Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Surface analytical procedure

AFM Particles adhered or dispersed to a substrate Surface analytical procedure [96-98]... [Pg.152]

TEMNMR Thin and vacuum resistatic electron transparent samples Solid powder or liquid samples Surface water, sea water, activated sludge Surface analytical procedure [96,99,100] [41,35,91]... [Pg.152]

Silica gel, per se, is not so frequently used in LC as the reversed phases or the bonded phases, because silica separates substances largely by polar interactions with the silanol groups on the silica surface. In contrast, the reversed and bonded phases separate material largely by interactions with the dispersive components of the solute. As the dispersive character of substances, in general, vary more subtly than does their polar character, the reversed and bonded phases are usually preferred. In addition, silica has a significant solubility in many solvents, particularly aqueous solvents and, thus, silica columns can be less stable than those packed with bonded phases. The analytical procedure can be a little more complex and costly with silica gel columns as, in general, a wider variety of more expensive solvents are required. Reversed and bonded phases utilize blended solvents such as hexane/ethanol, methanol/water or acetonitrile/water mixtures as the mobile phase and, consequently, are considerably more economical. Nevertheless, silica gel has certain areas of application for which it is particularly useful and is very effective for separating polarizable substances such as the polynuclear aromatic hydrocarbons and substances... [Pg.93]

During the past twenty or so years numerous sophisticated surface analytical techniques have been successfully employed to investigate and understand the nature of bonding surfaces and their interaction with the environment. Some of these, e.g., HR-SEM and XPS have been mentioned above, with details of these and many more techniques covered in Chapter 6. In this section emphasis will be placed on those somewhat less sophisticated techniques that are employed in or in close conjunction with bond shops. What they lack in sophistication they often make up for in the ability to quickly and cheaply evaluate whether problems such as surface contamination or out-of-spec surface treatment procedures are... [Pg.994]

Ultrafiltration utilizes membrane filters with small pore sizes ranging from O.OlS t to in order to collect small particles, to separate small particle sizes, or to obtain particle-free solutions for a variety of applications. Membrane filters are characterized by a smallness and uniformity of pore size difficult to achieve with cellulosic filters. They are further characterized by thinness, strength, flexibility, low absorption and adsorption, and a flat surface texture. These properties are useful for a variety of analytical procedures. In the analytical laboratory, ultrafiltration is especially useful for gravimetric analysis, optical microscopy, and X-ray fluorescence studies. [Pg.347]

Rhodium-platinum alloys containing up to 40% Rh are used in the form of wire or ribbon in electrical resistance windings for furnaces to operate continuously at temperatures up to 1 750°C. Such windings are usually completely embedded in a layer of high-grade alumina cement or flame-sprayed alumina to prevent volatilisation losses from the metal due to the free circulation of air over its surface. Furnaces of this type are widely employed for steel analysis, ash fusions and other high-temperature analytical procedures. [Pg.941]

The method using GC/MS with selected ion monitoring (SIM) in the electron ionization (El) mode can determine concentrations of alachlor, acetochlor, and metolachlor and other major corn herbicides in raw and finished surface water and groundwater samples. This GC/MS method eliminates interferences and provides similar sensitivity and superior specificity compared with conventional methods such as GC/ECD or GC/NPD, eliminating the need for a confirmatory method by collection of data on numerous ions simultaneously. If there are interferences with the quantitation ion, a confirmation ion is substituted for quantitation purposes. Deuterated analogs of each analyte may be used as internal standards, which compensate for matrix effects and allow for the correction of losses that occur during the analytical procedure. A known amount of the deuterium-labeled compound, which is an ideal internal standard because its chemical and physical properties are essentially identical with those of the unlabeled compound, is carried through the analytical procedure. SPE is required to concentrate the water samples before analysis to determine concentrations reliably at or below 0.05 qg (ppb) and to recover/extract the various analytes from the water samples into a suitable solvent for GC analysis. [Pg.349]

The method for chloroacetanilide soil metabolites in water determines concentrations of ethanesulfonic acid (ESA) and oxanilic acid (OXA) metabolites of alachlor, acetochlor, and metolachlor in surface water and groundwater samples by direct aqueous injection LC/MS/MS. After injection, compounds are separated by reversed-phase HPLC and introduced into the mass spectrometer with a TurboIonSpray atmospheric pressure ionization (API) interface. Using direct aqueous injection without prior SPE and/or concentration minimizes losses and greatly simplifies the analytical procedure. Standard addition experiments can be used to check for matrix effects. With multiple-reaction monitoring in the negative electrospray ionization mode, LC/MS/MS provides superior specificity and sensitivity compared with conventional liquid chromatography/mass spectrometry (LC/MS) or liquid chromatography/ultraviolet detection (LC/UV), and the need for a confirmatory method is eliminated. In summary,... [Pg.349]

Brandt [200] has extracted tri(nonylphenyl) phosphite (TNPP) from a styrene-butadiene polymer using iso-octane. Brown [211] has reported US extraction of acrylic acid monomer from polyacrylates. Ultrasonication was also shown to be a fast and efficient extraction method for organophosphate ester flame retardants and plasticisers [212]. Greenpeace [213] has recently reported the concentration of phthalate esters in 72 toys (mostly made in China) using shaking and sonication extraction methods. Extraction and analytical procedures were carefully quality controlled. QC procedures and acceptance criteria were based on USEPA method 606 for the analysis of phthalates in water samples [214]. Extraction efficiency was tested by spiking blank matrix and by standard addition to phthalate-containing samples. For removal of fatty acids from the surface of EVA pellets a lmin ultrasonic bath treatment in isopropanol is sufficient [215]. It has been noticed that the experimental ultrasonic extraction conditions are often ill defined and do not allow independent verification. [Pg.80]

The many technical factors involved in desizing and the need for economy and environmental accountability emphasise the importance of monitoring and analysis. However, only a brief outline can be given here. A review of analytical procedures and simple laboratory methods for size determination is available [193]. Methods are given for size determination directly on the fibre surface, for the extraction of components of low molecular mass and for their subsequent estimation in solution. [Pg.108]

By today s standards of surface preparation, Will s procedures for surface preparation were crude, the surface structures were not characterized by use of surface analytical instrumentation (Which was neither widely available nor well developed at that time), and he employed extensive potentiodynamic cycling through the "oxide" formation potential region prior to reporting the quasi-steady state voltammetry curve, i.e., the potentiodynamic I-V curve. The studies employing surface analytical methods made a decade or more later were... [Pg.37]

An analytical procedure that quantifies the total AE concentration resolved by alkyl chain length for various environmental matrices (influent, effluent, and river water) was developed by Di Corcia et al. [41]. The method utilises a reverse-phase column to extract and concentrate AE from surface waters and wastewaters and utilises strong anionic and cationic exchange columns to remove potential interferences. Samples are passed through the RP extraction column (Ci). AE and potential anionic and cationic interferences are eluted from the Ci column and passed directly through the SAX and SCX. The SAX and SCX columns retain anionic and cationic materials while non-ionic AE are not retained. Recovery of AE from influent, treatment plant effluent, and river water is quantitative (65—102%) over a range of concentrations for all matrices. [Pg.431]

Trends in mass spectrometry focus on the improvement of instrumentation, of several techniques in order to minimize sample volume, to improve sensitivity and to reduce detection limits. This is combined with increasing the speed of several analyses, with automation of analytical procedures and subsequently reducing the price of analysis. A minimizing of sample volumes means a reduction of waste volume with the aim of developing green chemistry . Furthermore, new analytical techniques involve a development of quantification procedures to improve the accuracy and precision of analytical data. Special attention in future will be given to the development of hyphenated mass spectrometric techniques for speciation analysis and of surface analytical techniques with improved lateral resolution in the nm scale range. [Pg.6]

An analytical procedure has been proposed for precise uranium isotope ratio measurements in a thin uranium layer on a biological surface by LA-ICP-MS using a cooled laser ablation chamber.125 One drop of uranium isotope standard reference materials NIST, 350, NIST 930, of our isotopic laboratory standard CCLU 500 (20p.l, U concentration 200 ng 1) and of uranium with natural isotopic pattern were deposited on the leaf surface and analyzed by LA-ICP-MS at well defined laser crater diameters of 10, 15, 25 and 50 p.m. A precision for measurements of isotope ratios in the range of 2.1-1.0% for 235U/238U in selected isotope standards was observed whereby the precision and the accuracy of isotope ratios compared to the non-cooled laser ablation chamber was improved.125... [Pg.234]

The surface of a solid sample interacts with its environment and can be changed, for instance by oxidation or due to corrosion, but surface changes can occur due to ion implantation, deposition of thick or thin films or epitaxially grown layers.91 There has been a tremendous growth in the application of surface analytical methods in the last decades. Powerful surface analysis procedures are required for the characterization of surface changes, of contamination of sample surfaces, characterization of layers and layered systems, grain boundaries, interfaces and diffusion processes, but also for process control and optimization of several film preparation procedures. [Pg.277]

Depth profiles of matrix elements on Mn- and Co-perovskite layers of fuel cathodes have been measured by LA-ICP-MS in comparison to other well established surface analytical techniques (e.g., SEM-EDX).118 On perovskite layers at a spatial resolution of 100p.m a depth resolution of 100-200 nm was obtained by LA-ICP-MS. The advantages of LA-ICP-MS in comparison to other surface analytical techniques (such as XPS, AES, SIMS, SNMS, GD-OES, GDMS and SEM-EDX) are the speed, flexibility and relatively low detection limits with an easy calibration procedure. In addition, thick oxide layers can be analyzed directly and no charging effects are observed in the analysis of non-conducting thick layers. [Pg.283]

HaS or HI, so as to form lead carbonate, sulfide or iodide oidy on the surface without penetration into the crystal (Ref 22). This treatment will unquestionably reduce the efficiency of LA because it will be contaminated by inert materials l)Solubiliry of LA in water or in 50% alcohol was detd as described in item VII F tinder Lead Azide Plant Analytical Procedures In addn to above listed tests, the various LA s were loaded in M47 caps as intermediate chges together with NOLNo 130 as a primary chge and RDX as a base chge and subjected to the following tests given in the Purchase Description PA-PD-202, with Rev 1 dated 30 Sept 1952 and Amend 1 dated 27 Jan 1953 ... [Pg.562]


See other pages where Surface analytical procedure is mentioned: [Pg.519]    [Pg.742]    [Pg.519]    [Pg.742]    [Pg.1828]    [Pg.202]    [Pg.393]    [Pg.88]    [Pg.269]    [Pg.217]    [Pg.518]    [Pg.589]    [Pg.88]    [Pg.175]    [Pg.218]    [Pg.502]    [Pg.243]    [Pg.537]    [Pg.225]    [Pg.195]    [Pg.469]    [Pg.11]    [Pg.44]    [Pg.86]    [Pg.195]    [Pg.272]    [Pg.435]    [Pg.15]    [Pg.26]    [Pg.537]    [Pg.196]    [Pg.272]    [Pg.285]    [Pg.286]   
See also in sourсe #XX -- [ Pg.35 ]




SEARCH



Analytic Procedures

Analytical procedures

Analytical procedures solids and surfaces

Surface analytics

© 2024 chempedia.info