolysis pulse, and the data produced are normally finer-grained in frequency than in time. This type of experiment is complementary to experiments with fine-grained time information. It is particularly useful where a wide spectral range is necessary and works reasonably well for highly reproducible events which occur on relatively long timescales (fractions of seconds) (83). It is also an appealing system for use on shorter timescales, and it has... [Pg.298]

Integrated decisions also require simultaneous decision making instead of iterative or even isolated decision making. Fulfilment of this postulation was nearly impossible to achieve in former years without real-time information technology and decision support methods. Thanks to information technology and operations research method advances, the objective to syn-... [Pg.55]

Methods of near-field, midfield and ensemble (global) imaging and real-time visualization have been developed for monitoring gas atomization of liquid metals.[327] The primary process sensors and monitors used include high-speed video and infrared imaging systems. The process monitors allowed continuous and detailed observations of the atomization process and enabled measurements of the key parameters necessary for adequate control and optimization of the process. The sensors provided the operators with real-time information on the temperature of nozzle tip, visual characteristics of atomization plume, and gas and metal flow rates. The images can be displayed in real time, offering the potential for more responsive process control. [Pg.448]

Another parameter often measured is the adjusted retention time, Ur. This is the difference between the retention time of a given component and the retention time of an unretained substance, tM, which is often air for GC and the sample solvent for HPLC. Thus, the adjusted retention time is a measure of the exact time a mixture component spends in the stationary phase. Figure 11.17 shows how this measurement is made. The most important use of this retention time information is in peak identification, or qualitative analysis. This subject will be discussed in more detail in Chapter 12. [Pg.321]

We discussed the fundamentals of mass spectrometry in Chapter 10 and infrared spectrometry in Chapter 8. The quadrupole mass spectrometer and the Fourier transform infrared spectrometer have been adapted to and used with GC equipment as detectors with great success. Gas chromatography-mass spectrometry (GC-MS) and gas chromatography-infrared spectrometry (GC-IR) are very powerful tools for qualitative analysis in GC because not only do they give retention time information, but, due to their inherent speed, they are also able to measure and record the mass spectrum or infrared (IR) spectrum of the individual sample components as they elute from the GC column. It is like taking a photograph of each component as it elutes. See Figure 12.14. Coupled with the computer banks of mass and IR spectra, a component s identity is an easy chore for such a detector. It seems the only real... [Pg.351]

In ethereal solution diazomethane can he preserved for a long time. Information about its numerous reactions (with hydrogen cyanide, acetylene, quinone, etc.) can he found in the special literature of the subject. As has already been mentioned, it is an important methylating agent, especially for phenols. With them it reacts in such a way that the two nitrogen atoms are eliminated as elementary nitrogen, and the two valencies which thus become free are occupied by H and OR. [Pg.274]

W. G. McMullan, S. Charbonneau and M. L. W. Thewalt, Simultaneous subnanosecond timing information and 2D spatial information from imaging photomultiplier tubes, Rev. Sci. Instrum. 58, 1626-1628 (1987). [Pg.415]

Operation of complete, self-contained, stationary plants has been demonstrated using PEFC, AFC, PAFC, MCFC, ITSOFC, and TSOFC technology. Demonstrations of these technologies that occurred before 1998 were addressed in previous editions of the Fuel Cell Handbook and in the literature of the period. Recent U.S. manufacturer experience with these various fuel cell technologies has produced timely information. A case in point is the 200 kW PAFC on-site plant, the PC-25, that is the first to enter the commercial market (see Figure 1-7). The plant was... [Pg.29]

Ultimately, the effectiveness of a model lies in its ability to provide usefnl and timely information to the customers, which for PAT applications are often process engineers, operators and manufacturing operations personnel. Therefore, one must also consider how best to integrate the chemometric models with the existing data handling and control system. Below are several issnes in this area that are commonly experienced in PAT projects ... [Pg.432]

To control the CCD, the anthors chose a closed-loop control strategy with in-line NIR used to measure the monomer concentrations. The closed-loop control strategy nses the NIR in-line measurement to provide close to real-time information abont the concentration of both reactants and prodncts in the reactor. One prerequisite of this control strategy is that the sampling rate be faster than the kinetics of the reaction. [Pg.519]

Both new and experienced users can take advantage of software to lead them through instrument set-up and data acquisition. Automated quantitation routines are available to calculate compound amounts in samples. These routines offer complete flexihihty to generate custom report formats. By integrating retention time information and internal or external cahhration curves can he calculated. Quantitation data can he exported to popular spreadsheet programs. [Pg.18]


See other pages where Timing Information is mentioned: [Pg.49]    [Pg.136]    [Pg.181]    [Pg.516]    [Pg.352]    [Pg.123]    [Pg.67]    [Pg.164]    [Pg.472]    [Pg.243]    [Pg.293]    [Pg.434]    [Pg.438]    [Pg.18]    [Pg.468]    [Pg.191]    [Pg.53]    [Pg.368]    [Pg.124]    [Pg.601]    [Pg.25]    [Pg.23]    [Pg.70]    [Pg.155]    [Pg.9]    [Pg.38]    [Pg.515]    [Pg.456]   


SEARCH



Early time information

Experimental Data to Provide Information over Wide Ranges of Time Scale

Information Processing Attention, Perception, Reaction Time, and Comprehension

Information storage time

Process real-time information

Reaction times, information-processing link

Real-time optical information

Real-time optical information processing

Time-domain information

Transit Time Distributions, Linear Response, and Extracting Kinetic Information from Experimental Data

© 2024 chempedia.info