Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

System test tube

Figure 8.1 A heat bath is a reservoir that holds the system (test tube, in this case) at constant temperature by allowing heat flow in or out, as required. The properties that do not change inside the system are temperature T, voiume V, and particie number N, denoted (T, V, N). The condition for equilibrium inside the test tube is that the Helmhoitz free energy F T, V, N) is at a minimum. Figure 8.1 A heat bath is a reservoir that holds the system (test tube, in this case) at constant temperature by allowing heat flow in or out, as required. The properties that do not change inside the system are temperature T, voiume V, and particie number N, denoted (T, V, N). The condition for equilibrium inside the test tube is that the Helmhoitz free energy F T, V, N) is at a minimum.
Sample Handling System. Venous or capillary blood, urine, and cerebrospinal fluid are specimens routinely used in medical diagnostic testing. Of these biological fluids, the use of venous blood is by far the most prevalent. Collection devices such as syringes and partial vacuum test tubes, eg, Vacutainer, are used to draw ten milliliters or less of venous blood. At collection time, the test tubes are carefully labeled for later identification. [Pg.395]

When a chemical reaction takes place, we consider the substances involved, reactants and products, to be the system. The surroundings include the vessel in which the reaction takes place (test tube, beaker, and so on) and the air or other material in thermal contact with the reaction system. [Pg.198]

In the past, copper was believed to be toxic to most microbiological species. Although this may be true in a test tube under laboratory conditions, it is not generally true in the real world. In this real world, microbial communities excrete slime layers which tend to sequester the copper ions and prevent their contact with the actual microbial cells, Aus preventing the copper from killing the microbes. Many cases of MIC in copper and copper alloys have been documented, especially of heat-exchange tubes, potable water, and fire protection system piping. [Pg.8]

Heat and reflux a 5-g portion of soil sample with 50 mL of methanol-phosphate buffer (pH 7)-water (15 7 28, v/v/v) solvent mixture in a round-bottom flask for 1 h. After cooling, transfer a 10-mL portion of the supernatant to a test-tube and mix with 11 mL of 0.02M H3PO4 solution. Load this solution on to a silica-based SPE cartridge (Analytichem International Clin-Elut 1020) at a flow rate of 1-2 drops per second. Discard this fraction. Elute the analytes with 30 mL of dichloromethane. Concentrate the eluate to dryness with air in a water-bath at a temperature of 40 °C (do not use vacuum). Dissolve the residues in 5mL of HPLC injection solution [900 mL of water - - 50 mL of phosphate buffer (pH 7) 4-50 mL of ACN 4-4 g of TBABr]. Pinal analysis is performed using liquid chromatography/ultraviolet detection (LC/UV) with a three-column switching system. [Pg.593]

In the last several years, on-line extraction systems have become a popular way to deal with the analysis of large numbers of water samples. Vacuum manifolds and computerized SPE stations were all considered to be off-line systems, i.e., the tubes had to be placed in the system rack and the sample eluate collected in a test-tube or other appropriate vessel. Then, the eluted sample had to be collected and the extract concentrated and eventually transferred to an autosampler vial for instrumental analyses. Robotics systems were designed to aid in these steps of sample preparation, but some manual sample manipulation was still required. Operation and programming of the robotic system could be cumbersome and time consuming when changing methods. [Pg.824]

Sample Preparation. Liquid crystalline phases, i.e. cubic and lamellar phases, were prepared by weighing the components in stoppered test tubes or into glass ampoules (which were flame-sealed). Water soluble substances were added to the system as water solutions. The hydrophobic substances were dissolved in ethanol together with MO, and the ethanol was then removed under reduced pressure. The mixing of water and MO solutions were made at about 40 C, by adding the MO solution dropwise. The samples for the in vivo study were made under aseptic conditions. The tubes and ampoules were allowed to equilibrate for typically five days in the dark at room temperature. The phases formed were examined by visual inspection using crossed polarizers. The compositions for all the samples used in this work are given in Tables II and III. [Pg.252]

If tube I clogs, the solid can often be blown out by temporarily raising test tube C, thereby increasing the pressure within the system. [Pg.26]

This definition excludes all systems which do not have a spatial boundary to their synthetic machinery, for example pure RNA replication. The walls of a test tube or the banks of a warm, little pond 1 cannot be included as boundaries in the sense of definition four. [Pg.15]

The search for life in the cosmos requires a generalised, universal definition of life. This must take into account the properties of systems ranging from viruses, prions, denucleated cells or endospores to life in a test tube, computer viruses or even to robots which are capable of self-replication. [Pg.15]

Later articles dealt with further elaboration of ideas on the driving forces which would have led to the formation of higher aggregates from RNA and amino acids. As had been suggested 20 years earlier, these processes could have taken place in rock pores and could have been driven by hydration and dehydration phases (Kuhn and Waser, 1994). The tiny pores in rocks act as minute test tubes, so optimal compositions could have been determined and replicated using many millions of systems. According to this model, none of the synthetic processes taking place would have required the presence of protein enzymes (see also Lahav, 1999). Just as other... [Pg.230]

EIA systems take advantage of the extreme specificity and affinity with which antibodies bind antigens which stimulated their initial production, coupled to the catalytic efficiency of enzymes, which facilitates signal amplification as well as straightforward detection and quantification. In most such systems, the antibody is immobilized on the internal walls of the wells in a multi-well microtitre plate, which therefore serves as collection of reaction mini-test tubes. [Pg.177]

All ancillary reagents used in the LAL assay system (e.g. WFI, test tubes, pipette tips for liquid transfer, etc.) must obviously be endotoxin free. Such items can be rendered endotoxin free by heat. Its heat-stable nature, however, renders very vigorous heating necessary in order to destroy contaminant endotoxin. A single autoclave cycle is insufficient, with total destruction requiring three consecutive autoclave cycles. Dry heat may also be used (180 °C for 3 h or 240 °C for 1 h). [Pg.194]

Blank, calibrator, control, and patient whole-blood samples (50 /iL) were transferred into 1.5 mL conical test tubes, mixed with 100 /xL of the IS, vortexed for 10 sec, and centrifuged at 13,000 g for 5 min. Twenty-five microliters of supernatant were injected onto a Cohesive Technologies Cyclone polymeric turbulent flow column (50 x 1 mm, 50 /flushed with a mixture of methanol and water (10 90 v/v) at a flow of 5 mL/min. Column switching from the TFC to HPLC systems was via a Cohesive Technologies system. The analytical column was a Phenomenex Phenyl-Hexyl-RP (50 x 2.1 mm, 5 /.mi). The mobile phase consisted of methanol and ammonium acetate buffer (97 3 v/v). The buffer was 10mM ammonium acetate containing 0.1% v/v acetic acid. The flow rate was 0.6 mL/min. [Pg.309]

Recently there has been an increasing interest in self-oscillatory phenomena and also in formation of spatio-temporal structure, accompanied by the rapid development of theory concerning dynamics of such systems under nonlinear, nonequilibrium conditions. The discovery of model chemical reactions to produce self-oscillations and spatio-temporal structures has accelerated the studies on nonlinear dynamics in chemistry. The Belousov-Zhabotinskii(B-Z) reaction is the most famous among such types of oscillatory chemical reactions, and has been studied most frequently during the past couple of decades [1,2]. The B-Z reaction has attracted much interest from scientists with various discipline, because in this reaction, the rhythmic change between oxidation and reduction states can be easily observed in a test tube. As the reproducibility of the amplitude, period and some other experimental measures is rather high under a found condition, the mechanism of the B-Z reaction has been almost fully understood until now. The most important step in the induction of oscillations is the existence of auto-catalytic process in the reaction network. [Pg.222]

The Zymark robotic laboratory automation system Although detail procedures differ in each laboratory, the basic elements of binding and enzyme assays are similar. The generalized procedure shown in Table 1.10 highlights the common steps and indicates which Zymate laboratory systems are required. These procedures are performed using common laboratory glassware such as test tubes or in multiple tube devices such as microtitre plates. [Pg.93]

Experiments involving the release of radioactive carbon dioxide from MSMA-14C treated soils were conducted in a system consisting of two test tubes connected in series. One tube contained 5g of treated soil (at 10 and lOOppm of monosodium methane arsenic acid carbon dioxide while a second tube contained a trapping mixture, 2-methoxyethanol and monoethanolamine (7-10, v/v). Carbon dioxide-free air was passed over the soil and metabolic 14CO was collected in the trapping solution. The soils studied were Sharkey cldy, Hagerstown silty clay loam, Cecil sandy loam, and Dundee silty clay loam. All soils were initially adjusted to field capacity and maintained at 28-30°C the evolved 14CO was sampled periodically. Some properties of these soils are shown in Tabfe 13.1. [Pg.382]

A number of potential users, such as the printing industry, are interested in the solvent fastness not only of a pigment but of an entire pigment-vehicle system. Standardized tests are available. A proof print of a certain size is placed inside a test tube and allowed to remain in the target solvent at 20°C for 5 minutes. The change in solvent color is determined and the print dried and compared with an untreated specimen. Standard solvents [14] are ethanol or the following mixture ... [Pg.57]

Instruments in which each test is performed in its own container or slide are known as discrete analysers, in contrast to flow analysers in which the samples follow each other through the same system of tubing. All discrete analysers have a common basic design incorporating a pipetting system, a photometric detector and a microprocessor. A development of the single test instrument is the parallel fast analyser, which analyses several samples simultaneously but for only one constituent. However, the change-over from one analytical procedure to another is quick and simple. [Pg.212]

Enzyme labels are usually associated with solid-phase antibodies in the technique known as enzyme-linked immunosorbent assay (ELISA). There are several variants of this technique employing both competitive and non-competitive systems. However it is best used in combination with two monoclonal antibodies in the two-site format in which an excess of antibody is bound to a solid phase such as a test-tube or microtitre plate the test antigen is then added and is largely sequestered by the antibody (Figure 7.12). After washing... [Pg.249]

CBL system graphing calculator ChemBio program Vernier pressure sensor link cable CBL-DIN cable test tube with 5 rubber-stopper assembly... [Pg.94]

What objective individual could believe that this extremely diverse system, ongoing in various cells in the animal body, could be replicated in test tube or computer experiments ... [Pg.317]

How can anyone believe that the whole animal body system can be mimicked in a test tube or a computer ... [Pg.318]


See other pages where System test tube is mentioned: [Pg.592]    [Pg.16]    [Pg.104]    [Pg.396]    [Pg.172]    [Pg.104]    [Pg.177]    [Pg.112]    [Pg.198]    [Pg.625]    [Pg.1156]    [Pg.75]    [Pg.258]    [Pg.25]    [Pg.224]    [Pg.152]    [Pg.49]    [Pg.62]    [Pg.62]    [Pg.35]    [Pg.364]    [Pg.417]    [Pg.375]    [Pg.54]    [Pg.4]    [Pg.5]    [Pg.42]    [Pg.317]   
See also in sourсe #XX -- [ Pg.132 ]




SEARCH



System testing

Test systems

Test tubes

Tube system

Tubing system

© 2024 chempedia.info