Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Rack system

Hew -H/ffer Christensen Jar. (See Figure 4-173 [57A].) This is a mechanical drilling jar with firing racks system applied. Its jar force is constant regardless of torque applied. [Pg.818]

The solution to this would require constructional details of the proposed racking system and each pallet will now require an area of about 1.400 X 1.075 m. Height clearance must be allowed for each tier - a total of 1.600 m each pallet high. Also, it is not possible for a fork-lift truck to reach three pallets deep into a stack, so the arrangement would now be two deep along the sides and four-deep... [Pg.171]

Sharp, G. G., Amirhosseini, M. M., and Shamanna, S. K. (1994), Analysis of a Company s Order Kcking Rack System, MHRC-OP-94-01, School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta. [Pg.2109]

Utility refers to functionality or convenience provided by the package for one or more entities involved in prodnct manufacture, distribution, or use. For example, cooking sprays in aerosol cans produce a lubricating effect in a frying pan with mnch less prodnct than wonld be required without the aerosol. The carton on a tnbe of toothpaste permits the retailer to stack the tubes on the shelf without them rolling off. The metal edge on the carton of plastic wrap permits the consumer to tear off the desired amount of the product. Stretch wrap and a pallet permit a load of goods to be handled by a forklift and stored in a rack system in a warehonse. [Pg.142]

To establish remote maintenance concept with rack system, key technologies such as bilateral servo manipulator (BSM), roll-in type rack, remote connector bank, and remote sampling system have been developed. [Pg.170]

A French manufacturer, Tacussel, produced several electroanalytical systems. Rack systems, based on analog electronics and composed of several different units, were able to perform a wide assortment of electrochemical techniques. The UAP M pulse polarography unit was employed in the PRO 3 Electroanalytical System, which was referred to as VOCTAN (volt, current and time could be controlled or measured). The UAP unit sold for 8970 in 1973, the total system, including cell stand, for 21,280. Pulse amplitudes between 1 mV and 1000 mV could be applied from 1 ms to 10 s. The current was sampled for an adjustable portion (Oyt to 100%) of the pulse duration. Full scale currents ranged from 1.25 nA to 5 mA. Drop times as long as 100 s could be employed. A self-contained pulse polarographic instrument, the Tacussel PRG 5, sold for 3990 in 1973. This instrument could be used for dc, np and dp polarography. [Pg.393]

To develop a maintenance program designed to recognize weakness in the rack system in order to prevent a structural collapse. [bold emphasis added]... [Pg.352]

There are many designs of racks used for storage. The most common are flow rack system, single deep rack, double deep rack, and push back rack. Some other storage systems are carton flow rack, cantilever rack and drive-in rack. Flow racks use rails on an incline that permit loads to move by gravity from the loading bay to... [Pg.138]

The goal of remote circuit breaker racking systems and remote circuit breaker switching systems is to reduce the number of easiiy preventabie injuries and protect workers from eiectricai arc hazards in the workpiace. The safest and iowest-cost method of truiy protecting your workers operating on energized equipment is to increase working distance. [Pg.22]

Remote circuit breaker racking enables service personnel to stand outside the arc flash protection boundary while racking low and medium voltage draw-out circuit breakers, reducing the need for a full-body arc flash hazard suit due to the increased distance the remote racking system offers. [Pg.23]

Prohibit overloading of any pallet positions and of the overall racking system. [Pg.50]

Professionals can evaluate current racking systems and provide upgrades and improvements to... [Pg.50]

Guiher, William T. Designing Rack Systems. Plant Engineering. September 1997, pp. 120-124. [Pg.55]

Are the heaviest products stored on the floor or lower levels and toward the middle of the rack system ANSI/RMI... [Pg.474]


See other pages where Rack system is mentioned: [Pg.1975]    [Pg.1979]    [Pg.817]    [Pg.39]    [Pg.387]    [Pg.41]    [Pg.1733]    [Pg.1737]    [Pg.2917]    [Pg.286]    [Pg.129]    [Pg.1979]    [Pg.1983]    [Pg.2089]    [Pg.2106]    [Pg.341]    [Pg.224]    [Pg.351]    [Pg.351]    [Pg.354]    [Pg.354]    [Pg.42]    [Pg.106]    [Pg.223]    [Pg.23]    [Pg.23]    [Pg.623]    [Pg.623]   
See also in sourсe #XX -- [ Pg.33 , Pg.38 , Pg.180 ]




SEARCH



Protection systems loading racks

Racking

Racks