Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Data producers

With these massive amounts of data produced in HTS for combinatorial libraries, tools become necessary to make it possible to navigate through these data and to extract the necessary information, to search - as is said quite often -for a needle in a haystack. [Pg.603]

Nowadays a broad range of methods is available in the field of chemoinfor-matics. These methods will have a growing impact on drug design. In particular, the discovery of new lead structures and their optimization will profit by virtual saeening [17, 66, 100-103]. The huge amounts of data produced by HTS and combinatorial chemistry enforce the use of database and data mining techniques. [Pg.616]

The developed assay was successfully applied for the arsenite and arsenate determination in contaminated waters of the gold recovery plant and in snow covers of the industrial anthropogenic sources vicinities as well. The data produced are in a good agreement with the results of independent methods atomic absorptioin and atomic emission spectrometry and capillary electrophoresis. [Pg.428]

Restraints due to artifacts may, by chance, be completely consistent with the correct structure of the molecule. However, the majority of incorrect restraints will be inconsistent with the correct structural data (i.e., the correct restraints and information from the force field). Inconsistencies in the data produce distortions in the structure and violations in some restraints. Structural consistency is often taken as the final criterion to identify problematic restraints. It is, for example, the central idea in the bound-smoothing part of distance geometry algorithms, and it is intimately related to the way distance data are usually specified The error bounds are set wide enough that all data are geometrically consistent. [Pg.264]

To demonstrate the effect in more detail a series of experiments was carried out similar to that of volume overload, but in this case, the sample mass was increased in small increments. The retention distance of the front and the back of each peak was measured at the nominal points of inflection (0.6065 of the peak height) and the curves relating the retention data produced to the mass of sample added are shown in Figure 7. In Figure 7 the change in retention time with sample load is more obvious the maximum effect was to reduce the retention time of anthracene and the minimum effect was to the overloaded solute itself, benzene. Despite the reduction in retention time, the band width of anthracene is still little effected by the overloaded benzene. There is, however, a significant increase in the width of the naphthalene peak which... [Pg.428]

Table 2.6-2 (upper) shows that a gamma prior (equation 2,6-11) updated with exponential data produces a gamma posterior (equation 2.6-12) by adding rto t andM to Becau.se the prior is derived from other than test data, ris called pseudo-time and (ppseudo-failure. The mean, E(A) and standard deviation, a, of the prior and [losierior are given by Table 2.6-2 (lower). [Pg.52]

From the point of view of systematic data analysis, it has been found that consistent results can be obtained only with burn-out data produced under stable conditions. The unstable condition leads to considerable scatter, depending on the particular setting of a valve, the size of a compressible volume, the method of preforming a steam and water mixture, and so on. These latter quantities have either been recorded with very low accuracy, or have not been recorded at all. Therefore, the unstable-conditions data appear to be of little value, except for qualitative purposes. In any case, one is usually not interested in instabilities apart from knowing how to avoid them, which is by having a hard inlet. [Pg.231]

To answer this question, we must consider the ways in which the data are acquired. An RIC is generated, post-acquisition, from consecutive full scans in which a small amount of time is spent monitoring each ion, as discussed above. The data produced in a SIM experiment are generated by monitoring only a small number of ions, thus taking advantage of the increased time spent monitoring each ion. [Pg.86]

The skill in information management is to develop communities of best practice using technologies that are accessible by both data producers and consumers. [Pg.176]

It is important that the employment of the mouse bioassay and the interpretation of its results take these factors into consideration to ensure that the data produced are as reliable as possible and that the eventual conclusions are well founded. [Pg.47]

The type of data produced in a f.a.b. experiment is affected by the pH and ionic strength of the matrix. The former may be controlled either by the addition of acids or bases, although, in practice, it is usually preferable to keep the matrix acidic. The ionic strength is partly dictated by the purity of the sample (many biological compounds are still contaminated with salts, even after extensive purification) and partly by exogenous additives. Three additives are especially useful for carbohydrate work. They are as follows. [Pg.27]

Kinetic analysis of the data obtained in differential reactors is straightforward. One may assume that rates arc directly measured for average concentrations between the inlet and the outlet composition. Kinetic analysis of the data produced in integral reactors is more difficult, as balance equations can rarely be solved analytically. The kinetic analysis requires numerical integration of balance equations in combination with non-linear regression techniques and thus it requires the use of computers. [Pg.297]

Fig. 34. Arrhenius plot of In k versus 1/T for PSS-doped [Fe(6-Mepy)2(py)tren](CI04)2 for the temperature range 50 to 300 K. Here k is the relaxation rate constant, the straight line representing a least squares fit of the 150-300 K data producing AE = 823 cm". The insert shows k versus T between 4.2 and 50 K. According to Ref. [138]... Fig. 34. Arrhenius plot of In k versus 1/T for PSS-doped [Fe(6-Mepy)2(py)tren](CI04)2 for the temperature range 50 to 300 K. Here k is the relaxation rate constant, the straight line representing a least squares fit of the 150-300 K data producing AE = 823 cm". The insert shows k versus T between 4.2 and 50 K. According to Ref. [138]...
Similarly, some INAA data contributed to the derivation of a reference value for Ba in SDO-i were biased high by an interference from Ru (Wandless 1993). The Ru is a fission product of U, whose concentration of 40 qg/g is relatively high in SDO-1. In this case, no appropriate reference sample was available for analysis to control the SDO-1 results the interference was identified through the disagreement between INAA data and data produced using XRF and ICP-AES methods on the same sample. A bias-free method again resulted when analysis of an atypical type led to detection of a rarely encountered but sizeable spectral overlap. Once identified, correction was straightforward. [Pg.224]

Reported data should achieve a clear, purpose-oriented level of accuracy and precision, especially when data produced by several laboratories often needs to be compared as part of a decision process. It has become accepted by more and more analysts that to overcome differences between national standards and specifications and measurement procedures or to make Total Quality Management (TQM) an achievable reality, freely available and internationally agreed points of reference are needed. Therefore RMs and CRMs must be easily available indeed the availability of reference materials has been described as an issue of strategic importance to the EU (Maier et al. 1997). [Pg.256]

The purpose of stability testing is to assess the effects of temperature, humidity, light, and other environmental factors on the quality of a drug substance or product. The data produced are used to establish storage conditions, retest periods, shelf loss, and to justify overages included in products for stability reasons. The most useful equation relating temperature and reaction rate is the Arrhenius equation. This equation (27) may be integrated and rewritten as Eqs. (31) and (32). [Pg.158]

Also, the test procedure (protocol) is fundamental because it allows comparing results from different laboratories and from different experimental sets. Moreover, selected test protocol could affect the interpretation of the results, the information content and its application in the safety evaluation process, as stated by Frazer if the biological system is exposed to a test chemical for 24 h and the endpoint assay is immediately conducted, the data produced would be most relevant to the acute toxicity of the test material. If, on the other hand, the system is exposed to material for 24 h and the system is cultured in the absence of the test material for additional 48 h before the endpoint assay is conducted, the data would be more relevant to recovery from toxicity rather than acute toxicity [7]. [Pg.77]

In summary, using work collected from forward and backward paths greatly improves the accuracy of the estimates, and for the symmetric system studied here eliminates the bias. In our particular example, the cumulant estimators using forward and backward work data produce the most precise free energy estimates, followed by Bennett s optimal estimator. However, this somewhat poorer performance of the optimal estimator is caused in part by the high degree of symmetry of the system studied. [Pg.190]

By standardizing the following parameters, it is possible to improve the quality of data, as well as to increase the opportunities to compare data produced by different laboratories ... [Pg.103]

Normally, time-resolved FT-IR spectroscopy (TRS FT-IR) possesses the same data characteristics. In a typical TRS FT-IR experiment, interferograms are assembled for a specific delay time after the photolysis pulse, and the data produced are normally finer-grained in frequency than in time. This type of experiment is complementary to experiments with fine-grained time information. It is particularly useful where a wide spectral range is necessary and works reasonably well for highly reproducible events which occur on relatively long timescales (fractions of seconds) (83). It is also an appealing system for use on shorter timescales, and it has... [Pg.298]


See other pages where Data producers is mentioned: [Pg.45]    [Pg.504]    [Pg.2]    [Pg.5]    [Pg.458]    [Pg.93]    [Pg.100]    [Pg.1132]    [Pg.231]    [Pg.89]    [Pg.73]    [Pg.62]    [Pg.104]    [Pg.127]    [Pg.74]    [Pg.135]    [Pg.232]    [Pg.106]    [Pg.255]    [Pg.228]    [Pg.245]    [Pg.250]    [Pg.230]    [Pg.185]    [Pg.427]    [Pg.141]    [Pg.332]    [Pg.81]    [Pg.103]    [Pg.420]   
See also in sourсe #XX -- [ Pg.43 ]




SEARCH



Test-data transmission from producer

© 2024 chempedia.info