Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Change-over

Figure 6.6 illustrates what happens to the cost of the system as the relative position of the composite curves is changed over a range of values of AT ir,. When the curves just touch, there is no driving force for heat transfer at one point in the process, which would require an... [Pg.165]

The N/G ratio is usually not oonstant across a reservoir and may change over quite short distances from 1.0 (100% reservoir) to 0.0 (no reservoir) in some depositional environments. Reservoirs with a low or unpredictable N/G ratios often require large numbers of wells to access reserves and are therefore more expensive to develop. [Pg.145]

Although a single project manager may direct activities throughout a project life, he or she will normally be supported by a project team whose oomposition should reflect the type of project and the experience levels of both company and contractor personnel. The make up and size of the team may change over the life of a project to match the prevailing activity levels in each particular section of the project. [Pg.295]

Sample scan data is a good way to archive the results of an inspection. The inspection could be re-visited later to see how the eddy-current response has changed over time. Random audits of the quality of inspection detection could be monitored. The inspection could also be reviewed if new information becomes known, say from inspection conducted using alternate methods. [Pg.1020]

The gas has to be dilute because the collision cylinders are assumed not to overlap, and also because collisions between more than two particles are neglected. Also it is assumed that/hardly changes over 8r so that the distribution fimctions for both colliding particles can be taken at the same position r. [Pg.678]

Micellization is a second-order or continuous type phase transition. Therefore, one observes continuous changes over the course of micelle fonnation. Many experimental teclmiques are particularly well suited for examining properties of micelles and micellar solutions. Important micellar properties include micelle size and aggregation number, self-diffusion coefficient, molecular packing of surfactant in the micelle, extent of surfactant ionization and counterion binding affinity, micelle collision rates, and many others. [Pg.2581]

In three-dimensional (3D) applications the overall phase change over a cycle may therefore be expressed as a surface integral, analogous to Eq. (43), namely. [Pg.17]

A lustrous metal has the heat capacities as a function of temperature shown in Table 1-4 where the integers are temperatures and the floating point numbers (numbers with decimal points) are heat capacities. Print the curve of Cp vs. T and Cp/T vs. T and determine the entropy of the metal at 298 K assuming no phase changes over the interval [0, 298]. Use as many of the methods described above as feasible. If you do not have a plotting program, draw the curves by hand. Scan a table of standard entropy values and decide what the metal might he. [Pg.29]

As mentioned above, the preferred computational methods for modeling crystals have changed over the years. Below is a list of basis function schemes, with the most often used appearing first ... [Pg.269]

There exists a critical temperature for this behavior above which Fig. 8.2b changes over to Fig. 8.2a, which describes miscibility in all proportions. [Pg.532]

The failure rate changes over the lifetime of a population of devices. An example of a failure-rate vs product-life curve is shown in Figure 9 where only three basic causes of failure are present. The quaUty-, stress-, and wearout-related failure rates sum to produce the overall failure rate over product life. The initial decreasing failure rate is termed infant mortaUty and is due to the early failure of substandard products. Latent material defects, poor assembly methods, and poor quaUty control can contribute to an initial high failure rate. A short period of in-plant product testing, termed bum-in, is used by manufacturers to eliminate these early failures from the consumer market. [Pg.9]

Thermal imaging is sensitive to iafrared radiation that detects temperature changes over the surface of a part when heat has been appHed. Thermal diffusion ia a soHd is affected by variatioa ia composition or by the preseace of cracks, voids, delamiaatioas, etc the effects are detected by surface temperature changes. Defects cannot be detected if their depth below the surface is more than two to three times their diameter. Nondestmctive testing has been primarily used for composites and analysis of adhesive bonds or welds. Several studies are documented ia the Hterature (322—327). [Pg.156]

Has enough flexibiUty been built into the overall condensing turbine system (The balance changes over the history of a unit as a process evolves, generally in the direction of less condensing demand.)... [Pg.93]

Master curves can be used to predict creep resistance, embrittlement, and other property changes over time at a given temperature, or the time it takes for the modulus or some other parameter to reach a critical value. For example, a mbber hose may burst or crack if its modulus exceeds a certain level, or an elastomeric mount may fail if creep is excessive. The time it takes to reach the critical value at a given temperature can be deduced from the master curve. Frequency-based master curves can be used to predict impact behavior or the damping abiUty of materials being considered for sound or vibration deadening. The theory, constmction, and use of master curves have been discussed (145,242,271,277,278,299,300). [Pg.202]

Indicators can determine if uniform steam penetration has been achieved during a Bowie Dick-type test. Produced in the form of sheets (23 X 30 cm), chemical indicators are capable of uniform color change over their entire surface when exposed to pure saturated steam under test conditions. Nonuniform color development is an indication of failure of the test. U.S. and international stands for the performance and accuracy of chemical indicators have been pubHshed (13,14). [Pg.408]

Sulfate concentration in streams and changes over time are discussed later in this article as one of the principal indices of human influences on stream water composition. Also, it will be shown that differences and similarities ia sulfate yields help in attaining a reasonable perspective on the importance of various hydrologic and geochemical characteristics of individual drainage systems. [Pg.201]

Lysol consists of a mixture of the three cresol isomers solubilized using a soap prepared from linseed oil and potassium hydroxide, to form a clear solution on dilution. Most vegetative pathogens, including mycobacteria, are killed in 15 minutes by 0.3—0.6% lysol. Lysol has a phenol coefficient of 2. Bacterial spores are very resistant. Lysol is also the name of a proprietary product, the formula of which has changed over the years other phenols have been substituted for the cresols. [Pg.126]


See other pages where Change-over is mentioned: [Pg.217]    [Pg.107]    [Pg.153]    [Pg.336]    [Pg.341]    [Pg.548]    [Pg.495]    [Pg.540]    [Pg.268]    [Pg.24]    [Pg.78]    [Pg.131]    [Pg.462]    [Pg.479]    [Pg.248]    [Pg.375]    [Pg.28]    [Pg.107]    [Pg.353]    [Pg.30]    [Pg.406]    [Pg.115]    [Pg.131]    [Pg.45]    [Pg.209]    [Pg.176]    [Pg.182]    [Pg.288]    [Pg.460]    [Pg.203]    [Pg.319]    [Pg.461]    [Pg.336]    [Pg.181]   
See also in sourсe #XX -- [ Pg.5 , Pg.40 , Pg.56 ]

See also in sourсe #XX -- [ Pg.23 ]




SEARCH



© 2024 chempedia.info