Sampling period

In practice, only a limited number of views are available the scanned sector is typically 180 or 360°, and the angular increment 2°. Moreover the frequency band-width of the employed pulses is very limited, typically one octave. The resolving power of the system is then limited. A typical numerical signal is composed of 1024 samples at a sampling period of 50 nsec. [Pg.746]

Fig. 1. Sample period options, where each letter, A through E, represents a separate sample. Fig. 1. Sample period options, where each letter, A through E, represents a separate sample.
Da.ta. Ana.lysls. First, the raw data must be converted to concentrations over an appropriate time span. When sample periods do not correspond to the averaging time of the exposure limit, some assumptions must be made about unsampled periods. It may be necessary to test the impact of various assumptions on the final decision. Next, some test statistics (confidence limit, etc) (Fig. 3) are calculated and compared to a test criteria to make an inference about a hypotheses. [Pg.109]

The MPC control problem illustrated in Eqs. (8-66) to (8-71) contains a variety of design parameters model horizon N, prediction horizon p, control horizon m, weighting factors Wj, move suppression factor 6, the constraint limits Bj, Q, and Dj, and the sampling period At. Some of these parameters can be used to tune the MPC strategy, notably the move suppression faclor 6, but details remain largely proprietary. One commercial controller, Honeywell s RMPCT (Robust Multivariable Predictive Control Technology), provides default tuning parameters based on the dynamic process model and the model uncertainty. [Pg.741]

A one-hour sampling period is generally required for this method. Samphng periods are specified by the apphcable standard e.g., standards for petroleum refineries require sampling for one hour or more. [Pg.2202]

A particulate sample was found to contain 350 mg m . The COj during the sampling period averaged 7.2%. If the exhaust gas flow was 2000 m min, what would be the particulate loading in both milligrams per cubic meter and kilograms per hour, corrected to 12% C O A... [Pg.553]

Ceiling TLV(C) - the eoneentration that should not be exeeeded during any part of the working exposure. If instantaneous monitoring is not possible then the TLV(C) ean be assessed over a 15 min sampling period, exeept for those substanees that may eause immediate initation when exposures are short. [Pg.82]

Prepare a blank(s) during the sample period for each type of sample collected. For any given analysis, one blank will suffice for up to 20 samples collected. These blanks may include opened but unused charcoal tubes, and so forth. [Pg.241]

Before removing the pump at the end of the sample period, check the flow rate to ensure that the rotameter bail is still at the calibrated mark (if there is a pump rotameter). If the ball is no longer at the mark, record the pump rotameter reading. [Pg.241]

In some instances, it will be necessary to add additional reagent during the sampling period to prevent the amount of reagent from dropping below one-half of the original amount. [Pg.244]

Because of the limited adsorption capacity of the tube, the sampling period should not exceed 15 to 30 minutes. The time will depend to some degree on the expertise of the observer, since high concentrations of solvent vapors could saturate the first charcoal section in a few minutes. [Pg.277]

The sampling period and interval of sampling are related to concemrarion patterns and to the method of analysis used. [Pg.371]

High-volume sampler A device used for extracting particulates from the air for analysis that requires a shorter. sampling period than a low-volume sampler. [Pg.1448]

Hydrocortisone microspheres (108,109) and films (110) based on poly(lactic acid) have been investigated. A cage implant technique was used to study the performance of monolithic poly (DL-lactide) films loaded with hydrocortisone acetate (110). Films 1.5 x 0.6 cm were inserted into titanium wire-mesh cages 3.5 x 1.0 cm. The cages were implanted in the backs of rats and the inflammatory exudate was sampled periodically. The white cell concentration in the samples was lower than that of controls at all times during the 21-day test. [Pg.24]

These two methods produce different release profiles in vitro. Figure 5 demonstrates the release kinetics of BCNU from wafers loaded with 2.5% BCNU pressed from materials produced using these two methods. The wafers containing tritiated BCNU were placed into beakers containing 200-ml aliquots of 0.1 M phosphate buffer, pH 7.4, which were placed in a shaking water bath maintained at 37 C. The shaking rate was 20 cycles/min to avoid mechanical disruption of the wafers. The supernatant fluid was sampled periodically, and the BCNU released was determined by liquid scintillation spectrometry. The BCNU was completely released from the wafers prepared by the trituration method within the first 72 hr, whereas it took just about twice as long for the BCNU to be released from wafers... [Pg.51]

Figure 4.8 Noradrenaline concentration in dialysis samples from probes implanted in the rat frontal cortex. Spontaneous efflux of noradrenaline is stable throughout a 4h sampling period ( extended basals ) but is increased markedly when either the noradrenaline reuptake inhibitor, desipramine (5 pM), or the a2-adrenoceptor antagonist, atipamezole (0.5 pM), is infused into the extracellular fluid via the microdialysis probe ( retrodialysis )... Figure 4.8 Noradrenaline concentration in dialysis samples from probes implanted in the rat frontal cortex. Spontaneous efflux of noradrenaline is stable throughout a 4h sampling period ( extended basals ) but is increased markedly when either the noradrenaline reuptake inhibitor, desipramine (5 pM), or the a2-adrenoceptor antagonist, atipamezole (0.5 pM), is infused into the extracellular fluid via the microdialysis probe ( retrodialysis )...
Once the target number of samples was defined, the frequency of collection and the number of samples to be collected on each collection date were determined, based on an overall total sampling period of 1 year. The sampling plan specified collection every other week, primarily to accommodate the workload at the analytical laboratories. Sampling had to occur early in the week to preclude problems with shipping samples over the weekend. With these considerations in place, specific dates for collection of commodity samples could readily be set. [Pg.238]


See other pages where Sampling period is mentioned: [Pg.225]    [Pg.234]    [Pg.80]    [Pg.80]    [Pg.270]    [Pg.107]    [Pg.75]    [Pg.379]    [Pg.1428]    [Pg.300]    [Pg.300]    [Pg.702]    [Pg.198]    [Pg.329]    [Pg.252]    [Pg.263]    [Pg.367]    [Pg.1289]    [Pg.357]    [Pg.92]    [Pg.760]    [Pg.1054]    [Pg.335]    [Pg.141]    [Pg.225]    [Pg.217]    [Pg.181]    [Pg.239]    [Pg.329]    [Pg.5]    [Pg.180]   
See also in sourсe #XX -- [ Pg.198 ]

See also in sourсe #XX -- [ Pg.22 ]

See also in sourсe #XX -- [ Pg.643 ]




SEARCH



Noise sampling period

Period Discrimination of Ancient Samples

Period, dynamics sampling

Sampling time period

© 2024 chempedia.info